ETC RN1S23L50PO

Solid State Relays
System Monitoring Relay (SOLITRON)
Type RN1S ....... (Sense Relay)
•
•
•
•
•
•
•
•
System (line and load) monitoring relay
Rated operational current: 30 A and 50 AACrms
Zero switching for heating and motor applications
Rated operational voltage: 230, 400 and 480 VACrms
Transient overvoltage protection built-in
Alarm output signal
LED-indication for alarm and supply/relay ON
DIN-rail mountable
Product Description
Ordering Key
The system monitoring
Solid State Relay (Sense
Relay) provides an alarm
output in the event of a circuit failure. Internal circuits
monitor:
- line voltage
- load current
- correct functioning of the SSR
- SSR input status
Solid State Relay
Number of poles
Rated operational voltage
Control input
Rated operational current
Alarm output type
The relay is designed for
applications where immediate fault detection is required.
A red LED indicates an
alarm, a green LED indicates
DC control supply OK (half
LED light intensity) resp.
relay switched ON (full LED
light intensity).
RN 1S 23 H 30 NO
Type Selection
Rated operational
voltage
Control input
Rated operational
current
Alarm output
type
23: 230 VACrms
40: 400 VACrms
48: 480 VACrms
H: Active high
L: Active low
30: 30 AACrms
50: 50 AACrms
NO: NPN, NO
NC: NPN, NC
PO: PNP, NO
PC: PNP, NC
Selection Guide
Rated
operational
voltage
Alarm
output
type
Rated operational current
30 AACrms
30 AACrms
Active high
Active low
50 AACrms
Active high
50 AACrms
Active low
230 VACrms
NPN, NO
NPN, NC
PNP, NO
PNP, NC
NPN, NO
NPN, NC
PNP, NO
PNP, NC
NPN, NO
NPN, NC
PNP, NO
PNP, NC
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
400 VACrms
480 VACrms
1S23H30NO
1S23H30NC
1S23H30PO
1S23H30PC
1S40H30NO
1S40H30NC
1S40H30PO
1S40H30PC
1S48H30NO
1S48H30NC
1S48H30PO
1S48H30PC
Specifications are subject to change without notice (30.06.1999)
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
RN
1S23L30NO
1S23L30NC
1S23L30PO
1S23L30PC
1S40L30NO
1S40L30NC
1S40L30PO
1S40L30PC
1S48L30NO
1S48L30NC
1S48L30PO
1S48L30PC
1S23H50NO
1S23H50NC
1S23H50PO
1S23H50PC
1S40H50NO
1S40H50NC
1S40H50PO
1S40H50PC
1S48H50NO
1S48H50NC
1S48H50PO
1S48H50PC
1S23L50NO
1S23L50NC
1S23L50PO
1S23L50PC
1S40L50NO
1S40L50NC
1S40L50PO
1S40L50PC
1S48L50NO
1S48L50NC
1S48L50PO
1S48L50PC
1
RN1S .......
General Specifications
Operational voltage range
Non-rep. peak voltage
Varistor voltage
Zero voltage turn-on
Operational frequency range
Power factor
CE-marking (Ext. filter for EN 50081-1 needed)
RN1S23.....
RN1S40.....
RN1S48.....
120 to 265 VAC
800 Vp
275 VAC
≤ 15 V
45 to 65 Hz
≥ 0.5 @ 230 VAC
Yes
150 to 440 VAC
1000 Vp
420 VAC
≤ 15 V
45 to 65 Hz
≥ 0.5 @ 400 VAC
Yes
180 to 530 VAC
1200 Vp
510 VAC
≤ 25 V
45 to 65 Hz
≥ 0.5 @ 480 VAC
Yes
Control Specifications
Supply voltage range
Supply current
Response time pick-up @ 50 Hz
Response time drop-out @ 50 Hz
Active high control input
Pick-up voltage
Drop-out voltage
Input current (Vc = 32 V)
Active low control input
Pick-up voltage
Drop-out voltage
Input current (Vcc = 32 V)
20 to 32 V
≤ 40 mA
≤ 10 ms
≤ 10 ms
Typ. 7 VDC
Typ. 6.8 VDC
≤ 4 mA
PNP alarm output
Alarm output voltage open
Alarm output voltage @ 100 mA
Alarm output current
NPN alarm output
Alarm output voltage open
Alarm output voltage @ 100 mA
Alarm output current
≤ 0 VDC
Vcc - 2 VDC
≤ 100 mA
≤ 32 VDC
2 VDC
≤ 100 mA
Typ. Vcc - 10 VDC
Typ. Vcc - 10 VDC
≤ 4 mA
Output Specifications
RN1S...30..
RN1S...50..
30 Arms
25 Arms
23 Arms
20 Arms
6 Arms
Yes
200 mA
50 Arms
50 Arms
38 Arms
30 Arms
12 Arms
Yes
200 mA
≤ 250 Ap
≤ 600 Ap
< 6 mA
310 A2s
500 V/µs
< 6 mA
1800 A2s
500 V/µs
RN1S23.....
RN1S40.....
RN1S48.....
≥ 50 mA
≤ 20 mA
≥ 50 mA
≤ 20 mA
≥ 50 mA
≤ 20 mA
≥ 120 Vrms
≤ 50 Vrms
≥ 150 Vrms
≤ 80 Vrms
≥ 180 Vrms
≤ 100 Vrms
≤ 100 ms
Will be sensed
≤ 100 ms
Will be sensed
≤ 100 ms
Will be sensed
Rated operational load current
AC 1
@Ta = 30°C
@Ta = 40°C
@Ta = 50°C
@Ta = 60°C
AC 3
@Ta = 40°C
Zero crossing detection
Min. operational current
Non-rep. surge current t = 10 ms
(Tj init. = 25°C)
Off-state leakage current @ rated voltage and frequency
(Tj. = 125°C, max.)
I2t for fusing t = 1 to 10 ms
Critical dV/dt off-state
Sense Specifications
Current
Sensed load current
Non-sensed leakage current
Voltage
Sensed line voltage
Non-sensed line voltage
Timing
Response time from fault
to alarm output
Short-circuit of semiconductor
2
Specifications are subject to change without notice (30.06.1999)
RN1S .......
Thermal Specifications
Insulation
Operating temperature
Storage temperature
Rated impulse withstand voltage
Input to output
4000 Vimp
Rated impulse withstand voltage
Output to case
4000 Vimp
- 20° to +70°C (-4° to +158°F)
- 40° to +100°C (-40° to +212°F)
Housing Specifications
Environment Specifications
Mounting
Weight with RHN1
Weight with RHN2
Housing material
Humidity max.
LED window material
Base plate
Potting compound
Terminals
Control terminals nominal
Min. cable dimenssion
Mounting torque max.
Power terminals nominal
Min. cable dimension
Mounting torque max.
Heatsink compound used
DIN-rail 35 mm
470 g
780 g
Glass reinforced noryl
SE1GFN1
PC Lexan 141R
Aluminium, nickel plated
Polyurethane, Casco Nobel
Screw with captive wire
clamp
4 mm2 or 2 x 2.5 mm2
AWG 12 or 2 x AWG 14
0.5 mm2, AWG 20
0.6 Nm
10 mm2 or 2 x 6 mm2
AWG 6 or 2 x AWG 10
1 mm2, AWG 16
2.0 Nm
Dow Corning 340
95%, no condensation
Dimensions
Dimensions with RHN 1 (30 A)
(H x W x D)
Dimensions with RHN 2 (50 A)
(H x W x D)
120 x 45 x 110 mm
120 x 90 x 110 mm
Operation Diagram
Normal
Relay
OFF
Operation
Relay
ON
Line
Voltage
Loss
Load
Open
Circuit
DC
Supply
Loss
Relay
Remains
OFF
Shorted
Relay
Line Voltage
Line Current
Control
Green LED
DC Supply
Red LED
Alarm output (normally open type)
= Half LED light intensity
Specifications are subject to change without notice (30.06.1999)
3
RN1S .......
Terminal Layout
Functional Diagrams
RN1S .....N.
VCC
A1
L1
B1
A1
L1
Alarm output X1
C/V
A2
Com
C/V
Control input B1
T1
RN1S .....P.
VCC
A1
L1
Alarm output X1
C/V
A2
Com
T1
A2
C/V
Control input B1
X1
T1
Shown with RHN1
Dimensions
89
103
37
70
120
71,6
20
37
45
71,6
93
45
4
4
20
70
120
60
60
30
30
103
72
33,7
RHN 1
4
All dimensions in mm
RHN 2
All dimensions in mm
Specifications are subject to change without notice (30.06.1999)