ETC RP130240-4-0

Solid State Relays
PCB, 1-Phase ZS/IO
Type RP 130 ...-.-., RP 132 ...-.-.
• AC Solid State Relay for PCB mounting
• Zero or instant-on switching
• Rated operational current: 2 and 4 AAC
• Non-repetitive voltage: Up to 850 Vp
• Rated operational voltage range: Up to 400 VACrms
• Input range: 3 to 32 VDC
• Insulation: OPTO (input-output) 4000 VACrms
Product Description
Ordering Key
The zero switching relay for
PCB mounting is used for a
wide range of applications
with either resistive or inductive loads.
The zero switching relay switches on when the AC sine
curve just crosses the zero
value, and the relay switches
off when the current crosses
zero.
The instant-on switching
relay switches on immediately when the control voltage is
applied. The relay switches
off when the current crosses
the zero value.
Solid State Relay (PCB)
Switching mode
Rated operational voltage
Rated operational current
Control voltage
Switching mode
Rated operational voltage
Rated operational current
Control voltage
130: Zero switching
132: Instant-on switching
240: 230 VACrms
440: 400 VACrms
2: 2 AACrms
4: 4 AACrms
0: 3 to 32 VDC
Control voltage
Rated operational current
2 AACrms
4 AACrms
RP 130 240-4-0
Type Selection
Selection Guide
Rated operational voltage
230 VACrms
3 to 32 VDC
RP 130 240-2-0*
RP 132 240-2-0**
RP 130 240-4-0*
RP 132 240-4-0**
400 VACrms
3 to 32 VDC
RP 130 440-2-0*
RP 132 440-2-0**
RP 130 440-4-0*
RP 132 440-4-0**
* Zero switching
** Instant-on switching
General Specifications
Operational voltage range
Non-rep. peak voltage
Zero voltage turn-on
Operational frequency range
Power factor
Approvals
CE-marking
RP 13. 240-.-0
RP 13. 440-.-0
24 to 280 VACrms
≥ 650 Vp
≤ 20 V
45 to 65 Hz
≥ 0.5 @ 230 VACrms
UL, CSA, VDE
Yes
48 to 480 VACrms
≥ 850 Vp
≤ 40 V
45 to 65 Hz
≥ 0.5 @ 400 VACrms
UL, CSA, VDE
Yes
Specifications are subject to change without notice (30.06.1999)
1
RP 130 ...-.-., RP 132 ...-.-.
Input Specifications
Control voltage range
Pick-up voltage
Drop-out voltage
Reverse voltage
Response time pick-up
Response time drop-out
Input impedance
RP 130 .40-.-0
RP 132 .40-.-0
3 to 32 VDC
≤ 3 VDC
≥ 1 VDC
≤ 6 VDC
≤ 1/2 cycle
≤ 1/2 cycle
1.5 kΩ
3 to 32 VDC
≤ 3 VDC
≥ 1 VDC
≤ 6 VDC
≤ 1 ms
≤ 1/2 cycle
1.5 kΩ
Output Specifications
Rated operational current AC 1
AC 3
Minimum operational current
Rep. overload current t=1 s
Non-rep. surge current t=20 ms
Off-state leakage current
@ rated voltage and frequency
I2t for fusing t=1-10 ms
Critical dl/dt
On-state voltage drop
@ rated current
Critical dV/dt commutating
Critical dV/dt off-state
RP 13. .40-2-0
RP 13. .40-4-0
2 Arms
2 Arms
20 mArms
≤ 6 Ap
42 Ap
4 Arms
3 Arms
20 mArms
≤ 12 Ap
90 Ap
≤ 5 mArms
≤ 9 A2s
≥ 10 A/µs
≤ 5 mArms
≤ 40 A2s
≥ 10 A/µs
≤ 1.6 Vrms
≥ 4 V/µs
≥ 100 V/µs
≤ 1.6 Vrms
≥ 4 V/µs
≥ 100 V/µs
Thermal Specifications
Operating temperature
Storage temperature
Junction temperature
Rth junction to case
Rth junction to ambient
RP 13. .40-2-0
RP 13. .40-4-0
-20° to +70°C (-4° to +158°F)
-40° to +100°C (-40° to +212°F)
≤ 125°C (≤ 257°F)
≤ 20.5 K/W
≤ 37.5 K/W
-20° to +70°C (-4° to +158°F)
-40° to +100°C (-40° to +212°F)
≤ 125°C (≤ 257°F)
≤ 15.6 K/W
≤ 22.5 K/W
Insulation Input-Output
Rated insulation voltage
Insulation resistance
Insulation capacitance
Reference voltage
according to VDE 01 10 B
Insulation group C
≥ 4000 VACrms
≥ 1010 Ω
≤ 8 pF
2
Weight
Housing material
Terminals
Potting compound
Approx. 10 g
Noryl GFN 1, black
Copper, tin-plated
Flame retardant polyurethane
500 VACrms, 600 VDC
Applications
These relays can be used to
switch heaters, motors, lights,
valves or solenoids.
When used at full load current, the relays must be placed
Housing Specifications
Accessories
vertically. If more than one
relay is mounted, please allow a minimum distance of 20
mm in between for sufficient
air cooling.
Fuses and varistors:
For further information refer to “General Accessories”.
Specifications are subject to change without notice (30.06.1999)
RP 130 ...-.-., RP 132 ...-.-.
Derating Curve
Wiring Diagram
Rated operational current
Control
input
Line/load
Ambient temperature
Functional Diagrams
RP 132 .40-.-0
RP 130 .40-.-0
Mains input/load output
Control
input
Mains input/load output
Control
input
Load output/mains input
Load output/mains input
**
Dimensions
**
*
*
* = ± 0.2 mm
** = ± 0.5 mm
Specifications are subject to change without notice (30.06.1999)