Solid State Relays PCB, 1-Phase ZS/IO Type RP 130 ...-.-., RP 132 ...-.-. • AC Solid State Relay for PCB mounting • Zero or instant-on switching • Rated operational current: 2 and 4 AAC • Non-repetitive voltage: Up to 850 Vp • Rated operational voltage range: Up to 400 VACrms • Input range: 3 to 32 VDC • Insulation: OPTO (input-output) 4000 VACrms Product Description Ordering Key The zero switching relay for PCB mounting is used for a wide range of applications with either resistive or inductive loads. The zero switching relay switches on when the AC sine curve just crosses the zero value, and the relay switches off when the current crosses zero. The instant-on switching relay switches on immediately when the control voltage is applied. The relay switches off when the current crosses the zero value. Solid State Relay (PCB) Switching mode Rated operational voltage Rated operational current Control voltage Switching mode Rated operational voltage Rated operational current Control voltage 130: Zero switching 132: Instant-on switching 240: 230 VACrms 440: 400 VACrms 2: 2 AACrms 4: 4 AACrms 0: 3 to 32 VDC Control voltage Rated operational current 2 AACrms 4 AACrms RP 130 240-4-0 Type Selection Selection Guide Rated operational voltage 230 VACrms 3 to 32 VDC RP 130 240-2-0* RP 132 240-2-0** RP 130 240-4-0* RP 132 240-4-0** 400 VACrms 3 to 32 VDC RP 130 440-2-0* RP 132 440-2-0** RP 130 440-4-0* RP 132 440-4-0** * Zero switching ** Instant-on switching General Specifications Operational voltage range Non-rep. peak voltage Zero voltage turn-on Operational frequency range Power factor Approvals CE-marking RP 13. 240-.-0 RP 13. 440-.-0 24 to 280 VACrms ≥ 650 Vp ≤ 20 V 45 to 65 Hz ≥ 0.5 @ 230 VACrms UL, CSA, VDE Yes 48 to 480 VACrms ≥ 850 Vp ≤ 40 V 45 to 65 Hz ≥ 0.5 @ 400 VACrms UL, CSA, VDE Yes Specifications are subject to change without notice (30.06.1999) 1 RP 130 ...-.-., RP 132 ...-.-. Input Specifications Control voltage range Pick-up voltage Drop-out voltage Reverse voltage Response time pick-up Response time drop-out Input impedance RP 130 .40-.-0 RP 132 .40-.-0 3 to 32 VDC ≤ 3 VDC ≥ 1 VDC ≤ 6 VDC ≤ 1/2 cycle ≤ 1/2 cycle 1.5 kΩ 3 to 32 VDC ≤ 3 VDC ≥ 1 VDC ≤ 6 VDC ≤ 1 ms ≤ 1/2 cycle 1.5 kΩ Output Specifications Rated operational current AC 1 AC 3 Minimum operational current Rep. overload current t=1 s Non-rep. surge current t=20 ms Off-state leakage current @ rated voltage and frequency I2t for fusing t=1-10 ms Critical dl/dt On-state voltage drop @ rated current Critical dV/dt commutating Critical dV/dt off-state RP 13. .40-2-0 RP 13. .40-4-0 2 Arms 2 Arms 20 mArms ≤ 6 Ap 42 Ap 4 Arms 3 Arms 20 mArms ≤ 12 Ap 90 Ap ≤ 5 mArms ≤ 9 A2s ≥ 10 A/µs ≤ 5 mArms ≤ 40 A2s ≥ 10 A/µs ≤ 1.6 Vrms ≥ 4 V/µs ≥ 100 V/µs ≤ 1.6 Vrms ≥ 4 V/µs ≥ 100 V/µs Thermal Specifications Operating temperature Storage temperature Junction temperature Rth junction to case Rth junction to ambient RP 13. .40-2-0 RP 13. .40-4-0 -20° to +70°C (-4° to +158°F) -40° to +100°C (-40° to +212°F) ≤ 125°C (≤ 257°F) ≤ 20.5 K/W ≤ 37.5 K/W -20° to +70°C (-4° to +158°F) -40° to +100°C (-40° to +212°F) ≤ 125°C (≤ 257°F) ≤ 15.6 K/W ≤ 22.5 K/W Insulation Input-Output Rated insulation voltage Insulation resistance Insulation capacitance Reference voltage according to VDE 01 10 B Insulation group C ≥ 4000 VACrms ≥ 1010 Ω ≤ 8 pF 2 Weight Housing material Terminals Potting compound Approx. 10 g Noryl GFN 1, black Copper, tin-plated Flame retardant polyurethane 500 VACrms, 600 VDC Applications These relays can be used to switch heaters, motors, lights, valves or solenoids. When used at full load current, the relays must be placed Housing Specifications Accessories vertically. If more than one relay is mounted, please allow a minimum distance of 20 mm in between for sufficient air cooling. Fuses and varistors: For further information refer to “General Accessories”. Specifications are subject to change without notice (30.06.1999) RP 130 ...-.-., RP 132 ...-.-. Derating Curve Wiring Diagram Rated operational current Control input Line/load Ambient temperature Functional Diagrams RP 132 .40-.-0 RP 130 .40-.-0 Mains input/load output Control input Mains input/load output Control input Load output/mains input Load output/mains input ** Dimensions ** * * * = ± 0.2 mm ** = ± 0.5 mm Specifications are subject to change without notice (30.06.1999) 3