ETC RXM-750L

Product Data Sheet
RXM-750
SONET/SDH Fiber-Optic Receiver Module
For Applications from 45MB/s to 750Mb/s
Features
Operating range of 45Mb/s to 750Mb/s
PECL Data Outputs
Single +5 Volt Supply
CMOS Loss of Signal Flag
Operation at 1300nm and 1520nm-1610nm
0° to +70°C Operation
-28dBm minimum sensitivity
Wide Dynamic Range
Multi-Sourced 20 Pin DIL Footprint
The RXM-750 SONET/SDH Fiber-Optic Receiver Module
Applications
Telecom Receiver Applications: Medium and Long
Haul SONET/SDH from 45Mb/s to 750Mb/s
High Performance Datacom Receiver Applications:
From 45Mb/s to 750MB/s
Description
VI’s RXM-750 is an integrated fiber-optic receiver
module. It is powered by a single +5V power supply and
is housed in a 20 PiN DIL package. It is ideally suited
for SONET OC-1, 3, 12 and other 45Mb/s to 750Mb/s
fiber-optic transmission applications that demand
superior performance. It is available with multi-mode
fiber pigtail with either a ST or LC connector.
Vectron International 166 Glover Avenue Norwalk CT. 06856-5160
Tel: 1-88-VECTRON-1
www.vectron.com
RXM-750 SONET/SDH Receiver Module
Product Data Sheet
Functional Overview
This highly integrated module converts a 45Mb/s to 750
Mb/s fiber-optic NRZ signal to differential PECL data
outputs. A CMOS flag alerts the user to a loss of signal
condition when the optical input falls below an
acceptable level.
A single +5 Volt supply provides bias for the module’s
preamplifier, and Quantizer. The photodiode may be
biased to +5 Volts. All elements are integrated into
fiber-coupled 1.3” X 0.635” 20 pin DIL package. The
RXM-750 footprint and pinout are industry common for
ease of integration.
The optical signal is coupled through a 62.5 µm
multimode optical fiber to a hermetic module which
encases an InGaAs PiN-photodiode and preamplifier.
The PiN-photodiode converts the optical signal to an
electrical current. The signal is then converted to a
voltage and amplified by a low noise transimpedance
amplifier.
Further gain is provided by the quantizer, which also
provides a Flag output when the optical signal falls
below an acceptable level.
Figure 1. RXM-750 Functional Block Diagram
Vectron International 166 Glover Avenue Norwalk CT. 06856-5160
Tel: 1-88-VECTRON-1
www.vectron.com
2
RXM-750 SONET/SDH Receiver Module
Product Data Sheet
Pin 1 Indicator
10
Top View
11
20
Figure 2. Pin Diagram (Top View)
Table 1. Pin Function
Pin
Symbol
7
Data
PECL Data Output.
9
Data
PECL Complementary Data Output.
10
VD
Detector Anode Bias. Connect to +5V or a +5V biased series resistor, for
1
received optical power monitoring.
11
VCC
5 Volt Supply Voltage.
12
Flag
Input Signal Level Status. This CMOS output switches low when the received
optical power falls below the Flag Threshold
1,2,3,6,8,13,15,16
GND
Ground.
4,5,14,17,18,19,20
NC
Function
No User Connection.
1. By connecting pin 10 to a +5 Volt bias through a series resistor (e.g. 1 kΩ) received optical power can be monitored as a voltage drop across the resistor.
Absolute Maximum Ratings
Absolute maximum ratings are provided here as
worst case and short duration exposure conditions
only. Exposure to conditions more severe than the
Absolute Maximum Ratings may result in permanent
damage. Exposure to conditions at the Absolute
Maximum Ratings for extended periods may also
adversely affect device performance or reliability.
Functional operation of the device is not implied at
these conditions.
Table 2. Absolute Maximum Ratings
Parameter
Symbol
Minimum
Maximum
Units
Storage Temperature Range
TS
-40
85
°C
Supply Voltage
VCC
0
+6
V
pin Detector Bias
VD
+5
+15
V
250/10
°C/s
Lead Soldering Conditions
Vectron International 166 Glover Avenue Norwalk CT. 06856-5160
Tel: 1-88-VECTRON-1
www.vectron.com
3
RXM-750 SONET/SDH Receiver Module
Product Data Sheet
Performance Characteristics
Table 3. Electrical Performance
Parameter
Symbol
Minimum
Maximum
Units
fO
45
750
Mb/s
Operating Temperature
TO
0
+70
°C
Power Supply Voltage
VCC
4.5
5.0
5.5
V
pin Detector Bias Voltage (pin10)
VD
5
5
15
V
Power Supply Current
ICC
250
mA
Input Signal Rate
1
Data Output Levels
Typical
2
Low
High
Data Output Rise and Fall Times
Received Power Level Flag
3
VOL
VCC - 1.95
VCC - 1.63
V
VOH
VCC - 1.03
VCC - 0.88
V
TR, TF
275
575
ps
375
LOS
Decreasing Optical Power
35
dBm
Increasing Optical Power
33
dBm
2
dB
Flag Hysteresis
Hyst
1. Other center frequencies are available. Please contact Vectron International for further details.
2. Measured with a load of RL = 50Ω to VCC - 2 V. See figures 3 and 4. ECL levels are specified for dc measurement, an additional tolerance of 50 mV should be included for
dynamic measurements.
3. Measured at 20% to 80% levels.
Figure 3. PECL Interface
Vectron International 166 Glover Avenue Norwalk CT. 06856-5160
Tel: 1-88-VECTRON-1
www.vectron.com
4
RXM-750 SONET/SDH Receiver Module
Product Data Sheet
Figure 4. ECL (AC Coupled) Interface
Figure 5. Typical Performance @ 155.52MHz
Table 4. Optical Performance
Parameter
Symbol
Minimum Average Sensitivity
Maximum Optical Input
1
Sens.
1
λ
23
Typical
Maximum
Units
-28
PMAX
Input Wavelength
1. For a BER less than 1E-10. Measured using a 2
Minimum
1100
dBm
-5
dBm
1610
nm
- 1 pseudorandom word and a 50% average optical duty cycle and a 10 dB Extinction Ratio.
Vectron International 166 Glover Avenue Norwalk CT. 06856-5160
Tel: 1-88-VECTRON-1
www.vectron.com
5
RXM-750 SONET/SDH Receiver Module
Product Data Sheet
Qualification
optical technologies that are used in similar products,
and have extensive field reliability data.
All components and technologies used in the optical
receiver are backed by qualification data covering
mechanical and environmental tests along with
accelerated life tests. Typical test, test conditions and
sample size are listed below.
The RXM-750 has been designed to comply with the
requirements of Bellcore specifications GR-468CORE, Reliability Assurance for Optoelectronic
Devices and will be subject to a complete
qualification test plan to demonstrate full compliance.
All of the technologies used in the assembly of the
module represent standard microelectronic and
Table 5. Qualification Plan
Test
Test Method
Sample Size
Physical Dimensions
MIL-STD-883, Method 2016
11
Mechanical Shock
MIL-STD-883, Method2002, Test B
11
Vibration, variable frequency
MIL-STD-883, Method 2007, Test A
11
Lead Solderability
MIL-STD-883, Method 2003
22 leeds
Lead Integrity
MIL-STD-883, Method 2004
15 leeds
Temperature Cycling
-40°C/85°C, 300 cycles
11
High Temperature Aging
85°C under bias, 2000 hours
11
Damp Bake
85°C/85% RH/ 1000hrs
11
Low Temperature Storage
-40°C, 168 hours
11
ESD
MIL-STD-883,Method 3015
3
Destructive Bond Pull
MIL-STD-883,Method 2011
40
Table 6. Optical Fiber Characteristics
Parameter
Minimum
Typical
Maximum
Units
Fiber Length
1000
mm
Fiber Core
62.5
µm
Fiber Buffer
900
µm
Vectron International 166 Glover Avenue Norwalk CT. 06856-5160
Tel: 1-88-VECTRON-1
www.vectron.com
6
RXM-750 SONET/SDH Receiver Module
Product Data Sheet
Outline Diagram
Figure 6. Outline Diagram
Ordering Information
Standard modules are built with 62.5um MM fiber, with an outer jacket diameter of 900um. Alternative fiber type,
connector type and fiber lengths are available upon request. Contact factory for specific details.
Table 7. Part Numbers
1
Fiber-Optic Connector
Model Number
VI Code Number
ST
RXM-750B
330013284
LC
RXM-750L
330014887
1. Other connectors or fiber requirements are available to meet specific application requirements.
USA: Vectron International • 166 Glover Avenue, Norwalk, CT 06856 • Tel: 1-88-VECTRON-1 • Fax: 1-888-FAX-VECTRON
EUROPE: In Denmark, Finland, Ireland, Italy, Israel, Norway, Spain, UK: Tel: 44 (0) 1703 766 288 • Fax: 44 (0) 1703 766 822
In Austria,Belgium,France,Germany,Luxenburg,Netherlands,Sweden,Switzerland:Tel: 49(0)7263 6480 • Fax:49(0)7263 6196
ASIA: In China, Taiwan, Japan: Tel: 01 603 598 0070 • Fax: 01 603 598 0075
In Korea, Singapore, Australia, India: Tel: 01 203 853 4433 • Fax: 01 203 853 1423
Vectron International, Inc. reserves the right to make changes to the product(s) and/or information contained herein without notice. No liability is
assumed as a result of their use or application. No rights under any patent accompany the sale of any such product(s) or information.
Vectron International 166 Glover Avenue Norwalk CT. 06856-5160
Tel: 1-88-VECTRON-1
www.vectron.com
7