VMI LTI402UFT

200 V - 1,000 V Single Phase Bridge
20.0 A - 25.0 A Forward Current
70 ns - 3000 ns Recovery Time
LTI402T - LTI410T
LTI402FT - LTI410FT
LTI402UFT-LTI410UFT
ELECTRICAL CHARACTERISTICS AND MAXIMUM RATINGS
Part Number
Working
Reverse
Voltage
Average
Rectified
Current
@TC
(Io)
(Vrwm)
Reverse
Current
@ Vrwm
Forward
Voltage
(Ir)
(Vf)
1 Cycle
Surge
Current
tp=8.3ms
(Ifsm)
Repetitive
Surge
Current
(Ifrm)
Reverse
Recovery
Time
(1)
(Trr)
Thermal
Impd.
uJ-C
55°C
100°C
25°C
100°C
25°C
25°C
25°C
25°C
Volts
Amps
Amps
µA
µA
Volts
Amps
Amps
Amps
ns
°C / W
LTI402T
LTI406T
LTI410T
200
600
1000
25.0
25.0
25.0
18.0
18.0
18.0
2.0
2.0
2.0
50
50
50
1.3
1.3
1.3
6.0
6.0
6.0
80
80
80
20
20
20
3000
3000
3000
0.75
0.75
0.75
LTI402FT
LTI406FT
LTI410FT
200
600
1000
20.0
20.0
20.0
15.0
15.0
15.0
2.0
2.0
2.0
50
50
50
1.7
1.7
1.7
6.0
6.0
6.0
80
80
80
20
20
20
150
150
150
0.75
0.75
0.75
LTI402UFT
LTI406UFT
LTI410UFT
200
600
1000
20.0
20.0
20.0
15.0
15.0
15.0
2.0
2.0
2.0
50
50
50
1.7
1.7
1.7
6.0
6.0
6.0
80
80
80
20
20
20
70
70
70
0.75
0.75
0.75
(1)Trr Testing: If=0.5A, Ir=1.0A, Irr=0.25A *Op. Temp. & Stg. Temp. = -55°C to +150°C Isolation Voltage: 2000V
.310(7.87) (2 PL)
.260(6.60)
(2 PL)
+
.800
(20.32)
AC
.140
(3.56)
.116 DIA.
THRU (2 PL)
.900(22.86)
.140
(3.56)
.300(7.62)
.130(3.30)
AC
.300(7.62)
.150
(3.81)
_
.520(13.21)
MAX.
AC
1.20(30.48)
1.50(38.1)
_
+
AC
Nickel Pltd.
Copper Base
Plate
Dimensions: In. (mm) • All temperatures are ambient unless otherwise noted. • Data subject to change without notice.
VOLTAGE MULTIPLIERS INC.
8711 W. Roosevelt Ave.
Visalia, CA 93291
247
TEL
559-651-1402
FAX
559-651-0740
www.voltagemultipliers.com
10
LTI402T - LTI410T • LTI402FT - LTI410FT • LTI402UFT - LTI410UFT
MAXIMUM FORWARD CURRENT
VS. TEMPERATURE
30
REVERSE CURRENT
VS. TEMPERATURE AT Vrwm
1000
400T
Reverse Current (uA)
Maximum Current (I)
25
20
400FT
400UFT
15
10
100
10
5
1
0
25
50
75
100
125
Ambient Temperature
Temperature (°C)
(C)
25
150
248
50
75
100
Temperature (°C)
Temperature
(C)
125
150