CIRCUIT PROTECTORS IP / No. 389 Protector Protector,, 65V Specifications For Short Circuit Protection of Sensitive Electronic Components and Assemblies Packaging Time-Current Characteristic Materials Base/Cap: Brown Thermoplastic Polyamide PA 6.6, UL 94V0 Round Pins: Copper, tin plated Time Lag (T) Operating Criteria max. 8 Maximum fault current: IFault < 10A at 250VAC Climatic Category -40ºC to +85ºC (consider de-rating) -25ºC/+70ºC/21 days (EN 60068-1..3) Stock Conditions +10ºC to +60ºC relative humidity ≤ 75% yearly average, without dew, maximum value for 30 days-95% Vibration Resistance 24 cycles at 15 min. each (EN 60068-6) 10 - 60Hz at 0.75mm amplitude 60 - 2000Hz at 10g acceleration 1,5 0,5 min 18,8 Operating TTemperature emperature For worldwide applications Reduced PCB space requirements Highly defined cut-off times Irreversible physical separation Low internal resistance Flame resistant encapsulated casing max. 4 8,5 ∅ 0,6 Maximum continuous current: IC > Ioperating max x F T time lag Features Dimensions (mm) 000: Tape/Ammopack (1400 pcs.) Lead Pull Strength 10N (EN 60068-2-21) Solderability 260ºC, ≤ 3 sec. (Wave) 350ºC, ≤ 1 sec. (Hand) 1 +0,1 5,08 Soldering Heat Resistance 260ºC, 10 sec. (IEC 60068-2-20) Holes in PCB Marking , Type Unit Weight 0.60g (approx.) Limits for Pre-arcing TTime ime Rated Current 1.4 x IRat 60mA 1.66 x IRat 2.5 x IRat > 600 s < 45 s Permissible continuous operating current is ≤ 10 0% at ambient temperature of 23ºC (73.4ºF). 100% Continous Type Amp Voltage Fault Cold Resistance Current Code Rating Current 0.1 x IC IC max. typ. (mΩ) 60mA 0060 250 V AC 10A/250VAC/DC 50-60Hz cosϕ=1.0 Power Dissipation 1.0 x IC max. (mW) Melting Integral 10 x IC typ. (A2s) 100 0.033 6080 Note: 1.00 means the number one with two decimal places. 1,000 means the number one thousand. Order Information 032906 Qty. OrderNumber Series 389 Amp Code Packaging In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. Specifications are subject to change without notice www.littelfuse.com PROTECTORS 00 0,0 10 IP / No. 389 I-t Characteristics ,00 10 (Min-Max Limit) Test value 0 1,0 00 10 Time (sec.) 0 10 1 0. 1 1 0.0 01 0.0 1 1.5 2 3 4 I Fault / I Rated 5 6 7 8 9 10 15 Contact Littelfuse for individual I-t curves 032906 In our continuing strategy to deliver unparalleled circuit protection solutions, technical expertise and application leadership, we proudly introduce the WICKMANN Group and its products to the Littelfuse portfolio. www.littelfuse.com