TOTAL POWER INT'L UNIVERSAL INPUT HARMONIC CORRECTION AC-DC N+1 REDUNDANCY AND ACTIVE CURRENT SHARING ENCLOSURE BOX WITH FAN TRIPLE OUTPUT 350 WATTS INTERNAL SWITCHING POWER SUPPLIES TPVP348 SERIES FEATURES: ACCOMMODATE UNIVERSAL AC SOURCES NO MINIMUM LOAD REQUIREMENT MEET IEC1000-3-2 HARMONIC CORRECTION N+1 REDUNDANCY & OR-ING DIODES THIRD-WIRE CURRENT SHARING MEET UNIVERSAL SAFETY STANDARDS EMI MEET EN55022 CLASS B CE MARKING COMPLIANCE SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: Universal 90-264Vac with PFC. Input Connector: Molex Mini-Fit (F-M) 42404-06A1. Input Frequency: 47-63Hz. Inrush Current: Typ. 25A @230Vac(Active circuit). Input Current: Typ. 5.4A @115Vac, 1.7A@ 230Vac. Dielectric Withstand: Meet IEC950. EMI: Meet CISPR EN55022 Class B. Hold-up Time: Typ. 38mS @ 115Vac & 230Vac. Power Fail Signal: Indicated by LEDs. Power Factor Correction & Harmonic Correction: Meet IEC1000-3-2, PF typ. 0.97-0.98 @ full load. Remote Inhibit/Power Disable: Installed. Earth Leakage: Less than 0.85 mA. Overload Protection (OLP): Fully protected against output overload and short circuit. Consult the factory for OLP setting. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Connector: Molex Mini-Fit (F-M) 42404-24A1. Output Wattage: Typ. 350 Watts. Line Regulation: Typ. 0.1%. Load Regulation: Independent & fully regulated Magnetic Amplifier outputs. VO1/VO2/VO3 typ. ±1.0%. Noise & Ripple: Typ. 1% peak to peak. OVP: Available at VO1,VO2 & VO3 (Latch circuit). Redundancy: Available for N+1 redundancy & OR-ing diodes built-in at all rails. Current Sharing: Third-wire load sharing at VO1,2,3. Adjustability: Available at VO1,VO2 & VO3. Over Current Protection (OCP): Installed in output VO1,VO2 and VO3. Over Temp. Protection (OTP): By thermostat. GENERAL SPECIFICATION Efficiency: Typ. 75-78.0%. Switching Frequency: 60K Hz. Circuit Topology: PWM fixed-frequency forward circuit. Transient Response: Output voltage returns in less than 3ms following a 25% load change. Safety Standard: UL1950/EN60950 Class I. Power Density: 2.8Watts / Cubic Inch. Operating Temperature: 0 to +50°C. Storage Temperature: -20 to +85°C. Temperature Coefficient: 0.04%/°C. Cooling: Internal cooling fan installed. Construction: Enclosure box installed with internal cooling fan. Hot Swappable (Insertion): Installed. TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: [email protected] http://www.total-power.com -1- OUTPUT VOLTAGE/CURRENT RATINGS CHART TRIPLE OUTPUT MODEL NO. TPVP348-T050DI TPVP348-T033EI TPVP348-T050II TPVP348-T033II TPVP348-T050MI TPVP348-T240EI Symbol: "★" OVP built-in. +VO1 ▲@★≡⊙ Typ. Volt. 28.0A +5.0V 28.0A +3.3V 28.0A +5.0V 28.0A +3.3V 28.0A +5.0V 7.0A +24.0V "@" Adjustable. "≡" 3rd-wire current sharing. +VO2 ▲@★≡⊙ Typ. Volt. 20.0A +3.3V 22.0A +5.0V 10.0A +12.0V 12.0A +12.0V 5.0A +24.0V 14.0A +5.0V +VO3 ▲@★≡⊙ Typ. Volt. 10.0A +12.0V 10.0A +12.0V 6.0A +12.0V 8.0A +12.0V 6.0A +12.0V 8.0A +12.0V "▲" Installed with magnetic amplifier. MECHANICAL DIMENSIONS: MM [INCHES] "⊙" Installed with OR-ing diode. WEIGHT: 1,200.0g (42.3 Oz.) OUTPUT GOOD FAULT INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT AC INPUT TRIPLE OUTPUT ASSIGNMENT AC-L AC-N AC-G VO1 CONNECTOR P1-1 P1-5 P1-3 P2-1,2,13,14 & PIN# Mating connector: Molex Mini-Fit 42385-06A1. Molex Mini-Fit 42385-24A1. VO2 VO3 P2-7,8,20 P2-9,21 DC-COM P2-3,4,5,15 16,17,18,19 ASSORTED SIGNALS Fan Power VO1≡ VO2≡ VO3≡ Inhibit Fail Good P2-22 P2-10 P2-23 P2-11 P2-24 TOTAL POWER INT'L Tel: 877-646-0900 Fax: 978-453-7395 Email: [email protected] http://www.total-power.com -2- P2-12 Power Disable P2-6