HITRON HAC202P-490

H HiTRON
2008/10/15
UNIVERSAL AC INPUT HARMONIC CORRECTION AC-DC HALF SIZE
HOT-SWAP CompactPCI QUAD OUTPUT 200 WATTS ACTIVE CURRENT
SHARING SWITCHING POWER SUPPLIES HAC202P SERIES
FEATURES:
„
„
„
„
„
„
„
„
200W 3U X 4HP HALF SIZE
EUROCARD PACKAGE
MEET IEC 61000-3-2 HARMONIC
CORRECTION
INTERNAL OR-ING DIODES FOR
N+1 REDUNDANCY
HOT-SWAPPABLE
THIRD-WIRE CURRENT SHARING
EMI MEET EN 55022 / FCC CLASS A
CE MARKING COMPLIANCE
FULLY COMPLIANT WITH PICMG
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: Typ. 90-264Vac.
Power Factor Correction: Meet Harmonic Correction
IEC 61000-3-2.Power Factor typ. 0.98-0.99.
Input Connector: Positronic 47-pin PCIH47M400A1.
Input Frequency: 47-63Hz.
Inrush Current: 6.85Arms @ 230Vac 50Hz.
Input Current: 2.45A @115Vac/1.13A @230Vac.
Dielectric Withstand: Meet IEC 60950-1 regulation.
EMI: Meet EN 55022 / FCC Class A.
Hold-up Time: 16.8mS @115Vac/230Vac.
Leakage Current: 0.45mA for IEC60950-1 Touch current.
Remote ON/OFF: Available at [INH#] & [EN#] pins.
Power Fail Signal: Available at [FAL#] pin.
Status LED: <Green> means valid input voltage.
<Amber> means a critical fault.
Thermal Protection (OTP): Installed NTC and
thermostat for thermal sensor at [DEG#] pin.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 200W continuous.
Output Connector: Positronic 47-pin PCIH47M400A1.
Line Regulation: Typ. 0.1%.
Load Regulation: Typ. ±1%.
Total Regulation: Typ. ±1.5%.
Noise & Ripple: Typ. 1% peak to peak .
OVP: Built-in at all outputs.
Adjustability: Available at VO1,2&3.
Remote Sensing: Available at VO1,VO2 & VO3.
Hot-Swap: Available.
N+1 Redundancy: Installed with internal OR-ing diodes
at all outputs for N+1 redundancy operation.
Current Sharing: Third-wire current sharing at VO1,2 &3.
Power OK Signal: Available for all output.
Over Current Protection (OCP): Installed at each rail.
Overload Protection (OLP): Fully protected against output
overload or short circuit. Typical 115-135% max. load.
Consult the factory for special OLP setting.
GENERAL SPECIFICATION
Efficiency: Typ. 75.5-80 %.
Switching Frequency: 125K Hz.
Circuit Topology: Forward circuit.
Transient Response: Peak transient less than 105mV and
recovers within 0.084mS after 25% load-change.
Safety Standard: IEC 60950-1 Class I.
Construction: Eurocard 3U X 4HP X 160mm
CompactPCI format.
Operating Temperature: 0 to +50 °C at full load with
specified air flow. Derates linearly to 50% at +70 °C.
Storage Temperature: -40 to +85 °C.
Temperature Coefficient: Typ. ±0.02% / °C.
Cooling: At least 30CFM(800 LFM) moving air is required
to achieve full rating power 200W in a confined area.
Power Density: 7.4 Watts/ Cubic Inch.
Note: Due to requests in market and advances in technology, specifications subject to change without notification.
1
OUTPUT VOLTAGE / CURRENT RATINGS CHART
2008/10/15
QUAD OUTPUT
MAIN +VO1 @★#≡☉
AUX. +VO2 ▲@★#≡☉※
AUX. +VO3 ▲≡#☉★@
AUX. –VO4 ☉★▲
MODEL NO.
HAC202P-490
Min.
Typ.
Volt.
Max.
Min.
2A
25A
+5V
27A
0A
Typ
Volt.
Max Min. Typ Volt. Max. Pk. Min. Typ. Volt. Max. Pk.
10A +3.3V 20A
0A
3A +12V 5A
6A
0A 0.5A -12V 1A
1A
Symbol: "★" OVP built-in. "@" Adjustable. "#" Remote sensing. "≡" 3rd-wire Load Sharing.
"☉" Installed with Or-ing diode. "▲" Magnetic Amplifier. "※" Synchronous Rectifier.
Remark: Peak load less than 60sec. with duty cycle <10%.
Max. load is the continuous operating load of each rail. But the max. load of each rail can't be drawn from all outputs at the same time.
Total max. power of V1 and V2 should be less than 175Watt.
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 700.0 g (24..7 Oz.)
INPUT & OUTPUT CONNECTORS PIN ASSIGNMENT
AC
INPUT
ASSIGNMENT
CNTR &PIN #
L
47
QUAD OUTPUT
N
G
VO1
46
1,2,
45
3,4
5V
S+
30
5V 5V
C.S.
S- Adj.
VO2
34
13,14,
15,16,
17,18
29
35
STATUS/CONTROL
3.3V 3.3V 3.3V
+12V
C.S. VO3
S+
S- Adj.
S+
33
34
Mating connector: PCIH47F400A1.
2
32
41
20
36
C.S VO4 DC COM EN# DEG# INH# FAL#
44
5,6,7,8,9,1
0,
21
11,12,19,2
4
27
38
39
42