ETC TLL-5902

MODEL TLL-5902
International size reference: 1/2AA, ER14252
TECHNICAL DATA
(Typical values @+25 ºC for batteries stored for one year or less)
Nominal capacity @ 1 mA, to 2V
1.1 Ah
Rated voltage
3.6 V
Maximum recommended continuous current
50 mA
Maximum pulse current capability
100 mA
Weight
9.6 g (0.339 oz)
Volume
4 cc
Operating temperature range
-55 ºC to +85 ºC
Li metal content
approx. 0.35 g
U.L. Component Recognition, MH 12193
Volts
DISCHARGE CHARACTERISTICS @ +25ºC
4.0
3.5
3.0
2.5
2.0
220 Ω
~14 mA
(0.80 Ah)
1.5
470 Ω
~7 mA
(0.97 Ah)
3.6 kΩ
~1 mA
(1.10 Ah)
40 kΩ
220 kΩ
27 kΩ
~0.125 mA ~40 µA
~17 µA
(1.08 Ah) (1.02 Ah) (0.92 Ah)
TERMINATIONS & ORDERING NO.
1.0
1
Volts
10
100
1000
10000
VOLTAGE VS. TEMPERATURE
100000
Hours
SUFFIX- /S STANDARD
15-5902-21530
SUFFIX- /T SOLDER TABS
15-5902-31530
SUFFIX- /P AXIAL PINS
15-5902-41530
SUFFIX- /PT2 RADIAL PINS
15-5902-36530
SUFFIX- /TP POLARIZED TABS
15-5902-52530
SUFFIX- /PT POLARIZED TABS
15-5902-53530
CAPACITY VS. CURRENT
Ah
1.2
3.7
-30 °C
4 µA
3.5
1.0
17 µA
25 °C
3.3
0.8
0.8 mA
3.1
0.6
2.9
2 mA
55 °C
72 °C
0.4
2.7
7 mA
14 mA
2.5
-50
0.2
-30
-10
10
30
50
70
90
ºC
0.01
0.1
1
10
mA
iXtra - Long Term High Performance
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
Rev. C 11/05
Page 1 of 2
TLL-5902
CELL FEATURES
3.6 V Primary lithium-thionyl chloride (Li-SOCl2)
Fast voltage recovery after long term storage and/or usage
High energy density
High and stable operating voltage
Low self discharge rate
10 years shelf life
Bobbin construction
Hermetic glass-to-metal-sealing
Non-flammable electrolyte
Non-restricted for transportation
Volts
MAIN APPLICATIONS
Utility meters (elect., water & gas)
Automatic meter reading
RF systems
Sensors & monitoring systems
Tracking systems
Wireless security systems
Automotive electronics
Industrial electronics
Ultra Low Power (ULP) devices
Others
VOLTAGE RESPONSE AFTER STORAGE
3.5
After 1 year
After 2 years
3.4
After 5 years
3.3
After 10 years
3.2
STORAGE CONDITIONS
3.1
Cells should be stored in a clean
& dry (less than 30 % RH) area
Temp. should not exceed +30 ºC
3.0
Pulse applied: 10 mA for 1 sec
Storage: RT
Background current: None
2.9
2.8
2.7
0
200
400
600
800
1000
VOLTAGE RESPONSE
Volts
3.5
For updated information please visit
our website www.tadiranbat.com
1200
msec
VOLTAGE RESPONSE
Volts
3.5
After 4 years
After 1 year
3.4
3.3
3.4
After 5 years
After 7 years
After 10 years
After 2 years
3.3
Pulse applied: 10 mA for 100 msec
Temperature: RT
Background current: 5 µA
3.2
After 1 year
Pulse applied: 10 mA for 100 msec
Temperature: RT
Background current: 10 µA
3.2
3.1
3.1
0
20
40
60
80
100
120
msec
0
20
40
60
80
100
120
msec
iXtra - Long Term High Performance
Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as
warranties either expressed or implied, of future performance.
Rev. C 11/05