MODEL TL-5937 International size reference: DD, ER32L1245 TECHNICAL DATA (Typical values @+ 25ºC for batteries stored for one year or less) Nominal capacity @ 10 mA, to 2 V 35 Ah Rated voltage 3.6 V Maximum recommended continuous current 450 mA Maximum pulse current capability 1000 mA Weight 190 g (6.702 oz) Volume 105 cc Operating temperature range -55 ºC to +85 ºC Li metal content approx. 10 g U.L. Component Recognition, MH 12193 Volts DISCHARGE CHARACTERISTICS @ +25ºC 4.0 3.5 3.0 2.5 2.0 13.5 Ω ~230 mA (22.5 Ah) 1.5 33 Ω ~100 mA (28.7 Ah) 180 Ω ~20 mA (34.0 Ah) 330 Ω ~10 mA (35.0 Ah) 1 kΩ ~3.5 mA (32.5 Ah) 11 kΩ ~330 µA (28.0 Ah) TERMINATIONS & ORDERING NO. 1.0 1 10 100 1000 10000 VOLTAGE VS. TEMPERATURE Volts SUFFIX- /S STANDARD 15-5937-21500 SUFFIX- /T SOLDER TABS 15-5937-31500 100000 Hours CAPACITY VS. CURRENT Ah 3.7 34.0 3.5 30.0 -30 °C 26.0 25 °C 22.0 55 °C 0 °C 0.4 mA 3.3 4 mA 3.1 40 mA 2.9 2.7 2.5 18.0 100 mA 72 °C 14.0 200 mA 10.0 400 mA 2.3 6.0 -50 -30 -10 10 30 50 70 90 ºC 0.1 1 10 100 mA iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. Rev. A 11/05 Page 1 of 2 TL-5937 CELL FEATURES 3.6 V Primary lithium-thionyl chloride (Li-SOCl2) Fast voltage recovery after long term storage and/or usage High energy density High and stable operating voltage Low self discharge rate 10 years shelf life Bobbin construction Hermetic glass-to-metal-sealing Non-flammable electrolyte Restricted for transportation (Class 9) Volts MAIN APPLICATIONS Utility meters (elect., water & gas) Automatic meter reading RF systems Sensors & monitoring systems Tracking systems Wireless security systems Automotive electronics Industrial electronics Ultra Low Power (ULP) devices Others VOLTAGE RESPONSE AFTER STORAGE After 2 years 3.4 After 1 year After 5 years 3.2 After 8 years STORAGE CONDITIONS 3.0 After 10 years Cells should be stored in a clean & dry (less than 30 % RH) area Temp. should not exceed +30 ºC 2.8 Pulse applied: 120 mA for 1 sec Storage: RT Background current: None 2.6 2.4 0 200 400 600 800 1000 VOLTAGE RESPONSE Volts 3.6 After 1 year 3.4 After 2 years 3.2 VOLTAGE RESPONSE Volts 3.6 After 1 year 3.4 For updated information please visit our website www.tadiranbat.com 1200 msec After 2 years 3.2 After 5 years 3.0 After 5 years 3.0 2.8 2.8 After 8 years After 10 years 2.6 2.6 Pulse applied: 120 mA for 100 msec Temperature: RT Background current: 100 µA 2.4 After 8 years Pulse applied: 120 mA for 100 msec Temperature: RT Background current: 200 µA 2.4 2.2 2.2 0 20 40 60 80 100 120 msec 0 20 40 60 80 100 120 msec iXtra - Long Term High Performance Note: Any presentations in this data sheet concerning performance are for information purpose only and are not construed as warranties either expressed or implied, of future performance. Rev. A 11/05 Page 2 of 2