OMRON EE

EE-SPX613
An Ideal Photomicrosensor for
Detecting Liquid Levels in
Transparent Pipes
Incorporates a Sensitivity Selector,
Built-in Amplifier, and Operation Mode
Selector
Tie-wrap and rubber tube provided to
prevent slippage
Suitable for any 6- to 13-mm diameter
transparent or semi-transparent pipe
with a wall thickness of 1 mm
Built-in amplifier saves space and wiring
effort
Compact size is ideal for the
miniaturization of equipment
Uses a talc-free cable that is ideal for
equipment used for the manufacturing
of semiconductors
Ordering Information
Appearance
Detection method
Output configuration
Part number
Through-beam (with groove)
Dark-ON or light ON
(selectable)
EE-SPX613
EE-SPX613
EE-SPX613
Specifications
RATINGS/CHARACTERISTICS
Part Number
EE-SPX613
12 to 24 VDC ±10%, ripple (p-p): 5% max.
Power supply voltage
Current consumption
Average value
30 mA max.
Peak value
80 mA max.
Applicable pipe
Any 6- to 13-mm-diameter pipe with a wall thickness of 1 mm that is made of FEP or any
other material as transparent as FEP.
Sensing object
Liquids in pipes (High-viscosity liquids or liquids with floating materials may not be
detected.)
Control output
Voltage:
Load current:
5 to 24 VDC
100 mA max.
Residual voltage:
0.8 V max. with a load current of 100 mA and 0.4 V max. with a load
current of 40 mA
Indicator
Light indicator (red) (Lit with incident.)
Connection method
Pre-wired (cable length: 1 m)
Enclosure rating
IEC IP50
Ambient illumination
3,000 x max. with incandescent light or sunlight on the receiver
Light source
Infrared LED (with a wavelength of 940 nm)
Material
Polycarbonate
y
Case
Cover
Ambient temperature
Operating
Ambient humidityy
--10°C to 55°C (14°F to 131°F)
Storage
--25°C to 65°C (-13°F to 149°F) (with no icing or condensation)
Operating
5% to 85%
Storage
5% to 95% (with no icing or condensation)
Vibration resistance
Destruction: 10 to 500 Hz, 1.0-mm single amplitude or 150 m/s2 in X, Y, and Z directions
3 times and for 11 min each
Shock resistance
Destruction: 500 m/s2 in X, Y, and Z directions 3 times each
ATTACHMENTS
Supporting belt
2
Slip protection tube
2
Nomenclature
PHYSICAL ATTRIBUTES
Operation mode selector
Sensitivity selector
Light indicator (red)
Cable
EE-SPX613
EE-SPX613
Operation
OUTPUT CIRCUIT
Operating status of output transistor
Dark-ON
Light-ON
Output circuit
Light indicator
(Red)
Main
circuit
12 to 24 VDC
(Brown)
Load 1
(Relay)
(Black)
Load 2
0V
(Blue)
* The RL is required if voltage output is required (i.e., transistor circuitry is connected).
Timing chart
Light (with no liquid)
Dark (with liquid)
Lit
Light indicator (red)
Not lit
Output transistor
Output transistor
Load 1 (Relay)
Load 2
Light (with no liquid)
Dark (with liquid)
Lit
Light indicator (red)
Not lit
Start
Reset
Load 1 (Relay)
Start
Reset
Load 2
OPERATION
The EE-SPX613 detects the level of liquid by detecting the
difference in refractive index between the air and liquid.
1. If there is no liquid in the pipe, the emitted beam will reach
the receiver after it is refracted by the pipe.
Pipe
Receiver
2. If there is liquid in the pipe, the emitted beam will pass
through the liquid and not reach the receiver.
Pipe
With liquid
Emitter
If there are floating materials on the surface of the liquid, light
reflected from the floating material may reach the receiver. In
such cases, set the sensitivity selector to Low and check the
operation of the EE-SPX613 for pipes with and without liquid.
If transmission of the light is impaired by stains on the pipe or an
emitter that has deteriorated with age, you may need to set the
sensitivity to HIGH.
Without liquid
Emitter
If the diameter of the pipe is close to 6 mm, some of the emitted
light may reach the receiver because the angle of refraction is
small. This may result in false readings. In such cases, set the
sensitivity selector to Low and check that the EE-SPX613 reads
correctly for pipes with and without liquid.
Receiver
EE-SPX613
EE-SPX613
Dimensions
Unit: mm
EE-SPX613
Optical axis
14.4
16 (0.57)
8.5
(0.63)
(0.33)
Pedestal
26
(1.02)
13
(0.51)
Sensing slit (1.8 x 0.8)
Optical axis
1
(0.04) 1.6
17.2
(0.68)
12.4 9.2
(0.49) (0.36)
1.8
(0.07)
6.6 dia.
Sensitivity selector
3.1
8.1
(0.32)
Light indicator
4.9
(0.19)
4.5
(0.18)
3.5
(0.14)
Operation mode
selector
Round vinyl-insulated
cable of 3.5 dia. (0.08 dia
x 30), 3 cores
Standard length: 1 m
Cable
Precautions
! WARNING
•
Do not supply or impose on the EE-SPX613 any AC current
or voltage exceeding the upper limit of the rated voltage
range, or the EE-SPX613 may be damaged.
•
Do not short-circuit the load connected to the EE-SPX613, or
the EE-SPX613 may be damaged.
Brown
Brown
Load
Sensor
Sensor
Black
Blue
Blue
•
Incorrect polarity resulting from wrong wiring or connections
may result in injury to the user or damage to the equipment.
Brown
Load
Sensor
Black
Blue
Load
Black
EE-SPX613
EE-SPX613
! Caution
Power Supply
Mounting
Always use supporting belts and slip protection tubes, which are
provided with the EE-SPX613, when attaching the EE-SPX613 to
an appropriate pipe, as shown in the following illustration. Make
sure that the pipe is in the center of the sensor groove and not
lifted from the pedestal.
When tightening the supporting belts, make sure that the pipe will
not be deformed.
Pipe
Operating Environment
The EE-SPX613 is not watertight. Do not use the EE-SPX613
outdoors.
Do not use the EE-SPX613 in places where water, oil, or
chemicals may splash or be sprayed onto the unit.
The exterior coverings of the EE-SPX613 are made of
polycarbonate. Keep the coverings away from any alkaline,
aromatic hydrocarbon, or aliphatic chloride hydrocarbon solvent,
all of which will damage the coverings.
Supporting belts
Slip protection
tubes
Ground the FG and GND terminals if a standard switching
regulator is used to supply power to the EE-SPX613, or the
EE-SPX613 may malfunction .
Pedestal
Sensor
Others
•
•
•
The EE-SPX613 requires 10 ms to be in stable operation
after power is supplied.
If two power supplies are used for the EE-SPX613 and load
respectively, be sure to supply power to the EE-SPX613
before supplying power to the load.
If there is a high-tension line near the cable, wire the cable
through an independent metal conduit to protect the
EE-SPX613 from damage or malfunction.
Do not attach the EE-SPX613 to improper pipes, such as
non-transparent pipes, or the EE-SPX613 may not operate
properly.
•
•
•
Do not impose any excessive force on the cable.
Do not pull the cable with a force exceeding 30 N.
Use an extension cable with conductors having a total crosssectional area of 0.15 mm2 (i.e., AWG26) and a total cable
length of 5 m maximum.
Do not impose a force exceeding 5 N on the operation mode
selector or sensitivity selector.
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON
ELECTRONICS,
INC.tel:+31 23 5681390, fax:+31 23 5681397, http://www.eu.omron.com/ema
OMRON CANADA, INC.
Omron
Europe
B.V. EMA-ISD,
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. EO5DAX4
1/99
Specifications subject to change without notice.
Printed in U.S.A.