Series DX 3A to 220 Vdc DIN Rail Relay, AC/DC Control Part Number Description DX22R1E-02 1A, 220 Vdc DX6R3E-02 3A, 60 Vdc DX6R3U-02 3A, 60 Vdc Part Number Explanation DX 22 R 1 E -02 FEATURES/BENEFITS • New generation of solid-state relays for DINrail mounting • Control visualization by LED • AC/DC control • High immunity to surges NOTES 1) Line Voltage (nominal): 6 = 60 Vdc; 22 = 220 Vdc 2) Switch Type: R = Random turn-on 3) Control Range: E = 5-30 Vdc (3-30 Vdc for DX6R3E-02); U = 90-240 Vdc 4) Feature: 02 = With LED MECHANICAL SPECIFICATION + 2-60VDC 3A input VAC 3.01 input VAC 3.01 (±0.002) (±0.002) (76.4) (76.4) 2-60VDC 3A ±0.002 1.14 (29) ±0.002 2.09 (53) ±0.001 ±0.001 .48 (12.2) WEIGHT: 1.06 oz (30g) .68 (17.2) DX6R3U-02 DX22R1E-02 DX6R3E-02 DESCRIPTION The Series DX relays are designed for DIN-rail mounting. These solid-state relays include a control LED that provides visual control status. The tight zerocross window significantly reduces EMI. Its compact size and user friendly package make the Series DX relay an excellent choice for designers. APPLICATIONS • Interface applications • Vending machines • Light/lamp control • Contactor driver • Fan speed control • HVAC controls Figure 1 — DX relays, dimensions in inches (mm) TYPICAL APPLICATION + 1+ BLOCK DIAGRAM 2– 3 1+ (*) Load AC/DC 2– – 4 Figure 2 — DX relays © 2003 TELEDYNE RELAYS Figure 3 — DX relays (800) 284-7007 • www.teledynerelays.com DX 1 DX\032003\Q1 Series DX INPUT (CONTROL) SPECIFICATION OUTPUT (LOAD) SPECIFICATION (Continued) Min Max Unit 5 30 Vdc Control Range DX22R1E-02 Min Max Unit DX22R1E-02 0.3 mA Off-State Leakage Current (60Hz) DX6R3E-02 3 30 Vdc DX6R3E-02 0.3 mA DX6R3U-02 90 240 Vac/dc DX6R3E-02 1 mA Turn-On Time 0.2 ms Turn-Off Time 0.8 ms Input Current Range DX22R1E-02 1 30 mA DX6R3E-02 1 30 mA DX6R3U-02 2 5.7 mA Off-State dv/dt 200 V/µs Must Turn-Off Voltage DX22R1E-02 1 Vdc DX6R3E-02 1 Vdc DX6R3U-02 15 Vac/dc Switching Frequency 500 Hz THERMAL CURVES Input Resistance (Typical) 6 1000 Ohms DX6R3E-02 600 Ohms DX6R3U-02 41,000 Ohms OUTPUT (LOAD) SPECIFICATION Min Max Unit Operating Range DX22R1E-02 2 220 V DX6 2 60 V See input voltage range 5 Load Current (Arms) DX22R1E-02 Vco ntro 4 lm Vco in ntro 3 2 DX6 l ma x Vcontr ol min DX22R1E-02 Vcontro l m ax 1 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature (°C) Peak Voltage DX22R1E-02 220 V DX6 60 V Figure 4 — DX relays ENVIRONMENTAL SPECIFICATION Min Load Current Range DX22R1E-02 .003 1 Operating Temperature –40 80 °C –40 105 °C 2500 DX6R3E-02 .003 3 A DX6R3U-02 .005 3 A Input-Output Isolation Input-Output Capacity 1.6 Unit A Storage Temperature On-State Voltage Drop Max Vrms 8 pF V NOTES: Maximum Surge Current Rating (Non-Repetitive) DX 2 DX22R1E-02 3 Apeak DX6R3E-02 5 Apeak DX6R3E-02 10 Apeak 1. Electrical specifications at 25°C unless otherwise specified. 2. On inductive loads, a free-wheeling diode (or clamp) is recommended. 3. For additional/custom options, contact factory. SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS DX\032003\Q1