Series FS Output to 20A 280 Vac DC Control Part Number Description FS24R10-06 10A, 280 Vac FS24D10-06 10A, 280 Vac FS24D10 10A, 280 Vac FS24D20-06 20A, 280 Vac Part Number Explanation FS 24 R 10 -06 FEATURES/BENEFITS • Miniature size package • Designed for medium-power applications • Faston or PCB terminals available • Tight zero-cross window for low EMI • Excellent thermal performance • High immunity to surges NOTES 1) Line Voltage (nominal): 24 = 240 Vac 2) Switch Type: R = Random turn-on; D = Zero-cross turn-on; 3) Feature: -06 = Faston terminals MECHANICAL SPECIFICATION .19x.03 (4.8x0.8) .25x.03 (6.35x0.8) .46 (11.6) .39 (10) .34 (8.6) .32 (8) .25 (6.4) .98 (25) .59 (15) .08 (2) 1.4 (35.5) 1.18 (30) WEIGHT: 3.2 oz. (90g) DESCRIPTION The Series FS relays are designed for medium-power loads. The design incorporates a triac output. The Series FS relays utilize optical isolation to protect the control from load transients. The FS compact package is available with faston or PCB terminals. Its compact size makes it ideal for designs where space is limited. The Series FS relays have excellent thermal performance. .5 (12.7) 2 -4 APPLICATIONS • Heating control • Motor control • Uninterruptible power supplies • Light dimmers • Industrial and process control • On/Off controls of medium-power AC equipment • Electromechanical line relay replacement .83 (21) .16 (4) 1 +3 .83 (21) Figure 1a — FS relays except FS24D10 Ø 0.5 (1.32) .24 (6) .83 (21) .59 (15) APPROVALS All models are UL recognized. UL File Number E128555. .08 (2) 1.4 (35.5) WEIGHT: 3.2 oz. (90g) 1.18 (30) EQUIVALENT CIRCUIT .5 (12.7) 2 –4 .2 (5.06) .16 (4) 3+ R 1~ .3 (7.62) .83 (21) +3 1 .83 (21) 4– ZERO CROSS 2~ Figure 1b — FS24D10 Figure 2 — FS relays © 2003 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com FS 1 FS\032003\Q1 Series FS INPUT (CONTROL) SPECIFICATION CONTROL CHARACTERISTIC Min Max Units FS24R 3 30 Vdc FS24D 4 30 Vdc FS24R 2 30 mAdc FS24D 3 30 mAdc 1 Vdc Input Current Range Must Turn-Off Voltage Input Current (mA) Control Range 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 0 All relays 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Control Voltage (V) Figure 3 — FS relays Input Resistance (Typical) All relays 1000 Ohms OUTPUT (LOAD) SPECIFICATION (Continued) Min Reverse Voltage Protection All relays 30 V Max Units Zero Cross Window (Typical) FS24 R NA FS24 D 12 Vac 3 mA FS24R 0.1 ms FS24D 8.3 ms 8.3 ms 500 V/µs 50 A/µs 0.1 440 Hz 10A output current .005 72 A2S 20A output current .005 200 A2S OUTPUT (LOAD) SPECIFICATION Input Type Min Max Units Operating Range Off-State Leakage Current (60Hz) All relays All relays 12 280 Vrms Turn-On Time (60 Hz) Peak Voltage All relays 600 Vpeak Load Current Range (Resistive) Turn-Off Time (60 Hz) 10A output current .005 10 Arms 20A output current .005 20 Arms All relays Off-State dv/dt Inductive Load Current All relays 10A output current 2.5 Arms 20A output current 4 Arms Maximum di/dt (Non-Repetitive) All relays Maximum Surge Current Rating (Non-Repetitive) 10A output current 120 A 20A output current 200 A On-State Voltage Drop All relays I2t for Match Fusing (<8.3ms) All relays output current FS 2 Operating Frequency Range 1.3 V SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE © 2003 TELEDYNE RELAYS FS\032003\Q1 Series FS ENVIRONMENTAL SPECIFICATION SURGE CURRENT Min Max Units Operating Temperature –40 100 °C Storage Temperature –40 100 °C 150 Apeak 100 Input-Output Isolation 4000 Vrms Output-Case Isolation 2500 Vrms Non-Repetitive 50 Repetitive with initial Tj = 70°C 0 0.01 0.1 1 t (s) 10 Figure 4a — All 10A FS relays output current NOTES: 1. External snubber is recommended when switching inductive loads. 2. Electrical specifications at 25°C unless otherwise specified. 3. For 800Hz applications, contact factory. 4. For additional/custom options, contact factory. Overload Current (A) 200 180 160 140 120 100 80 60 40 20 0 1 10 100 1000 Number of Cycles Figure 4b — FS24D20-06 output current THERMAL CHARACTERISTICS 13 9 8 90°C Power Dissipation (W) 10 0°C/W 2°C/W /W 4 °C 11 7 6 5 NO HE AT SIN K 4 3 Max Case Temperature (°C) 12 2 1 0 0 1 2 3 4 5 6 7 8 9 10 0 10 20 30 Load Current (Arms) 40 50 60 70 80 90 100 110 120 125 Ambient Temperature (°C) Figure 5a — All 10A FS relays output current 35 W 70 80 25 4° C/ 20 90 W 100°C 15 10 NO H EAT S IN 5 Max Case Temperature (°C) Power Dissipation (W) 2° C/ /W 0°C W C/ 1° W C/ 2° 1. W C/ 5° 1. 30 K 0 0 5 10 15 Load Current (Arms) 20 0 10 20 30 40 50 60 70 80 90 100 110 120 125 Ambient Temperature (°C) Figure 5b — FS24D20-06 output current © 2003 TELEDYNE RELAYS (800) 284-7007 • www.teledynerelays.com FS 3 FS\032003\Q1