TOTAL-POWER HES12-050240-8

H HiTRON
04/22/2002
UNIVERSAL OR U.S. INPUT RANGE AC TO DC EXTERNAL
WALLMOUNT ADAPTERS SINGLE OUTPUT 12 WATTS
SWITCHING POWER SUPPLIES HES12 OR HES12B SERIES
FEATURES:
LOW COST WALLMOUNT ADAPTER
DIVERSE AC PLUGS AVAILABLE
MEET DIVERSE SAFETY STANDARDS
EMI MEET EN 55022 OR FCC CLASS B
CE MARKING COMPLIANCE
SPECIFICATION
INPUT SPECIFICATION
OUTPUT SPECIFICATION
Input Voltage: HES12 typ. 90-264Vac, rating 100-240Vac.
HES12B typ. 90-132Vac, rating 120Vac.
Input Connector:
HES12: WM1 (U.S.2-blade)/WM3 (Euro-stecker)/
DT8(IEC320-2P).
HES12B: WM1 (U.S.2-blade).
Input Frequency: 47-63Hz.
Inrush Current:
HES12: Typ. 28A @ 230Vac by adding thermister.
HES12B: Typ. 22.5A @ 115Vac.
Input Current: HES12 Typ. 0.15A @ 230Vac.
HES12B Typ. 0.24A @ 115Vac.
Dielectric Withstand: Meet IEC950.
EMI: Meet EN 55022 or FCC Class B.
Hold-up Time: Typ. 13.2mS@115Vac/42.0mS@230Vac.
Output Voltage: See Ratings Chart.
Output Current: See Ratings Chart.
Output Wattage: Typ. 12 Watts.
Output Connector: Optional.
Line Regulation: Typ. 0.1%.
Load Regulation: Typ. ±2-3%.
Noise & Ripple: Typ. 1.0% peak to peak.
OVP: Built-in. By Zener diode clamping.
Adjustability: Factory set.
Overload Protection (OLP): Fully protected against output
overload or short circuit.
Typ. 120-150% max. load.
Consult the factory for special OLP setting
GENERAL SPECIFICATION
Efficiency: Typ. 80.5%.
Switching Frequency: Typ. 56-76K Hz.@ full load.
Circuit Topology: Free-running flyback circuit.
Transient Response: Output voltage returns typ. 1mS
following a 25% load change.
Safety Standard: UL1950/EN60950.Class II.
Power Density: 2.3 Watts. / Cubic Inch.
Operating Temperature: 0 to +40°C.
Storage Temperature: -20 to +85°C.
Temperature Coefficient: Typ. 0.04% /°C.
Cooling: Free air convection.
Construction: Impact resistant thermo-plastic
enclosure case.
Wallmount or Desktop format.
Notes: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified.
(2) Load regulation is measured at 230Vac or 120Vac in percentage to indicate the change in output voltage as the load is varied from half load to full load (±%).
(3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m) cord AWG#18 wires.
MODEL NO. DESCRIPTION: HES12 or B - XXX YYY – S
04/22/2002
INPUT AC PLUG: HES12: [1]WM1, [3]WM3, [8]DT8
HES12B: WM1
OUTPUT CURRENT
OUTPUT VOLTAGE
SERIES NAME (Hitron External Switcher): About 12W.
OUTPUT VOLTAGE/CURRENT RATINGS CHART
SINGLE OUTPUT
MODEL NO.
HES12-033240-1,3,8
HES12B-033240
HES12-050240-1,3,8
HES12B-050240
HES12-060200-1,3,8
HES12B-060200
HES12-065180-1,3,8
HES12B-065180
HES12-075160-1,3,8
HES12B-075160
HES12-090130-1,3,8
HES12B-090130
HES12-120100-1,3,8
HES12B-120100
HES12-150080-1,3,8
HES12B-150080
HES12-240050-1,3,8
HES12B-240050
HES12-480025-1,3,8
HES12B-480025
AC INPUT
AC PLUG
O/P VOLTAGE
O/P CURRENT
FORMAT
90-264Vac
120Vac
90-264Vac
120Vac
90-264Vac
120Vac
90-264Vac
120Vac
90-264Vac
120Vac
90-264Vac
120Vac
90-264Vac
120Vac
90-264Vac
120Vac
90-264Vac
120Vac
90-264Vac
120Vac
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
WM1/WM3/DT8
WM1
3.3V
3.3V
5.0V
5.0V
6.0V
6.0V
6.5V
6.5V
7.5V
7.5V
9.0V
9.0V
12.0V
12.0V
15.0V
15.0V
24.0V
24.0V
48.0V
48.0V
2.40A
2.40A
2.40A
2.40A
2.00A
2.00A
1.80A
1.80A
1.60A
1.60A
1.30A
1.30A
1.00A
1.00A
0.80A
0.80A
0.50A
0.50A
0.25A
0.25A
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop t
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
Wallmount/Desktop
Wallmount
MECHANICAL DIMENSIONS: MM [INCHES]
WEIGHT: 113g (4.0 Oz.)