H HiTRON 2008/04/14 HARMONIC CORRECTION (PFC) AC/DC MEDICAL APPLICATION EXTERNAL DESKTOP ADAPTER UNIVERSAL INPUT SINGLE OUTPUT 100 WATTS GREEN POWER SWITCHING POWER SUPPLIES HEMP100G SERIES FEATURES: ACCOMMODATE UNIVERSAL AC INPUT DESKTOP IEC320-3PL/2P AC RECEPTACLE GREEN POWER DESIGN/MEET ENERGY STAR(CEC) LVEVL IV. MEET MEDICAL STANDARDS EN60601-1/UL60601-1 EMI MEET EN55011/FCC CLASS B SPECIFICATION INPUT SPECIFICATION OUTPUT SPECIFICATION Input Voltage: 90-264Vac typical. Output Voltage: See Ratings Chart. Output Current: See Ratings Chart. Output Wattage: 100 Watts. Output Connector: Optional. Line Regulation: 0.3 % typical. Load Regulation: ± 2 % typical. Tolerance: ±4%. Noise & Ripple: 1% typical peak to peak. OVP: Built-in. (Latch) Adjustability: Not available. Over Temp. Protection (OTP): Installed. Overload Protection (OLP): Fully protected against output overload and short circuit. OLP set at about 110-135% rating output wattage. Consult the factory for OLP setting. Power Factor Correction (PFC) installed. Input Connector: IEC320-3PL/2P AC receptacle. Input Frequency: 50/60Hz. Inrush Current: 7.2Arms @230Vac 50Hz. Input Current: 0.976A@115Vac/0.496A@230Vac Dielectric Withstand: Meet IEC60601-1. EMI: Meet EN55011/FCC Class B. Hold-up Time: 22mS @115Vac/ 43mS@230Vac typical. Green Power: 0.37W @ 132Vac/ 0.50W @264Vac. Earth Leakage: Less than 0.126mA. GENERAL SPECIFICATION Efficiency: 88-90% typical. Switching Frequency: 40-65 KHz. Circuit Topology: Fixed Flyback Circuit. Transient Response: Output voltage returns in less than 1mS following a 25% load change. Safety Standard: Meet Medical standards UL60601-1 / EN60601-1Class I or II. Harmonic Current Emission, EN61000-3-2 compliance. Operating Temperature: 0 to +25/35/40°C without derating. (various with output voltage) Storage Temperature: -20 to +85°C. Temperature Coefficient: 0.04%/°C typical. Cooling: Free air convection. Construction: Impact resistant plastic enclosure case. Power Density: 4.56-5.5 Watts/Cubic inch. Desktop Format. NOTE: (1) All measurements are at nominal input, full load, and +25°C unless otherwise specified. (2) Load regulation is measured at 115Vac or 230Vac in percentage to indicate the change in output voltage as the load varied from half load to full load (±%). (3) The exact obtainable load regulation depends upon the output cord selected and load current. Upper data are for 6 ft. (2 m)cord AWG#18 wires. (4) Due to requests in market and advances in technology, specifications subject to change without notice. OUTPUT VOLTAGE/CURRENT RATINGS CHART 2008/04/14 SINGLE OUTPUT MODEL NO. AC PLUG O/P VOLTAGE O/P CURRENT HEMP100G-S120650-7L DT7L 12Vdc 6.5A HEMP100G-S120650-8 DT8 12Vdc 6.5A HEMP100G-S150620-7L DT7L 15Vdc 6.2A HEMP100G-S150620-8 DT8 15Vdc 6.2A HEMP100G-S190530-7L DT7L 19Vdc 5.3A HEMP100G-S190530-8 DT8 19Vdc 5.3A HEMP100G-S240420-7L DT7L 24Vdc 4.2A HEMP100G-S240420-8 DT8 24Vdc 4.2A HEMP100G-S360270-7L DT7L 36Vdc 2.7A HEMP100G-S360270-8 DT8 36Vdc 2.7A HEMP100G-S480200-7L DT7L 48Vdc 2.0A HEMP100G-S480200-8 DT8 48Vdc 2.0A HEMP100G-S580170-7L DT7L 58Vdc 1.7A HEMP100G-S580170-8 DT8 58Vdc 1.7A MECHANICAL DIMENSIONS: MM [INCHES] WEIGHT: 400.0g (14.18 Oz.)