PD-96915 RADIATION HARDENED IRHMK57260SE POWER MOSFET 200V, N-CHANNEL SURFACE MOUNT (Low-Ohmic TO-254AA) 5 TECHNOLOGY Product Summary Part Number IRHMK57260SE Radiation Level RDS(on) 100K Rads (Si) 0.044Ω ID 45A Low-Ohmic TO-254AA Tabless International Rectifier’s R5 TM technology provides high performance power MOSFETs for space applications. These devices have been characterized for Single Event Effects (SEE) with useful performance up to an LET of 80 (MeV/(mg/cm2)). The combination of low RDS(on) and low gate charge reduces the power losses in switching applications such as DC to DC converters and motor control. These devices retain all of the well established advantages of MOSFETs such as voltage control, fast switching, ease of paralleling and temperature stability of electrical parameters. Features: n n n n n n n n n n Low RDS(on) Fast Switching Single Event Effect (SEE) Hardened Low Total Gate Charge Simple Drive Requirements Ease of Paralleling Hermetically Sealed Ceramic Eyelets Electrically Isolated Light Weight Absolute Maximum Ratings Pre-Irradiation Parameter ID @ VGS = 12V, TC = 25°C ID @ VGS = 12V, TC = 100°C IDM PD @ TC = 25°C VGS EAS IAR EAR dv/dt TJ T STG Units Continuous Drain Current Continuous Drain Current Pulsed Drain Current À Max. Power Dissipation Linear Derating Factor Gate-to-Source Voltage Single Pulse Avalanche Energy Á Avalanche Current À Repetitive Avalanche Energy À Peak Diode Recovery dv/dt  Operating Junction Storage Temperature Range 45 29 180 208 1.67 ±20 256 45 20.8 19.8 -55 to 150 Pckg. Mounting Surface Temp. Weight 300 (for 5s) 8.0 (Typical) A W W/°C V mJ A mJ V/ns o C g For footnotes refer to the last page www.irf.com 1 12/24/04 IRHMK57260SE Pre-Irradiation Electrical Characteristics @ Tj = 25°C (Unless Otherwise Specified) Min IGSS IGSS Qg Q gs Q gd td(on) tr td(off) tf LS + LD Gate-to-Source Leakage Forward Gate-to-Source Leakage Reverse Total Gate Charge Gate-to-Source Charge Gate-to-Drain (‘Miller’) Charge Turn-On Delay Time Rise Time Turn-Off Delay Time Fall Time Total Inductance Typ Max Units 200 — — V — 0.25 — V/°C — — 0.044 Ω 2.5 35 — — — — — — 4.5 — 10 25 V S( ) — — — — — — — — — — — — — — — — — — — 6.8 100 -100 165 45 75 35 125 80 50 — Test Conditions VGS = 0V, ID = 1.0mA Reference to 25°C, ID = 1.0mA VGS = 12V, ID = 29A à nC VDS = VGS, ID = 1.0mA VDS = 15V, IDS = 29A à VDS= 160V ,VGS=0V VDS = 160V, VGS = 0V, TJ = 125°C VGS = 20V VGS = -20V VGS =12V, ID = 45A VDS = 100V ns VDD = 100V, ID = 45A VGS =12V, RG = 2.35Ω Ω Parameter BVDSS Drain-to-Source Breakdown Voltage ∆BV DSS /∆T J Temperature Coefficient of Breakdown Voltage RDS(on) Static Drain-to-Source On-State Resistance VGS(th) Gate Threshold Voltage g fs Forward Transconductance IDSS Zero Gate Voltage Drain Current µA nA nH Measured from Drain lead (6mm /0.25in. from package) to Source lead (6mm /0.25in. from package) with Source wires internally bonded from Source Pin to Drain Pad Ciss Coss Crss Rg Input Capacitance Output Capacitance Reverse Transfer Capacitance Internal Gate Resistance — — — — 5295 900 37 1.47 — — — — pF VGS = 0V, VDS = 25V f = 1.0MHz Ω f = 0.89MHz, open drain Source-Drain Diode Ratings and Characteristics Parameter Min Typ Max Units IS ISM VSD t rr Q RR Continuous Source Current (Body Diode) Pulse Source Current (Body Diode) À Diode Forward Voltage Reverse Recovery Time Reverse Recovery Charge ton Forward Turn-On Time — — — — — — — — — — 45 180 1.2 450 6.9 Test Conditions A V ns µC Tj = 25°C, IS = 45A, VGS = 0V à Tj = 25°C, IF = 45A, di/dt ≤100A/µs VDD ≤ 25V à Intrinsic turn-on time is negligible. Turn-on speed is substantially controlled by LS + LD. Thermal Resistance Parameter R thJC RthCS RthJA Junction-to-Case Case-to-Sink Junction-to-Ambient Min Typ Max Units — — — — 0.60 0.21 — — 48 Test Conditions °C/W Typical socket mount Note: Corresponding Spice and Saber models are available on International Rectifier Web site. For footnotes refer to the last page 2 www.irf.com Radiation Characteristics Pre-Irradiation IRHMK57260SE International Rectifier Radiation Hardened MOSFETs are tested to verify their radiation hardness capability. The hardness assurance program at International Rectifier is comprised of two radiation environments. Every manufacturing lot is tested for total ionizing dose (per notes 5 and 6) using the TO-3 package. Both pre- and post-irradiation performance are tested and specified using the same drive circuitry and test conditions in order to provide a direct comparison. Table 1. Electrical Characteristics @ Tj = 25°C, Post Total Dose Irradiation ÄÅ Parameter BVDSS V GS(th) IGSS IGSS IDSS RDS(on) RDS(on) VSD 100K Rads (Si) Drain-to-Source Breakdown Voltage Gate Threshold Voltage Gate-to-Source Leakage Forward Gate-to-Source Leakage Reverse Zero Gate Voltage Drain Current Static Drain-to-Source On-State Resistance (TO-3) Static Drain-to-Source On-state Resistance (Low-Ohmic TO-254) Diode Forward Voltage Min Max 200 2.0 — — — — 4.5 100 -100 10 Units Test Conditions µA VGS = 0V, ID = 1.0mA VGS = VDS, ID = 1.0mA VGS = 20V VGS = -20V VDS=160V, VGS=0V V nA — 0.049 Ω VGS = 12V, ID = 35A — 0.044 Ω VGS = 12V, ID = 35A — 1.2 V VGS = 0V, ID = 45A International Rectifier radiation hardened MOSFETs have been characterized in heavy ion environment for Single Event Effects (SEE). Single Event Effects characterization is illustrated in Fig. a and Table 2. Table 2. Single Event Effect Safe Operating Area Ion Br I Au LET MeV/(mg/cm2)) 37 60 82 VDS (V) Range (µm) @VGS=0V @VGS=-5V @VGS=-10V @VGS=-15V @VGS=-20V 39 200 200 200 200 200 32 200 200 200 185 120 28 200 200 150 50 25 Energy (MeV) 305 340 350 250 VDS 200 Br I Au 150 100 50 0 0 -5 -10 -15 -20 VGS Fig a. Single Event Effect, Safe Operating Area For footnotes refer to the last page www.irf.com 3 IRHMK57260SE Pre-Irradiation 1000 1000 VGS 15V 12V 10V 9.0V 8.0V 7.0V 6.0V BOTTOM 5.0V VGS 15V 12V 10V 9.0V 8.0V 7.0V 6.0V BOTTOM 5.0V TOP 100 10 ID, Drain-to-Source Current (A) ID, Drain-to-Source Current (A) TOP 100 1 0.1 5.0V 60µs PULSE WIDTH, Tj = 25°C 0.01 10 5.0V 1 60µs PULSE WIDTH Tj = 150°C 0.1 0.01 0.1 1 10 100 0.01 VDS , Drain-to-Source Voltage (V) Fig 1. Typical Output Characteristics T J = 150°C T J = 25°C 10 1 VDS = 50V 15 60µs PULSE WIDTH 5 6 7 8 9 10 VGS, Gate-to-Source Voltage (V) Fig 3. Typical Transfer Characteristics 4 RDS(on) , Drain-to-Source On Resistance (Normalized) ID, Drain-to-Source Current (A) 3.0 0.1 1 10 100 Fig 2. Typical Output Characteristics 1000 100 0.1 VDS , Drain-to-Source Voltage (V) ID = 45A 2.5 2.0 1.5 1.0 0.5 0.0 -60 -40 -20 VGS = 12V 0 20 40 60 80 100 120 140 160 TJ , Junction Temperature( °C) Fig 4. Normalized On-Resistance Vs. Temperature www.irf.com Pre-Irradiation VGS = 0V, f = 1MHz Ciss = Cgs + Cgd , Cds SHORTED Crss = Cgd Coss = Cds + Cgd C, Capacitance (pF) 8000 Ciss 6000 Coss 4000 Crss 2000 0 1 10 20 VGS , Gate-to-Source Voltage (V) 10000 IRHMK57260SE 12 8 4 VDS , Drain-to-Source Voltage (V) FOR TEST CIRCUIT SEE FIGURE 13 0 40 80 120 160 200 QG , Total Gate Charge (nC) Fig 5. Typical Capacitance Vs. Drain-to-Source Voltage Fig 6. Typical Gate Charge Vs. Gate-to-Source Voltage 1000 ID, Drain-to-Source Current (A) 1000 ISD, Reverse Drain Current (A) VDS = 160V VDS = 100V VDS = 40V 16 0 100 ID = 45A OPERATION IN THIS AREA LIMITED BY R DS(on) 100 100 T J = 150°C T J = 25°C 10 100µs 10 1ms 1 VGS = 0V 0.1 1 0.2 0.4 0.6 0.8 1.0 1.2 VSD , Source-to-Drain Voltage (V) Fig 7. Typical Source-Drain Diode Forward Voltage www.irf.com 1.4 10ms Tc = 25°C Tj = 150°C Single Pulse 1.0 10 100 1000 VDS , Drain-toSource Voltage (V) Fig 8. Maximum Safe Operating Area 5 IRHMK57260SE Pre-Irradiation 50 VGS 40 I D , Drain Current (A) RD VDS D.U.T. RG 30 + -VDD VGS Pulse Width ≤ 1 µs Duty Factor ≤ 0.1 % 20 Fig 10a. Switching Time Test Circuit VDS 10 90% 0 25 50 75 100 125 150 TC , Case Temperature ( °C) 10% VGS Fig 9. Maximum Drain Current Vs. Case Temperature td(on) tr t d(off) tf Fig 10b. Switching Time Waveforms 1 Thermal Response ( Z thJC ) D = 0.50 0.20 0.1 0.10 0.05 0.02 0.01 0.01 P DM t1 SINGLE PULSE ( THERMAL RESPONSE ) t2 0.001 Notes: 1. Duty Factor D = t1/t2 2. Peak Tj = P dm x Zthjc + Tc 0.0001 1E-006 1E-005 0.0001 0.001 0.01 0.1 1 t1 , Rectangular Pulse Duration (sec) Fig 11. Maximum Effective Transient Thermal Impedance, Junction-to-Case 6 www.irf.com Pre-Irradiation IRHMK57260SE 15V D.U.T. RG VGS 20V DRIVER L VDS + - VDD IAS A 0.01Ω tp Fig 12a. Unclamped Inductive Test Circuit EAS , Single Pulse Avalanche Energy (mJ) 500 ID 20A 28.5A BOTTOM 45A TOP 400 300 200 100 0 25 50 V(BR)DSS 75 100 125 150 Starting T J , Junction Temperature (°C) tp Fig 12c. Maximum Avalanche Energy Vs. Drain Current I AS Current Regulator Same Type as D.U.T. Fig 12b. Unclamped Inductive Waveforms 50KΩ QG 12 V QGS .3µF D.U.T. QGD + V - DS VGS VG 3mA Charge Fig 13a. Basic Gate Charge Waveform www.irf.com 12V .2µF IG ID Current Sampling Resistors Fig 13b. Gate Charge Test Circuit 7 IRHMK57260SE Pre-Irradiation Footnotes: À Repetitive Rating; Pulse width limited by maximum junction temperature. Á VDD = 50V, starting TJ = 25°C, L= 0.25mH Peak IL = 45A, VGS =12V  ISD ≤ 45A, di/dt ≤ 375A/µs, VDD ≤ 200V, TJ ≤ 150°C à Pulse width ≤ 300 µs; Duty Cycle ≤ 2% Ä Total Dose Irradiation with VGS Bias. 12 volt VGS applied and VDS = 0 during irradiation per MIL-STD-750, method 1019, condition A. Å Total Dose Irradiation with VDS Bias. 160 volt VDS applied and VGS = 0 during irradiation per MlL-STD-750, method 1019, condition A. Case Outline and Dimensions — Low-Ohmic TO-254AA Tabless NOT ES : 1. 2. 3. 4. DIMENS IONING & T OLERANCING PER AS ME Y14.5M-1994. ALL DIMENS IONS ARE S HOWN IN MILLIMET ERS [INCHES ]. CONTROLLING DIMENS ION: INCH. T HIS OUT LINE IS A MODIFIED TO-254AA JEDEC OUT LINE. PIN ASSIGNMENTS 1 = DRAIN 2 = SOURCE 3 = GATE CAUTION BERYLLIA WARNING PER MIL-PRF-19500 Packages containing beryllia shall not be ground, sandblasted, machined, or have other operations performed on them which will produce beryllia or beryllium dust. Furthermore, beryllium oxide packages shall not be placed in acids that will produce fumes containing beryllium. IR WORLD HEADQUARTERS: 233 Kansas St., El Segundo, California 90245, USA Tel: (310) 252-7105 IR LEOMINSTER : 205 Crawford St., Leominster, Massachusetts 01453, USA Tel: (978) 534-5776 TAC Fax: (310) 252-7903 Visit us at www.irf.com for sales contact information. Data and specifications subject to change without notice. 12/2004 8 www.irf.com