Under development New product Photocoupler PC957L0NSZ High Speed and High CMR *OPIC Photocoupler (Unit: mm) Outline Dimensions Features 2.54 ± 0.25 (1) High instantaneous common mode rejection voltage (CMR:MIN. 15kV/µs) (2) High speed response (tPHL:MAX. 0.8µs , tPLH:MAX. 0.8µs) (3) Isolation voltage(Viso(rms) : 5.0kV) (4) 8-pin DIP package (5) Flow soldering : 280˚C for 6s or less (6) Recognized by UL (file No. E64380) Under preparation for VDE standard 8 7 6 5 6.5 ± 0.5 PC957L Anode mark 1.2 ± 0.3 1 2 3 4 0.85 ± 0.2 3.4 ± 0.5 0.5 ± 0.1 7.62 ± 0.3 0.5TYP. 3.5 ± 0.5 9.66 ± 0.5 0.26 ± 0.1 Internal connection Applications (1) Programmable controller (2) Inverter 8 7 6 5 1 2 3 4 1 2 3 NC Anode Cathode NC 5 6 7 8 GND Vo NC Vcc 4 * "OPIC" (Optical IC) is a trademark of the SHARP Corporation. An OPIC consists of a light-detecting element and signal-processing circuit integrated onto a single chip. Absolute Maximum Ratings ( Ta=25˚C ) Input Output *1 *2 Parameter Forward current Reverse voltage Power dissipation Supply voltage Output voltage Output current Power dissipation Isolation voltage Operating temperature Storage temperature Soldering temperature Symbol IF VR P VCC VO IO PO Viso(rms) Topr Tstg Tsol Rating 25 5 45 −0.5 to +30 −0.5 to +20 8 100 5.0 −55 to +100 −55 to +125 270 Unit mA V mW V V mA mW kV ˚C ˚C ˚C *1 40 to 60% RH, for 1 minute *2 For 10s at the portion of 0.2mm or more from the root of lead pins (Notice) •In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. •Specifications are subject to change without notice for improvement. (Internet) •Data for Sharp's optoelectronic/power devices is provided on internet. (Address http://sharp-world.com/ecg/) 1/2 2D-010305 Photocoupler PC957L0NSZ Electro-optical Characteristics Input Parameter Forward voltage Reverse current Terminal capacitance High level output current Output High level supply current Low level supply current Low level output voltage Current transfer ratio Isolation resistance Floating capacitance Transfer characteristics (Ta=25˚C) Symbol Conditions VF IF=16mA IR VR=5V VF =0, f=1MHz Ct IF =0, V CC =5.5V I OH(1) VO =5.5V I OH(2) IF =0, V CC =15V, V O =15V I OH(3) IF =0, V CC =15V, V O =15V *3 I CCH(1) IF=0, VCC =15V, VO =OPEN I CCH(2) IF=0, VCC =15V, VO =OPEN *3 IF =16mA, V CC =15V, I CCL VO=OPEN IF =16mA, V CC =4.5V, V OL IO=2.4mA CTR(1) IF=16mA, VCC=4.5V, VO=0.4V CTR(2) IF=16mA, VCC=4.5V, VO=0.4V *3 R ISO DC500V, 40 to 60%RH Cf V=0V, f=1MHz MIN. − − − TYP. 1.7 − 60 MAX. 1.95 10 250 Unit V µA pF − 3 500 nA − − − − 0.01 − 0.02 − 1.0 50 1.0 2.0 µA − 120 − µA − 0.1 0.4 V 19 15 5×10 10 − − − 1011 0.6 50 − 1.0 µA % Ω pF "High→Low" transfer time t PHL IF =16mA, VCC =5V − 0.2 0.8 "Low→High" transfer time t PLH RL =1.9kΩ − 0.6 0.8 Instantaneous common mode rejection voltage "Output: High level" CM H 15 30 − kV/ µs Instantaneous common mode rejection voltage "Output: Low level" CM L −15 −30 − kV/ µs IF =0mA, RL=1.9kΩ, VCM =1.0kV P-P, VCC =5V IF =16mA, RL=1.9kΩ, VCM =1.0kVP-P , VCC =5V µs *3 Ta=0 to 70˚C As of April 2001 2/2 2D-010305 NOTICE ● The circuit application examples in this publication are provided to explain representative applications of SHARP devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes no responsibility for any problems related to any intellectual property right of a third party resulting from the use of SHARP's devices. ● Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP reserves the right to make changes in the specifications, characteristics, data, materials, structure, and other contents described herein at any time without notice in order to improve design or reliability. Manufacturing locations are also subject to change without notice. ● Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used specified in the relevant specification sheet nor meet the following conditions: (i) The devices in this publication are designed for use in general electronic equipment designs such as: - - - Personal computers - -- Office automation equipment - -- Telecommunication equipment [terminal] - - - Test and measurement equipment - - - Industrial control - -- Audio visual equipment - -- Consumer electronics (ii) Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when SHARP devices are used for or in connection with equipment that requires higher reliability such as: - -- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.) - - - Traffic signals - - - Gas leakage sensor breakers - - - Alarm equipment - -- Various safety devices, etc. (iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of reliability and safety such as: - - - Space applications - -- Telecommunication equipment [trunk lines] - -- Nuclear power control equipment - -- Medical and other life support equipment (e.g., scuba). ● Contact a SHARP representative in advance when intending to use SHARP devices for any "specific" applications other than those recommended by SHARP or when it is unclear which category mentioned above controls the intended use. ● If the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export such SHARP devices. ● This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written permission is also required before any use of this publication may be made by a third party. ● Contact and consult with a SHARP representative if there are any questions about the contents of this publication.