SHARP GP1A038RCKL

GP1A038RBK/GP1A038RBKL/GP1A038RCK/GP1A038RCKL
GP1A038RBK/GP1A038RBKL/
GP1A038RCK/GP1A038RCKL
OPIC Photointerrupter with
Encoder Function
■ Features
■ Outline Dimensions
*1 The derating factors of absolute maximum ratings due to ambient temperature
are shown in Fig.2 to 3
*2 For 5s
6
2
7.5
10.1
3
1.4
4
5
6
5
15
10.1
7.5
0.9
4-R2.6
038
O
Y
11.9
B
2-R0.5
1.7
8.8
3
4
5
6
(8.4)
(3.5)
2.1MIN
6.15
6-0.4
6-0.45
(1.8)
(1.8)
(1.8)
(1.8)
2-φ1.6±0.1
Light path
1.5
(1.79)
(2-1.4)
3
4
2
1
5
6
(2.54)
2
Anode
Cathode
GND
VOB
VOA
VCC
3.9
0.8
1
3
VCC=2.7 to 5.5V
Anode
Cathode
GND
VOB
VOA
VCC
1
4
+
−
PD1
1.8
13
8.1 4-R1.4
5
10kΩ
PD3
5
1.8
GP1A038RBKL/GP1A038RCKL
6
PD2
4
2-φ2±0.1
6 1.4
3
2
−
+
(7.2)
1.8
6.4
1.8
1
10kΩ
6
1.8
■ Internal connection diagram
PD4
5.7
(2.85)
2-φ1
.1
0.8
3.9
1.6
4.6
(0.14):Light path
0.6
3.15
1
0.6
20.2
˚C
˚C
˚C
2.54
2
3
4.6
−10 to +70
−40 to +80
260
1.7
1.8
B
(Ta=25°C)
Unit
mA
V
V
mA
mW
Rating
50
4
7
8
150
3.4
3.2±0.6
0.8
8.8
038
Parameter
Symbol
*1
Forward current
IF
Input
VR
Reverse voltage
Supply voltage
VCC
IOL
Output Low level output current
*1
Power dissipation
PO
Operating temperature
Topr
Tstg
Storage temperature
*2
Tsol
Soldering temperature
15
20.2
6.2
1. Printers
■ Absolute Maximum Ratings
R1.4
11.85
0.8
■ Applications
(Unit : mm)
GP1A038RBK/GP1A038RCK
12.0MAX.
1. Linear encoder for reading linear scale
2. Since the multi-divided photodiode system is adopted, highprecision reading is possible even if the angle is deviated
between the scale and encoder.
3. High resolution:
Resolution 150LPI (GP1A038RBK/GP1A038RBKL)
Resolution 180LPI (GP1A038RCK/GP1A038RCKL)
(4.2)
∗ Unspecified tolerance : ±0.3mm
∗ ( ) : Reference dimensions
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://sharp-world.com/ecg/
GP1A038RBK/GP1A038RBKL/GP1A038RCK/GP1A038RCKL
■ Electro-optical Characteristics
Input
Output
Parameter
Forward voltage
Reverse current
Operating supply voltage
Low level output voltage
High level output voltage
Supply current
Symbol
MIN.
Conditions
VF
−
IF=11mA
IR
−
VR=1V
VCC
2.7
−
−
VOL VCC=2.7 to 5.5V, IF=11mA, IOL=8mA
VCC=2.7 to 5.5V, IF=11mA
VCC−0.3
VOH
−
VCC=2.7 to 5.5V, IF=11mA, A and B low level
ICC
DA
35
DB
V
CC=2.7 to 5.5V, IF=11mA,
θAB1 to 4
45
+0.7
f=10kHz, Z=0.3−0.2 mm
tr
−
tf
−
fmax VCC=2.7 to 5.5V, IF=11mA, Z=0.3+0.7
−0.2 mm
−
Duty ratio
Transfer
Phase difference
characteristics Response time
*1
Response frequency
(Ta=25˚C)
Unit
V
µA
V
V
V
TYP.
1.3
−
5.0
−
−
−
MAX.
1.5
100
5.5
0.4
−
5
50
65
%
90
1.0
1.0
−
135
2.0
2.0
20
˚
µs
mA
µs
kHz
*1 Refer to the measuring condition. The values of transfer characteristics do not include an error of linear scale. Z is the distance between scale face and holder on the detector side.
Fig.1 Output Waveforms
tAP
tAH
A Output
θAB1
tAH
DA= ___ ×100
tAP
θAB4
θAB2
B Output
θAB3
tBH
DB= ___ ×100
tBP
tBH
tBP
Scale moving direction is shown in the measuring condition (Refer to Fig.4).
90%
90%
A, B Output 10%
tr
10%
tf
Fig.3 Output Power Dissipation vs.
Ambient Temperature
Output power dissipation PO (mW)
Fig.2 Forward Current vs. Ambient
Temperature
Forward current IF (mA)
80
60
50
40
25
20
0
−10 0
2025
40
60 70 80
Ambient temperature Ta (°C)
100
150
100
60
50
0
−10 0
20 25
40
60 70 80
Ambient temperature Ta (°C)
100
GP1A038RBK/GP1A038RBKL/GP1A038RCK/GP1A038RCKL
Fig.4 Measuring Condition
0˚
*3
,
X
X
*2A
150LPI (in GP1A038RBK)
180LPI (in GP1A038RCK)
(Unit : mm)
*1Z
Linear scale
2 or more
2.2 or more 4.2 or less
*1 Distance between scale face and holder on the detector side
*2 Scale moving direction
,
*3 X-X is the line which is through the center of
holder positioning pin, and it is parallel to the scale slit.
NOTICE
●
The circuit application examples in this publication are provided to explain representative applications of SHARP
devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes
no responsibility for any problems related to any intellectual property right of a third party resulting from the use of
SHARP's devices.
●
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP
reserves the right to make changes in the specifications, characteristics, data, materials, structure, and other contents
described herein at any time without notice in order to improve design or reliability. Manufacturing locations are
also subject to change without notice.
●
Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage
caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used
specified in the relevant specification sheet nor meet the following conditions:
(i) The devices in this publication are designed for use in general electronic equipment designs such as:
- - - Personal computers
- -- Office automation equipment
- -- Telecommunication equipment [terminal]
- - - Test and measurement equipment
- - - Industrial control
- -- Audio visual equipment
- -- Consumer electronics
(ii) Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when
SHARP devices are used for or in connection with equipment that requires higher reliability such as:
- -- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.)
- - - Traffic signals
- - - Gas leakage sensor breakers
- - - Alarm equipment
- -- Various safety devices, etc.
(iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of
reliability and safety such as:
- - - Space applications
- -- Telecommunication equipment [trunk lines]
- -- Nuclear power control equipment
- -- Medical and other life support equipment (e.g., scuba).
●
Contact a SHARP representative in advance when intending to use SHARP devices for any "specific" applications
other than those recommended by SHARP or when it is unclear which category mentioned above controls the
intended use.
●
If the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign
Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export such SHARP devices.
●
This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright
laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written
permission is also required before any use of this publication may be made by a third party.
●
Contact and consult with a SHARP representative if there are any questions about the contents of this publication.