MAXIM DS1251

19-6079; Rev 11/11
DS1251/DS1251P
4096K NV SRAM with Phantom Clock
FEATURES











PIN CONFIGURATIONS
Real-Time Clock Keeps Track of Hundredths
Of Seconds, Minutes, Hours, Days, Date of
the Month, Months, and Years
512K x 8 NV SRAM Directly Replaces
Volatile Static RAM or EEPROM
Embedded Lithium Energy Cell Maintains
Calendar Operation and Retains RAM Data
Watch Function is Transparent to RAM
Operation
Automatic Leap Year Compensation Valid
Up to 2100
Over 10 Years of Data Retention in the
Absence of Power
Full 10% Operating Range
Lithium Energy Source is Electrically
Disconnected to Retain Freshness Until
Power is Applied for the First Time
DIP Module Only
– Standard 32-Pin JEDEC Pinout
– Upward Compatible with the DS1248
PowerCap Module Board Only
− Surface Mountable Package for Direct
Connection to PowerCap Containing
Battery and Crystal
− Replaceable Battery (PowerCap)
− Pin-for-Pin Compatible with Other
Densities of DS124xP Phantom Clocks
Underwriters Laboratories (UL) Recognized
(www.maxim-ic.com/qa/info/ul/)
TOP VIEW
1
2
DS1251
3
4
5
6
7
8
9
10
11
12
32
31
30
29
28
27
26
25
24
23
22
21
VCC
A15
A17
WE
A13
A8
A9
A11
OE
A10
CE
DQ0
13
20
DQ6
DQ1
DQ2
14
19
DQ5
15
18
DQ4
16
17
DQ3
A18/RST
A16
A14
A12
A7
A6
A5
A4
A3
A2
A1
A0
GND
DQ7
Encapsulated Package
740-Mil Flush
RST
A15
A16
N.C.
VCC
WE
OE
CE
DQ7
DQ6
DQ5
DQ4
DQ3
DQ2
DQ1
DQ0
GND
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
DS1251P
X1
GND VBAT
X2
34
33
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
PowerCap Module Board
(Uses DS9034PCX+ PowerCap)
1 of 20
A18
A17
A14
A13
A12
A11
A10
A9
A8
A7
A6
A5
A4
A3
A2
A1
A0
DS1251/DS1251P
ORDERING INFORMATION
PART
TEMP RANGE
DS1251W-120+
DS1251W-120IND+
DS1251WP-120+
DS1251WP-120IND+
DS1251Y-70+
DS1251YP-70+
DS1251YP-70IND+
0°C to +70°C
-40°C to +85°C
0°C to +70°C
-40°C to +85°C
0°C to +70°C
0°C to +70°C
-40°C to +85°C
VOLTAGE
RANGE (V)
3.3
3.3
3.3
3.3
5.0
5.0
5.0
PIN-PACKAGE
32 EDIP (0.740a)
32 EDIP (0.740a)
34 PowerCap*
34 PowerCap*
32 EDIP (0.740a)
34 PowerCap*
34 PowerCap*
+ Denotes a lead(Pb)-free/RoHS-compliant package.
*DS9034PCX+ or DS9034I-PCX+ (PowerCap) required. Must be ordered separately.
PIN DESCRIPTION
EDIP
1
1
2
3
4
5
6
7
8
9
10
11
12
23
25
26
27
28
30
31
13
14
15
17
18
19
20
21
PIN
PowerCap
1
34
3
32
30
25
24
23
22
21
20
19
18
28
29
27
26
31
33
2
16
15
14
13
12
11
10
9
NAME
FUNCTION
RST
A18
A16
A14
A12
A7
A6
A5
A4
A3
A2
A1
A0
A10
A11
A9
A8
A13
A17
A15
DQ0
DQ1
DQ2
DQ3
DQ4
DQ5
DQ6
DQ7
Active-Low Reset Input. This pin has an internal pullup resistor connected to VCC.
Address Inputs
Data In/Data Out
2 of 20
DS1251/DS1251P
PIN DESCRIPTION (continued)
PIN
EDIP PowerCap
22
8
24
7
29
6
32
5
—
4
16
17
NAME
CE
OE
WE
VCC
N.C.
GND
FUNCTION
Active-Low Chip-Enable Input
Active-Low Output-Enable Input
Active-Low Write-Enable Input
Power-Supply Input
No Connection
Ground
DESCRIPTION
The DS1251 4096K NV SRAM with Phantom Clock is a fully static nonvolatile RAM (organized as
512K words by 8 bits) with a built-in real-time clock. The DS1251Y has a self-contained lithium energy
source and control circuitry, which constantly monitors VCC for an out-of-tolerance condition. When such
a condition occurs, the lithium energy source is automatically switched on and write protection is
unconditionally enabled to prevent garbled data in both the memory and real-time clock.
The phantom clock provides timekeeping information including hundredths of seconds, seconds, minutes,
hours, days, dates, months, and years. The date at the end of the month is automatically adjusted for
months with fewer than 31 days, including correction for leap years. The phantom clock operates in either
24-hour or 12-hour format with an AM/PM indicator.
PACKAGES
The DS1251 is available in two packages: 32-pin DIP and 34-pin PowerCap module. The 32-pin DIP
style module integrates the crystal, lithium energy source, and silicon in one package. The 34-pin
PowerCap module board is designed with contacts for connection to a separate PowerCap (DS9034PCX)
that contains the crystal and battery. This design allows the PowerCap to be mounted on top of the
DS1251P after the completion of the surface mount process. Mounting the PowerCap after the surface
mount process prevents damage to the crystal and battery because of the high temperatures required for
solder reflow. The PowerCap is keyed to prevent reverse insertion. The PowerCap Module Board and
PowerCap are ordered separately and shipped in separate containers.
RAM READ MODE
The DS1251 executes a read cycle whenever WE (write enable) is inactive (high) and CE (chip enable) is
active (low). The unique address specified by the 19 address inputs (A0–A18) defines which of the 512K
bytes of data is to be accessed. Valid data will be available to the eight data-output drivers within tACC
(access time) after the last address input signal is stable, providing that CE and OE (output enable) access
times and states are also satisfied. If OE and CE access times are not satisfied, then data access must be
measured from the later occurring signal ( CE or OE ) and the limiting parameter is either tCO for CE or
tOE for OE , rather than address access.
RAM WRITE MODE
The DS1251 is in the write mode whenever the WE and CE signals are in the active (low) state after
address inputs are stable. The latter occurring falling edge of CE or WE will determine the start of the
write cycle. The write cycle is terminated by the earlier rising edge of CE or WE . All address inputs must
3 of 20
DS1251/DS1251P
be kept valid throughout the write cycle. WE must return to the high state for a minimum recovery time
(tWR ) before another cycle can be initiated. The OE control signal should be kept inactive (high) during
write cycles to avoid bus contention. However, if the output bus has been enabled ( CE and OE active)
then WE will disable the outputs in tODW from its falling edge.
DATA RETENTION MODE
The 5V device is fully accessible and data can be written or read only when VCC is greater than VPF.
However, when VCC is below the power-fail point, VPF (point at which write protection occurs), the
internal clock registers and SRAM are blocked from any access. When VCC falls below the battery switch
point, VSO (battery supply level), device power is switched from the VCC pin to the backup battery. RTC
operation and SRAM data are maintained from the battery until VCC is returned to nominal levels.
The 3.3V device is fully accessible and data can be written or read only when VCC is greater than VPF.
When VCC falls below the power-fail point, VPF , access to the device is inhibited. If VPF is less than VBAT,
the device power is switched from VCC to the backup supply (VBAT ) when VCC drops below VPF . If VPF is
greater than VBAT, the device power is switched from VCC to the backup supply (VBAT ) when VCC drops
below VBAT. RTC operation and SRAM data are maintained from the battery until VCC is returned to
nominal levels.
All control, data, and address signals must be powered down when VCC is powered down.
PHANTOM CLOCK OPERATION
Communication with the phantom clock is established by pattern recognition on a serial bit stream of
64 bits, which must be matched by executing 64 consecutive write cycles containing the proper data on
DQ0. All accesses that occur prior to recognition of the 64-bit pattern are directed to memory.
After recognition is established, the next 64 read or write cycles either extract or update data in the
phantom clock, and memory access is inhibited.
Data transfer to and from the timekeeping function is accomplished with a serial bit stream under control
of chip enable, output enable, and write enable. Initially, a read cycle to any memory location using the
CE and OE control of the phantom clock starts the pattern recognition sequence by moving a pointer to
the first bit of the 64-bit comparison register. Next, 64 consecutive write cycles are executed using the
CE and WE control of the SmartWatch. These 64 write cycles are used only to gain access to the
phantom clock. Therefore, any address to the memory in the socket is acceptable. However, the write
cycles generated to gain access to the phantom clock are also writing data to a location in the mated
RAM. The preferred way to manage this requirement is to set aside just one address location in RAM as a
phantom clock scratch pad. When the first write cycle is executed, it is compared to bit 0 of the 64-bit
comparison register. If a match is found, the pointer increments to the next location of the comparison
register and awaits the next write cycle. If a match is not found, the pointer does not advance and all
subsequent write cycles are ignored. If a read cycle occurs at any time during pattern recognition, the
present sequence is aborted and the comparison register pointer is reset. Pattern recognition continues for
a total of 64 write cycles as described above until all the bits in the comparison register have been
matched (Figure 1). With a correct match for 64 bits, the phantom clock is enabled and data transfer to or
4 of 20
DS1251/DS1251P
from the timekeeping registers can proceed. The next 64 cycles will cause the phantom clock to either
receive or transmit data on DQ0, depending on the level of the OE pin or the WE pin. Cycles to other
locations outside the memory block can be interleaved with CE cycles without interrupting the pattern
recognition sequence or data transfer sequence to the phantom clock.
PHANTOM CLOCK REGISTER INFORMATION
The phantom clock information is contained in eight registers of 8 bits, each of which is sequentially
accessed 1 bit at a time after the 64-bit pattern recognition sequence has been completed. When updating
the phantom clock registers, each register must be handled in groups of 8 bits. Writing and reading
individual bits within a register could produce erroneous results. These read/write registers are defined in
Figure 2.
Data contained in the phantom clock register is in binary-coded decimal format (BCD). Reading and
writing the registers is always accomplished by stepping through all eight registers, starting with bit 0 of
register 0 and ending with bit 7 of register 7.
PHANTOM CLOCK REGISTER DEFINITION Figure 1
NOTE: THE PATTERN RECOGNITION IN HEX IS C5, 3A, A3, 5C, C5, 3A, A3, 5C. THE ODDS OF THIS PATTERN BEING ACCIDENTALLY
DUPLICATED AND CAUSING INADVERTENT ENTRY TO THE PHANTOM CLOCK IS LESS THAN 1 IN 1019. THIS PATTERN IS SENT TO
THE PHANTOM CLOCK LSB TO MSB.
5 of 20
DS1251/DS1251P
PHANTOM CLOCK REGISTER DEFINITION Figure 2
AM/PM/12/24 MODE
Bit 7 of the hours register is defined as the 12-hour or 24-hour mode-select bit. When high, the 12-hour
mode is selected. In the 12-hour mode, bit 5 is the AM/PM bit with logic high being PM. In the 24-hour
mode, bit 5 is the 20-hour bit (20–23 hours).
OSCILLATOR AND RESET BITS
Bits 4 and 5 of the day register are used to control the RST and oscillator functions. Bit 4 controls the
RST (pin 1). When the RST bit is set to logic 1, the RST input pin is ignored. When the RST bit is set to
logic 0, a low input on the RST pin will cause the phantom clock to abort data transfer without changing
data in the watch registers. Bit 5 controls the oscillator. When set to logic 1, the oscillator is off. When set
to logic 0, the oscillator turns on and the watch becomes operational. These bits are shipped from the
factory set to a logic 1.
ZERO BITS
Registers 1, 2, 3, 4, 5, and 6 contain one or more bits, which will always read logic 0. When writing these
locations, either a logic 1 or 0 is acceptable.
6 of 20
DS1251/DS1251P
BATTERY LONGEVITY
The DS1251 has a lithium power source that is designed to provide energy for clock activity, and clock
and RAM data retention when the VCC supply is not present. The capability of this internal power supply
is sufficient to power the DS1251 continuously for the life of the equipment in which it is installed. For
specification purposes, the life expectancy is 10 years at +25°C with the internal clock oscillator running
in the absence of VCC power. Each DS1251 is shipped from Maxim with its lithium energy source
disconnected, guaranteeing full energy capacity. When VCC is first applied at a level greater than VPF, the
lithium energy source is enabled for battery-backup operation. Actual life expectancy of the DS1251 will
be much longer than 10 years since no lithium battery energy is consumed when VCC is present.
CLOCK ACCURACY (DIP MODULE)
The DS1251 is guaranteed to keep time accuracy to within ±1 minute per month at +25°C. The clock is
calibrated at the factory by Maxim using special calibration nonvolatile tuning elements. The DS1251
does not require additional calibration and temperature deviations will have a negligible effect in most
applications. For this reason, methods of field clock calibration are not available and not necessary.
CLOCK ACCURACY (POWERCAP MODULE)
The DS1251P and DS9034PCX are each individually tested for accuracy. Once mounted together, the
module is guaranteed to keep time accuracy to within ±1.53 minutes per month (35ppm) at +25°C.
7 of 20
DS1251/DS1251P
ABSOLUTE MAXIMUM RATINGS
Voltage Range on Any Pin Relative to Ground
(5V product) . . . . . . . . . . . . . . . . . . . -0.3V to +6.0V
(3.3V product) . . . . . . . . . . . . . . . . . -0.3V to +4.6V
Storage Temperature Range
EDIP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
PowerCap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . -55°C to +125°C
Lead Temperature (soldering, 10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +260°C
Note: EDIP is wave or hand-soldered only
Soldering Temperature (reflow, PowerCap) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .+260°C
This is a stress rating only and functional operation of the device at these or any other conditions beyond those indicated in
the operation sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended
periods of time can affect reliability.
OPERATING RANGE
RANGE
Commercial
Industrial
TEMP RANGE
(NONCONDENSING)
0°C to +70°C
-40°C to +85°C
VCC (V)
3.3 ±10% or 5 ±10%
3.3 ±10% or 5 ±10%
RECOMMENDED OPERATING CONDITIONS
(TA = Over the operating range.)
PARAMETER
Logic 1 Voltage All
Inputs
Logic 0 Voltage All
Inputs
VCC = 5V ±10%
VCC = 3.3V ±10%
VCC = 5V ±10%
VCC = 3.3V ±10%
SYMBOL
VIH
VIL
8 of 20
MIN
TYP
MAX
2.2
VCC + 0.3
2.0
VCC + 0.3
-0.3
+0.8
-0.3
+0.6
UNITS
NOTES
V
11
V
11
DS1251/DS1251P
DC ELECTRICAL CHARACTERISTICS
(TA = Over the operating range.) (5V)
PARAMETER
0B
Input Leakage Current
I/O Leakage Current
CE ≥ VIH ≤ VCC
Output Current at 2.4V
Output Current at 0.4V
SYMBOL
MIN
IIL
TYP
MAX
UNITS
NOTES
-1.0
+1.0
µA
12
IIO
-1.0
+1.0
µA
IOH
IOL
-1.0
2.0
mA
mA
Standby Current CE = 2.2V
ICCS1
5
10
mA
Standby Current
CE = VCC - 0.5V
ICCS2
3.0
5.0
mA
Operating Current tCYC = 70ns
ICC01
85
mA
Write Protection Voltage
VPF
4.50
V
11
Battery Switchover Voltage
VSO
V
11
MAX
UNITS
NOTES
12
4.25
4.37
VBAT
6B
DC ELECTRICAL CHARACTERISTICS
(TA = Over the operating range.) (3.3V)
PARAMETER
1B
Input Leakage Current
I/O Leakage Current
CE ≥ VIH ≤ VCC
Output Current at 2.4V
Output Current at 0.4V
Standby Current CE = 2.2V
Standby Current
CE = VCC - 0.5V
Operating Current tCYC = 70ns
Write Protection Voltage
Battery Switchover Voltage
SYMBOL
MIN
IIL
-1.0
+1.0
µA
IIO
-1.0
+1.0
µA
IOH
IOL
ICCS1
-1.0
2.0
5
7
mA
mA
mA
2.0
3.0
mA
50
2.97
mA
V
11
V
11
NOTES
ICCS2
ICC01
VPF
TYP
2.80
VBAT or
VPF
VSO
7B
CAPACITANCE
(TA = +25°C)
PARAMETER
2B
Input Capacitance
Input/Output Capacitance
SYMBOL
CIN
CI/O
9 of 20
MIN
TYP
MAX
UNITS
5
5
10
10
pF
pF
DS1251/DS1251P
MEMORY AC ELECTRICAL CHARACTERISTICS
(TA = Over the operating range.) (5V)
PARAMETER
3B
SYMBOL
DS1251Y-70
MIN
MAX
70
UNITS
NOTES
8B
9B
Read Cycle Time
tRC
Access Time
tACC
70
ns
OE to Output Valid
tOE
35
ns
CE to Output Valid
tCO
70
ns
OE or CE to Output Active
tCOE
Output High-Z from Deselection
tOD
Output Hold from Address Change
tOH
5
ns
Write Cycle Time
tWC
70
ns
Write Pulse Width
tWP
50
ns
Address Setup Time
tAW
0
ns
Write Recovery Time
tWR
0
ns
Output High-Z from WE
tODW
Output Active from WE
tOEW
Data Setup Time
Data Hold Time from WE
5
25
25
ns
ns
5
ns
5
3
ns
5
5
ns
5
tDS
30
ns
4
tDH
5
ns
4
10 of 20
DS1251/DS1251P
PHANTOM CLOCK AC ELECTRICAL CHARACTERISTICS
(TA = Over the operating range.) (5V)
PARAMETER
SYMBOL
MIN
Read Cycle Time
tRC
65
CE Access Time
tCO
55
ns
OE Access Time
tOE
55
ns
CE to Output Low-Z
tCOE
5
ns
OE to Output Low-Z
tOEE
5
ns
CE to Output High-Z
tOD
25
ns
5
OE to Output High-Z
tODO
25
ns
5
Read Recovery
tRR
10
ns
Write Cycle Time
tWC
65
ns
Write Pulse Width
tWP
55
ns
3
Write Recovery
tWR
10
ns
10
Data Setup Time
tDS
30
ns
4
Data Hold Time
tDH
0
ns
4
CE Pulse Width
tCW
60
ns
RST Pulse Width
tRST
65
ns
10B
TYP
MAX
UNITS
NOTES
ns
POWER-DOWN/POWER-UP TIMING
(TA = Over the operating range.) (3.3V)
PARAMETER
SYMBOL
MIN
CE at VIH before Power-Down
tPD
0
µs
VCC Slew from VPF(MAX) to
VPF(MIN)(CE at VPF)
tF
300
µs
VCC Slew from VPF(MIN) to VSO
tFB
10
µs
VCC Slew from VPF(MAX) to
VPF(MIN) (CE at VPF)
tR
0
µs
CE at VIH after Power-Up
tREC
1.5
SYMBOL
MIN
tDR
10
1B
TYP
MAX
UNITS
NOTES
2.5
ms
MAX
UNITS
NOTES
years
9
(TA = +25°C)
PARAMETER
4B
Expected Data Retention Time
TYP
Warning: Under no circumstances are negative undershoots of any amplitude allowed when device
is in battery-backup mode.
11 of 20
DS1251/DS1251P
MEMORY AC ELECTRICAL CHARACTERISTICS
(TA = Over the operating range.) (3.3V)
PARAMETER
SYMBOL
12B
DS1251W-120
MIN
MAX
120
120
60
120
5
40
5
120
90
0
20
40
5
50
20
UNITS
13B
14B
NOTES
15B
16B
Read Cycle Time
Access Time
OE to Output Valid
CE to Output Valid
OE or CE to Output Active
Output High-Z from Deselection
Output Hold from Address Change
Write Cycle Time
Write Pulse Width
Address Setup Time
Write Recovery Time
Output High-Z from WE
Output Active from WE
Data Setup Time
Data Hold Time from WE
tRC
tACC
tOE
tCO
tCOE
tOD
tOH
tWC
tWP
tAW
tWR
tODW
tOEW
tDS
tDH
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
5
5
3
10
5
5
4
4
PHANTOM CLOCK AC ELECTRICAL CHARACTERISTICS
(TA = Over the operating range.) (3.3V)
PARAMETER
SYMBOL
MIN
Read Cycle Time
tRC
120
CE Access Time
tCO
100
ns
OE Access Time
tOE
100
ns
CE to Output Low-Z
tCOE
5
ns
OE to Output Low-Z
tOEE
5
ns
CE to Output High-Z
tOD
40
ns
5
OE to Output High-Z
tODO
40
ns
5
Read Recovery
tRR
20
ns
Write Cycle Time
tWC
120
ns
Write Pulse Width
tWP
100
ns
3
Write Recovery
tWR
20
ns
10
Data Setup Time
tDS
45
ns
4
Data Hold Time
tDH
0
ns
4
CE Pulse Width
tCW
105
ns
RST Pulse Width
tRST
120
ns
12 of 20
TYP
MAX
UNITS
NOTES
ns
DS1251/DS1251P
POWER-DOWN/POWER-UP TIMING
(TA = Over the operating range.) (3.3V)
PARAMETER
SYMBOL
MIN
CE at VIH before Power-Down
tPD
0
µs
VCC Slew from VPF(MAX) to
VPF(MIN) (CE at VIH)
tF
300
µs
VCC Slew from VPF(MAX) to
VPF(MIN) (CE at VIH)
tR
0
µs
CE at VIH after Power-Up
tREC
1.5
SYMBOL
tDR
MIN
10
17B
TYP
MAX
UNITS
2.5
ms
MAX
UNITS
years
NOTES
(TA = +25°C)
PARAMETER
Expected Data Retention Time
5B
TYP
NOTES
9
Warning: Under no circumstances are negative undershoots of any amplitude allowed when device
is in battery-backup mode.
13 of 20
DS1251/DS1251P
MEMORY READ CYCLE (Note 1)
MEMORY WRITE CYCLE 1 (Notes 2, 6, and 7)
14 of 20
DS1251/DS1251P
MEMORY WRITE CYCLE 2 (Notes 2 and 8)
RESET FOR PHANTOM CLOCK
READ CYCLE TO PHANTOM CLOCK
15 of 20
DS1251/DS1251P
WRITE CYCLE TO PHANTOM CLOCK
POWER-DOWN/POWER-UP CONDITION (5V)
16 of 20
DS1251/DS1251P
POWER-DOWN/POWER-UP CONDITION (3.3V)
17 of 20
DS1251/DS1251P
AC TEST CONDITIONS
Output Load: 50pF + 1TTL Gate
Input Pulse Levels: 0 to 3V
Timing Measurement Reference Levels
Input: 1.5V
Output: 1.5V
Input Pulse Rise and Fall Times: 5ns
NOTES:
1) WE is high for a read cycle.
2) OE = VIH or VIL. If OE = VIH during write cycle, the output buffers remain in a high-impedance state.
3) tWP is specified as the logical AND of CE and WE. tWP is measured from the latter of CE or WE going
low to the earlier of CE or WE going high.
4) tDH, t DS are measured from the earlier of CE or WE going high.
5) These parameters are sampled with a 50pF load and are not 100% tested.
6) If the CE low transition occurs simultaneously with or later than the WE low transition in Write Cycle
1, the output buffers remain in a high-impedance state during this period.
7) If the CE high transition occurs prior to or simultaneously with the WE high transition, the output
buffers remain in a high-impedance state during this period.
8) If WE is low or the WE low transition occurs prior to or simultaneously with the CE low transition,
the output buffers remain in a high impedance state during this period.
9) The expected tDR is defined as cumulative time in the absence of VCC with the clock oscillator
running.
10) tWR is a function of the latter occurring edge of WE or CE.
11) Voltages are referenced to ground.
12) RST (Pin 1) has an internal pullup resistor.
13) Real-time clock modules can be successfully processed through conventional wave-soldering
techniques as long as temperature exposure to the lithium energy source contained within does not
exceed +85°C. Post-solder cleaning with water-washing techniques is acceptable, provided that
ultrasonic vibration is not used.
In addition, for the PowerCap:
1) Maxim recommends that PowerCap Module bases experience one pass through solder reflow oriented
with the label side up (“live-bug”).
2) Hand soldering and touch-up: Do not touch or apply the soldering iron to leads for more than three
seconds.
− To solder, apply flux to the pad, heat the lead frame pad, and apply solder. To remove the part,
apply flux, heat the lead frame pad until the solder reflows, and use a solder wick to remove
solder.
18 of 20
DS1251/DS1251P
PACKAGE INFORMATION
For the latest package outline information and land patterns (footprints), go to www.maxim-ic.com/packages.
Note that a “+”, “#”, or “-” in the package code indicates RoHS status only. Package drawings may show a
different suffix character, but the drawing pertains to the package regardless of RoHS status.
PACKAGE TYPE
32 EDIP
34 PWRCP
PACKAGE CODE
MDT32+5
PC2+5
19 of 20
OUTLINE NO.
21-0245
21-0246
LAND PATTERN NO.
—
—
DS1251/DS1251P
REVISION HISTORY
REVISION
DATE
11/11
DESCRIPTION
Updated the Features, Ordering Information, AM/PM/12/24-MODE, and
Absolute Maximum Ratings, and Package Information sections
PAGES
CHANGED
1, 2, 6, 8, 19
20 of 20
Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circuit patent licenses are implied. Maxim
reserves the right to change the circuitry and specifications without notice at any time.
M a x i m I n t e g r a t e d P r o d u c t s , 1 2 0 S a n G a b r i e l D r iv e , S u n n y v a le , C A 9 4 0 8 6 4 0 8- 7 3 7 - 7 6 0 0
© 2011 Maxim Integrated Products
Maxim is a registered trademark of Maxim Integrated Products, Inc.