SHARP S201N11

S101N11/S101N12/S201N11/S201N12
S101N11/S101N12
S201N11/S201N12
Voltage Input Type
Solid State Relay
with Built-in Snubber Circuit
■ Features
■ Outline Dimensions
1. Built-in snubber circuit
2. Input side voltage operation type
3. Built-in zero-cross circuit (S101N12/S201N12)
4. RMS ON-state current IT : MAX. 1.6Arms
26.0MAX.
21.0MAX.
(DIN Standard)
S101N11
INPUT
OUTPUT
5VDC
1.6A120VAC
−+
3.5±0.5
1. Programmable controllers
2. Copiers
3. Air conditioners
4. Automatic vending machines
∼
2.54
2.54
■ Model line-ups
0.5
10.16
4 3
For 100V lines
S101N11
S101N12
5.5MAX.
Lot No.
■ Applications
No zero-cross circuit
Built-in zero-cross circuit
1.3±0.3
7.62
2
For 200V lines
S201N11
S201N12
Internal connection diagram
Input
Output
S101N11
Output
S101N12
supply
voltage S201N11
S201N12
RMS ON-state current
Peak one cycle surge current
Operating temperature
Storage temperature
*3
Isolation voltage
*4
Soldering temperature
*2
Rating
3 to 6
6
V
V
S101N12/S201N12
Z.C.
Parameter
Symbol
Input signal voltage
VIN
Reverse voltage
VR
S101N11
Standard S101N12
−
voltage S201N11
S201N12
Operating frequency
f
(Ta=25°C)
Unit
Model No.
S101N11
S101N12
S201N11
S201N12
1
S101N11/S201N11
■ Absolute Maximum Ratings
(Unit : mm)
120
Vrms
4 3
2
1
240
1
47 to 63
Hz
2
3
60 to 140
Vout
4
Vrms
Output (Triac T1)
Output (Triac T2)
Input (+)
Input (−)
4 3
2
1
Z.C. : Zero-cross circuit
1 Output (Triac T1)
2 Output (Triac T2)
3 Input (+)
4 Input (−)
❈ Unspecified tolerance : ±0.4mm
60 to 280
IT
Isurge
Topr
Tstg
Viso
Tsol
*1
1.6
15
−25 to +80
−30 to +85
3.0
260
Arms
A
°C
°C
kVrms
°C
*1 Refer to Fig.1
*2 50Hz sine wave, start at Tj=25°C
*3 Isolation voltage measuring method
(1) Dielectric withstand voltage tester with zero cross circuit shall be used.
(2) The applied voltage waveform shall be sine wave.
(3) Voltage shall be applied between input and output.
(Input and output terminals shall be shorted respectively.)
(4) AC 60Hz, 1min, 40 to 60%RH.
*4 For 5s
Notice
In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP
devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/
S101N11/S101N12/S201N11/S201N12
■ Recommended Operating Conditions
Parameter
Input voltage
Input
Output
S101N11
Load supply S101N12
voltage
S201N11
S201N12
Load operating current
Operating frequency
Symbol
VIN
Conditions
−
MIN.
4
TYP.
−
Vout
−
80
−
MAX.
6
120
Vrms
260
Refer to Fig.1
−
0.05
47
−
−
1.6
63
Conditions
−
VD=120Vrms, RL=500Ω
VD=240Vrms, RL=500Ω
VD=120Vrms, RL=500Ω
VD=240Vrms, RL=500Ω
IT=1.6Arms, Resistance load, VIN=3V
VD=120Vrms
VD=240Vrms
MIN.
−
TYP.
160
MAX.
−
(Ta=25°C)
Unit
Ω
−
−
3
V
1
−
−
V
−
−
1.6
Vrms
−
−
mArms
VD=60V, Resistance load, VIN=3V
−
−
VIN=3V, RL=400Ω
−
−
−
−
0.7
1.3
10
20
35
0.5
11
0.5
11
−
−
11
ms
100
−
−
MΩ
−
f
Output
Input
■ Electrical Characteristics
Transfer characteristics
(Ta=25°C)
Unit
V
Parameter
Symbol
Input resistance
RIN
S101N11/S101N12
Pickup voltage
Vpu
S201N11/S201N12
S101N11/S101N12
Dropout voltage
Vdo
S201N11/S201N12
ON-state voltage
VT
Open circuit S101N11/S101N12
Ileak
leak current S201N11/S201N12
S101N11/S101N12
Minimum
IOP
operating current S201N11/S201N12
VOX
Zero-cross voltage S101N12/S201N12
S101N11
S101N12
Turn-on
ton
time
S201N11
S201N12
S101N11/S101N12
Turn-off
toff
time
S201N11/S201N12
Isolation resistance
Riso
VD=120Vrms, AC50Hz, RL=500Ω, VIN=3V
VD=240Vrms, AC50Hz, RL=500Ω, VIN=3V
VD=120Vrms, AC50Hz, RL=500Ω, VIN=3V
VD=240Vrms, AC50Hz, RL=500Ω, VIN=3V
DC500V, 40 to 60%RH
Fig.1 RMS ON-state Current vs. Ambient
Temperature
Arms
Hz
mArms
V
ms
Fig.2 Open Circuit Leak Current vs.
Ambient Temperature (Typical Value)
2.5
2.2
Open circuit leak current Ileak (mArms)
RMS ON-state current IT (Arms)
2.0
2.0
1.6
1.5
1.0
0.5
1.8
1.6
1.2
1.0
0.8
0.6
0.4
0.2
0
−25
20 30 40
60
80
100 120 125 140
Ambient temperature Ta (°C)
S201N11
S201N12
(VD=240Vrms)
1.4
0
−20
S101N11
S101N12
(VD=120Vrms)
0
20
40
60
Ambient temperature Ta (°C)
80
S101N11/S101N12/S201N11/S201N12
Fig.4 Non-repetitive Surge Current vs. Time
Fig.3 Input Current vs. Input Voltage
(Typical Value)
30
25
Ta=25°C
Tj=25°C start
20
Non-repetitive surge current (Apeak)
Input current (mADC)
25
20
15
10
5
0
0
1
2
3
4
5
6
15
10
5
0
0.01
0.1
Input voltage VIN (V)
2.0
3.0
2.7
Pickup voltage
2.1
1.8
Dropout voltage
1.5
1.2
0.9
0.6
0.3
0
−20
10
Fig.6 Maximum ON-state Power Dissipation
vs. RMS ON-state Current
Maximum ON-state power dissipation P (W)
Pickup voltage Vpu (V), dropout voltage Vdo (V)
Fig.5 Pickup Voltage, Dropout Voltage vs.
Ambient Temperature
2.4
1
Time (s)
Ta=25°C
1.8
1.6
1.4
1.2
1.0
0.8
0.6
0.4
0.2
0
0
20
40
60
Ambient temperature Ta (°C)
80
0
0.2 0.4 0.6 0.8
1
1.2 1.4 1.6 1.8
RMS ON-state current IT (Arms)
2
Application Circuits
NOTICE
●The circuit application examples in this publication are provided to explain representative applications of
SHARP devices and are not intended to guarantee any circuit design or license any intellectual property
rights. SHARP takes no responsibility for any problems related to any intellectual property right of a
third party resulting from the use of SHARP's devices.
●Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
SHARP reserves the right to make changes in the specifications, characteristics, data, materials,
structure, and other contents described herein at any time without notice in order to improve design or
reliability. Manufacturing locations are also subject to change without notice.
●Observe the following points when using any devices in this publication. SHARP takes no responsibility
for damage caused by improper use of the devices which does not meet the conditions and absolute
maximum ratings to be used specified in the relevant specification sheet nor meet the following
conditions:
(i) The devices in this publication are designed for use in general electronic equipment designs such as:
--- Personal computers
--- Office automation equipment
--- Telecommunication equipment [terminal]
--- Test and measurement equipment
--- Industrial control
--- Audio visual equipment
--- Consumer electronics
(ii)Measures such as fail-safe function and redundant design should be taken to ensure reliability and
safety when SHARP devices are used for or in connection with equipment that requires higher
reliability such as:
--- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.)
--- Traffic signals
--- Gas leakage sensor breakers
--- Alarm equipment
--- Various safety devices, etc.
(iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely
high level of reliability and safety such as:
--- Space applications
--- Telecommunication equipment [trunk lines]
--- Nuclear power control equipment
--- Medical and other life support equipment (e.g., scuba).
●Contact a SHARP representative in advance when intending to use SHARP devices for any "specific"
applications other than those recommended by SHARP or when it is unclear which category mentioned
above controls the intended use.
●If the SHARP devices listed in this publication fall within the scope of strategic products described in the
Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export
such SHARP devices.
●This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under
the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any
means, electronic or mechanical, for any purpose, in whole or in part, without the express written
permission of SHARP. Express written permission is also required before any use of this publication
may be made by a third party.
●Contact and consult with a SHARP representative if there are any questions about the contents of this
publication.
115