S101N11/S101N12/S201N11/S201N12 S101N11/S101N12 S201N11/S201N12 Voltage Input Type Solid State Relay with Built-in Snubber Circuit ■ Features ■ Outline Dimensions 1. Built-in snubber circuit 2. Input side voltage operation type 3. Built-in zero-cross circuit (S101N12/S201N12) 4. RMS ON-state current IT : MAX. 1.6Arms 26.0MAX. 21.0MAX. (DIN Standard) S101N11 INPUT OUTPUT 5VDC 1.6A120VAC −+ 3.5±0.5 1. Programmable controllers 2. Copiers 3. Air conditioners 4. Automatic vending machines ∼ 2.54 2.54 ■ Model line-ups 0.5 10.16 4 3 For 100V lines S101N11 S101N12 5.5MAX. Lot No. ■ Applications No zero-cross circuit Built-in zero-cross circuit 1.3±0.3 7.62 2 For 200V lines S201N11 S201N12 Internal connection diagram Input Output S101N11 Output S101N12 supply voltage S201N11 S201N12 RMS ON-state current Peak one cycle surge current Operating temperature Storage temperature *3 Isolation voltage *4 Soldering temperature *2 Rating 3 to 6 6 V V S101N12/S201N12 Z.C. Parameter Symbol Input signal voltage VIN Reverse voltage VR S101N11 Standard S101N12 − voltage S201N11 S201N12 Operating frequency f (Ta=25°C) Unit Model No. S101N11 S101N12 S201N11 S201N12 1 S101N11/S201N11 ■ Absolute Maximum Ratings (Unit : mm) 120 Vrms 4 3 2 1 240 1 47 to 63 Hz 2 3 60 to 140 Vout 4 Vrms Output (Triac T1) Output (Triac T2) Input (+) Input (−) 4 3 2 1 Z.C. : Zero-cross circuit 1 Output (Triac T1) 2 Output (Triac T2) 3 Input (+) 4 Input (−) ❈ Unspecified tolerance : ±0.4mm 60 to 280 IT Isurge Topr Tstg Viso Tsol *1 1.6 15 −25 to +80 −30 to +85 3.0 260 Arms A °C °C kVrms °C *1 Refer to Fig.1 *2 50Hz sine wave, start at Tj=25°C *3 Isolation voltage measuring method (1) Dielectric withstand voltage tester with zero cross circuit shall be used. (2) The applied voltage waveform shall be sine wave. (3) Voltage shall be applied between input and output. (Input and output terminals shall be shorted respectively.) (4) AC 60Hz, 1min, 40 to 60%RH. *4 For 5s Notice In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that may occur in equipment using any SHARP devices shown in catalogs, data books, etc. Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. Internet Internet address for Electronic Components Group http://www.sharp.co.jp/ecg/ S101N11/S101N12/S201N11/S201N12 ■ Recommended Operating Conditions Parameter Input voltage Input Output S101N11 Load supply S101N12 voltage S201N11 S201N12 Load operating current Operating frequency Symbol VIN Conditions − MIN. 4 TYP. − Vout − 80 − MAX. 6 120 Vrms 260 Refer to Fig.1 − 0.05 47 − − 1.6 63 Conditions − VD=120Vrms, RL=500Ω VD=240Vrms, RL=500Ω VD=120Vrms, RL=500Ω VD=240Vrms, RL=500Ω IT=1.6Arms, Resistance load, VIN=3V VD=120Vrms VD=240Vrms MIN. − TYP. 160 MAX. − (Ta=25°C) Unit Ω − − 3 V 1 − − V − − 1.6 Vrms − − mArms VD=60V, Resistance load, VIN=3V − − VIN=3V, RL=400Ω − − − − 0.7 1.3 10 20 35 0.5 11 0.5 11 − − 11 ms 100 − − MΩ − f Output Input ■ Electrical Characteristics Transfer characteristics (Ta=25°C) Unit V Parameter Symbol Input resistance RIN S101N11/S101N12 Pickup voltage Vpu S201N11/S201N12 S101N11/S101N12 Dropout voltage Vdo S201N11/S201N12 ON-state voltage VT Open circuit S101N11/S101N12 Ileak leak current S201N11/S201N12 S101N11/S101N12 Minimum IOP operating current S201N11/S201N12 VOX Zero-cross voltage S101N12/S201N12 S101N11 S101N12 Turn-on ton time S201N11 S201N12 S101N11/S101N12 Turn-off toff time S201N11/S201N12 Isolation resistance Riso VD=120Vrms, AC50Hz, RL=500Ω, VIN=3V VD=240Vrms, AC50Hz, RL=500Ω, VIN=3V VD=120Vrms, AC50Hz, RL=500Ω, VIN=3V VD=240Vrms, AC50Hz, RL=500Ω, VIN=3V DC500V, 40 to 60%RH Fig.1 RMS ON-state Current vs. Ambient Temperature Arms Hz mArms V ms Fig.2 Open Circuit Leak Current vs. Ambient Temperature (Typical Value) 2.5 2.2 Open circuit leak current Ileak (mArms) RMS ON-state current IT (Arms) 2.0 2.0 1.6 1.5 1.0 0.5 1.8 1.6 1.2 1.0 0.8 0.6 0.4 0.2 0 −25 20 30 40 60 80 100 120 125 140 Ambient temperature Ta (°C) S201N11 S201N12 (VD=240Vrms) 1.4 0 −20 S101N11 S101N12 (VD=120Vrms) 0 20 40 60 Ambient temperature Ta (°C) 80 S101N11/S101N12/S201N11/S201N12 Fig.4 Non-repetitive Surge Current vs. Time Fig.3 Input Current vs. Input Voltage (Typical Value) 30 25 Ta=25°C Tj=25°C start 20 Non-repetitive surge current (Apeak) Input current (mADC) 25 20 15 10 5 0 0 1 2 3 4 5 6 15 10 5 0 0.01 0.1 Input voltage VIN (V) 2.0 3.0 2.7 Pickup voltage 2.1 1.8 Dropout voltage 1.5 1.2 0.9 0.6 0.3 0 −20 10 Fig.6 Maximum ON-state Power Dissipation vs. RMS ON-state Current Maximum ON-state power dissipation P (W) Pickup voltage Vpu (V), dropout voltage Vdo (V) Fig.5 Pickup Voltage, Dropout Voltage vs. Ambient Temperature 2.4 1 Time (s) Ta=25°C 1.8 1.6 1.4 1.2 1.0 0.8 0.6 0.4 0.2 0 0 20 40 60 Ambient temperature Ta (°C) 80 0 0.2 0.4 0.6 0.8 1 1.2 1.4 1.6 1.8 RMS ON-state current IT (Arms) 2 Application Circuits NOTICE ●The circuit application examples in this publication are provided to explain representative applications of SHARP devices and are not intended to guarantee any circuit design or license any intellectual property rights. SHARP takes no responsibility for any problems related to any intellectual property right of a third party resulting from the use of SHARP's devices. ●Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device. SHARP reserves the right to make changes in the specifications, characteristics, data, materials, structure, and other contents described herein at any time without notice in order to improve design or reliability. Manufacturing locations are also subject to change without notice. ●Observe the following points when using any devices in this publication. SHARP takes no responsibility for damage caused by improper use of the devices which does not meet the conditions and absolute maximum ratings to be used specified in the relevant specification sheet nor meet the following conditions: (i) The devices in this publication are designed for use in general electronic equipment designs such as: --- Personal computers --- Office automation equipment --- Telecommunication equipment [terminal] --- Test and measurement equipment --- Industrial control --- Audio visual equipment --- Consumer electronics (ii)Measures such as fail-safe function and redundant design should be taken to ensure reliability and safety when SHARP devices are used for or in connection with equipment that requires higher reliability such as: --- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.) --- Traffic signals --- Gas leakage sensor breakers --- Alarm equipment --- Various safety devices, etc. (iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely high level of reliability and safety such as: --- Space applications --- Telecommunication equipment [trunk lines] --- Nuclear power control equipment --- Medical and other life support equipment (e.g., scuba). ●Contact a SHARP representative in advance when intending to use SHARP devices for any "specific" applications other than those recommended by SHARP or when it is unclear which category mentioned above controls the intended use. ●If the SHARP devices listed in this publication fall within the scope of strategic products described in the Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export such SHARP devices. ●This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any means, electronic or mechanical, for any purpose, in whole or in part, without the express written permission of SHARP. Express written permission is also required before any use of this publication may be made by a third party. ●Contact and consult with a SHARP representative if there are any questions about the contents of this publication. 115