MA-COM CHB-38

Catalog 1308242
Issued 3-03
P&B
CH series
Mid- To Low-Priced
CMOS IC Time Delay Relay
• Choice of timing modes
– Delay on operate
– Delay on release
– Interval on
• Fixed or knob adjustable types
• 10A output relay with DPDT contacts
• Various models time from 1 to 180 sec.
File E22575
File LR15734
Users should thoroughly review the technical data before selecting a product part
number. It is recommended that user also seek out the pertinent approvals files of
the agencies/laboratories and review them to ensure the product meets the
requirements for a given application.
Contact Data @ 25°C
Timing Modes
Delay on operate – Delay period begins when input voltage is applied. At
the end of the delay period, the relay will operate and will not release until
input voltage is removed. Reset occurs when input voltage is reapplied.
INPUT
VOLTAGE
ON
OFF
N.O. RELAY ON
CONTACTS OFF
Arrangements: 2 Form C (DPDT).
Material: Silver-cadmium oxide alloy.
Rating: 10A @ 30VDC or 277VAC, resistive; 1/2 HP @ 250VAC; 1/3 HP @
120VAC.
Expected Mechanical Life: 10 million operations.
Expected Electrical Life: 100,000 operations, min., at rated load.
TIME
Initial Dielectric Strength
Delay on release – Input voltage must be applied continuously to operate
the internal relay. When the control switch is closed, the relay energizes.
When the control switch is opened, timing begins. When timing is
complete, the relay will de-energize. Time may be reset to zero during
timing by closing the control switch.
CONTROL
SWITCH
ON
OFF
N.O. RELAY ON
CONTACTS OFF
TIME
Between Open Contacts: 500V rms, 60 Hz.
Between All Other Conductors: 500V rms, 60 Hz.
Input Data @ 25°C
Voltage: 24 through 240VAC and 24VDC.
Power Requirement: AC Types: Typically less than 3 VA.
DC Types: Typically less than 3 W.
Transient Protection: Yes.
Reverse Voltage Protection: Yes.
Input Voltages & Limits @ 25°C
Interval on – The relay energizes and timing begins when input voltage is
applied. At the end of the time delay period the relay will de-energize.
Reset is accomplished by removing, then reapplying, the input voltage.
INPUT
VOLTAGE
ON
OFF
N.O. RELAY ON
CONTACTS OFF
Voltage
Type
Nominal
Voltage
Minimum
Voltage
Maximum
Voltage
AC
24
120
240
24
20
105
210
20
28
130
260
32
DC
Note: DC voltage must be filtered (5% p-p ripple max. at nom. voltage).
AC models will operate on 50 or 60 Hz.
TIME
Environmental Data
Timing Specifications
Timing Ranges: From 1 to 180 sec.
Timing Adjustment: Fixed and knob adjustable.
Tolerance (for AC units add ±1/2 cycle 60 Hz.):
Knob Adj. Types:–0, +20% of max. specified at high end of timing range;
min. specified, or less, at low end.
Fixed Types:
± 5%.
Res. Adj. Types: ± 5% at high end of timing range; min. specified, or less,
at low end.
Delta Time (for AC units add ±1 cycle 60 Hz.): ± 10%.
Repeatability (for AC units add ±1 cycle 60 Hz.): ± 2%.
Release Time: 125 ms, typ.; 200 ms, max.
Recycle Time: 125 ms, typ.; 200 ms, max.
Dimensions are shown for
1226 reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Temperature Range: Storage: -55°C to +85°C.
Operating: -10°C to +55°C.
Mechanical Data
Termination: 8- or 11-pin octal style plug.
Enclosure: White plastic case. Knob adjustable types have dial scale for
reference only.
Sockets: Models with 8-pin base fit either 27E122 or 27E891 (snap-on)
screw terminal sockets. 11-pin types fit either 27E123 or
27E892 (snap-on) screw terminal sockets.
Weight: 6 oz. (170g) approximately.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
Refer to inside back cover.
Catalog 1308242
Issued 3-03
P&B
Ordering Information – Authorized distributors are more likely to stock boldface items listed below.
Delay on Operate Models
Voltage
Time
24VAC
1 to 10 Sec.
1 to 180 Sec.
Delay on Release Models
Adjustment
Wiring Dia.
Part Number
Voltage
Time
Adjustment
Wiring Dia.
Part Number
Knob
1
CHB-38-30001
CHB-38-30003
24VAC
1 to 10 Sec.
Knob
3
CHB-38-30011
120VAC
1 to 10 Sec.
1 to 60 Sec.
1 to 180 Sec.
Knob
3
CHB-38-70011
CHB-38-70012
CHB-38-70013
Knob
3
Adjustment
Wiring Dia.
Part Number
120VAC
1 to 10 Sec.
1 to 60 Sec.
1 to 180 Sec.
Knob
1
CHB-38-70001
CHB-38-70002
CHB-38-70003
120VAC
10 Sec.
Fixed
1
CHA-38-70001
240VAC
1 to 10 Sec.
Knob
1
CHB-38-80001
24VDC
1 to 10 Sec.
1 to 60 Sec.
1 to 180 Sec.
Knob
1
CHD-38-30001
CHD-38-30002
CHD-38-30003
24VDC
1 to 10 Sec.
1 to 180 Sec.
CHD-38-30011
CHD-38-30013
Interval on Models
Voltage
Time
120VAC
1 to 10 Sec.
1 to 60 Sec.
1 to 180 Sec.
Knob
1
CHB-38-70021
CHB-38-70022
CHB-38-70023
24VDC
1 to 10 Sec.
Knob
1
CHD-38-30021
➛
Outline Dimensions
2.406 MAX.
(61.1)
➛
2.937 MAX.
(74.6)
➛
➛
➛
➛
.56
(14.2)
➛
.60
(15.2)
1.781 MAX.
(45.2)
➛
Wiring Diagrams – Bottom Views (pins numbered clockwise from keyway)
EXTERNAL RESISTOR
Fig. 2
11 Pin
➛
➛
Fig. 1
8 Pin
➛
➛
➛
+
INPUT
(DC POLARITY INDICATED)
➛
_
+ INPUT _
(DC POLARITY INDICATED)
➛
➛
➛
➛
➛
➛
EXT SWITCH*
+
-
AC INPUT
Fig. 3
11 Pin
* If control switch is closed when power is applied, relay will immediately energize. A 50 millisecond minimum switch closure is required. IMPORTANT: A dry circuit switch is recommended. A
“dry circuit” switch is one rated to reliably switch currents of less than 50mA. Use of a switch rated for other than dry circuit may result in failure of the time delay relay to function properly.
** Note: Input polarity for DC operation. For most reliable operation on AC, connect high side to “+” and low side to “–”.
Dimensions are shown for
reference purposes only.
Dimensions are in inches over
(millimeters) unless otherwise
specified.
Specifications and availability
subject to change.
www.tycoelectronics.com
Technical support:
1227
Refer to inside back cover.