VICOR MT036A015M080FP

MIL-COTS PRMTM Regulator and VTMTM Current Multiplier Modules
• Small footprint: 1.64 and 2.08 in2
• 16 – 50 Vin
• 1 – 50 Vout
• Up to 120 W of output
• High efficiency up to 96.5%
• Low profile 0.37” flanged model
• Power density: Up to 156 W/in3
• Flexible architecture
• Low noise
• Fast transient response
Features
• -55°C to 100°C baseplate
• Sine Amplitude Converter (VTM)
• ZVS buck-boost regulator (PRM)
• Regulation 1% (Adaptive Loop)
PRM Model
Number
Input Voltage
(V)
MR028A036M012FP
[a]
MIL-COTS VI BRICK PRM and VTM modules
provide the technical advantages of Factorized
Power including high density and efficiency,
low noise operation, architectural flexibility,
extremely fast transient response, and
elimination of bulk capacitance at the point-ofload (POL). Utilizing baseplate and integrated
heat sink packaging, the platform also provides
improved thermal management and
through-hole mounting capability in a
small, robust package.
Regulation (%)
Efficiency (%)
Output Voltage
(V)
Output Power
(W)
Line
Load
50% Load
100% Load
26 - 50
120
0.10
0.10
92.5
95.0
[a]
will operate down to 13.5 V after start up ≥16 V
No Load Output Voltage (V)
VTM Model
Number
K-Factor
MT036A011M100FP
MT036A015M080FP
MT036A022M055FP
MT036A030M040FP
MT036A045M027FP
MT036A060M020FP
MT036A072M017FP[a]
MT036A090M013FP
MT036A120M010FP
MT036A180M007FP
MT036A240M005FP
MT036A360M003FP
[a]
16 - 50
Product Description
1/32
1/24
1/16
1/12
1/8
1/6
1/5
1/4
1/3
1/2
2/3
1
Efficiency at nom Vout (%)
26 Vin
50 Vin
Output Current
(A)
50% Load
100% Load
0.82
1.1
1.6
2.2
3.3
4.3
6.4[a]
6.5
8.7
13.0
17.4
26.0
1.55
2.0
3.1
4.1
6.2
8.3
10.0
12.5
16.6
25.0
33.0
50.0
100
80
55
40
27
20
16.6
13.3
10.0
6.7
5.0
3.3
91.5
94.0
94.5
95.0
96.5
96.8
96.5
95.5
95.5
95.2
95.4
96.0
89.5
92.0
94.0
94.0
95.3
95.3
96.5
96.3
95.5
96.0
95.6
96.0
Low line input voltage 32 V
Typical Application
Vo = VL ± 1.0%
VC
PC
TM
IL
NC
PR
+IN
VH
SC
SG
OS
NC
CD
PRM
+OUT
Vin
-IN
-OUT
ROS
RCD
Factorized
Bus (Vf)
VL (Io•Ro)
Vf =
+
K
K
+IN
+OUT
-OUT
TM
VC
PC
-IN
VTM
+OUT
-OUT
L
O
A
D
Figure 1 — Typical application with Adaptive Loop control, the output of the VTM is regulated over the load current range with only a single interconnect
between the PRM and VTM and without the need for isolation in the feedback path.
VI BRICK: MIL-COTS PRMTM Regulator and VTMTM Current Multiplier Modules
vicorpower.com
Rev. 1.0
Page 1 of 2
VI BRICK PRM Mechanical Drawing
Baseplate - Slotted Flange
Recommended
PCB Pattern
Heat Sink (Transverse)
(Component side shown)
VI BRICK VTM Mechanical Drawing
Baseplate - Slotted Flange
Recommended
PCB Pattern
Heat Sink (Transverse)
(Component side shown)
The products described on this document are protected by the following U.S. Patents Numbers: PRMs: 5,945,130; 6,403,009; 6,710,257; 6,788,033; 6,940,013; 6,969,909; 7,038,917;
7,154,250; 7,166,898; 7,187,263; D496,906; D506,438; D509,472; and for use under 6,975,098 and 6,984,965 VTMs: 5,945,130; 6,403,009; 6,710,257; 6,911,848; 6,930,893;
6,934,166; 6,940,013; 6,969,909; 7,038,917; 7,145,186; 7,166,898; 7,187,263; D496,906; D505,114; D506,438; D509,472; and for use under 6,975,098 and 6,984,965
VI BRICK: MIL-COTS PRMTM Regulator and VTMTM Current Multiplier Modules
vicorpower.com
Rev. 1.0
Page 2 of 2