VICOR B384F120T30

6,73
0.265
V•I Chip BCM
HV Bus Converter Family
TM
TM
• Efficiency: 95% Typical
–In
+In
PC RSV TM
™ VICOR CORP.
MADE IN USA
• Current sharing: 5%
VIB0003TFJ
BCM
™
AP4141PRS724558
S
22,0
0.87
RoHS
• Input: HV 270 / 350 / 380 V
C
• Isolation: 4,242 Vdc
3
–Out
2
• Power Density: >1000 W/in
NRTL
US
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
• Footprint: 1.1 in
+Out
–Out
32,5
1.28
+Out
Actual size
mm
in
Product Description
The HV Bus Converter Module family consists of six models that provide an isolated intermediate bus voltage to power non-isolated
POL converters. The HV BCMs offer direct conversion from PFC bus voltage to 12 V POL at up to 300 W with isolation to 4,242
Vdc. The HV family provides superior performance, the highest efficiency and power density in the smallest package available.
Input
Voltage
(V)
Output
Voltage
(V)
Output
Power
(W)
Output
Current
(A)
Temp.
Grade
Package
B352F110T24
330 – 365
10.3 – 11.4
240
24.0
T
Full
B384F120T30
360 – 400
11.25 – 12.5
300
25.0
T
Full
VIB0001TFJ
330 – 365
10.3 – 11.4
300
28.0
T
Full
VIB0002TFJ
360 – 400
45.0 – 50.0
300
7.0
T
Full
VIB0003TFJ
330 – 365
41.25 – 45.62
325
7.7
T
Full
VMB0004MFJ
240 – 330
30.0 – 41.25
240
7.3
MIL COTS
Full
Model
Number*
* Products are also available in through-hole model. See individual datasheets.
LOAD
POL
–Out
US
+Out
–Out
12 V
+Out
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
S
NRTL
C
RoHS
™
BCM
–In
HV
PC RSV TM
+In
™ VICOR CORP.
MADE IN USA
Typical Applications
vicorpower.com
+Out
–Out
+Out
0.8 – 55 V
LOAD
–Out
US
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
S
VTM
™
Rev. 1.3
NRTL
C
RoHS
+In
™ VICOR CORP.
MADE IN USA
PC VC TM
–In
US
CD NC OS SG SC VH
+Out
–Out
S
NRTL
C
RoHS
™
PRM
800-735-6200
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
PR NC IL TM PC VC
™ VICOR CORP.
MADE IN USA
+In
48 V
–In
+Out
–Out
–Out
+Out
™
BCM
U.S. PATS. LISTED ON PACKING MATERIALS & DATASHEETS
US
NRTL
RoHS
C
S
+In
PC RSV TM
–In
HV
™ VICOR CORP.
MADE IN USA
LOAD
9/2009
Page 1 of 2
General Specifications
Parameter
MTBF
MIL-HDBK-217F
Isolation
Voltage
Capacitance
Resistance
Regulatory compliance
Thermal
Over temperature shutdown
Case-to-ambient thermal impedance
Operating junction temperature
Operating junction temperature
Storage temperature
Typ
Unit
Note
3.5
Mhrs
25°C, GB
4,242
500–660
10
cTÜVus
CE Mark
RoHS
Vdc
pF
MΩ
Input to output (basic insulation)
Input to output
Input to output
UL /CSA 60950, EN60950
Low voltage directive
125
3.7
-40 to 125
-55 to 125
-40 to 125
°C
°C / W
°C
°C
°C
minimum, junction temperature
with 0.25” heat sink @ 300 LFM
T–Grade
MIL–COTS
BCM Mechanical Outline Drawing*
Heat Sink Push-Pin Hole Pattern
2.95±0.07
ø
(2) PL
[0.116±0.003]
NON-PLATED
THROUGH HOLE
SEE NOTE 1.
(4.37)
0.172
(11.37)
0.448
(36.50)
1.437
(18.25)
0.719
DOTTED LINE
INDICATES VIC
POSITION
SEE NOTE 3
(7.00)
0.276
BOTTOM VIEW
(2.510)
0.099
(31.48)
1.240
(39.50)
1.555
SEE NOTE 2.
HEAT SINK PUSH-PIN HOLE PATTERN
( TOP SIDE SHOWN )
SEE NOTE 3
RECOMMENDED LAND PATTERN
( COMPONENT SIDE SH OWN )
NOTES:
1. MAINTAIN 3.5/[0.138] DIA. KEEP OUT ZONE FREE OF
COPPER. ALL PCB LAYERS.
2. MINIMUM RECOMMENDED PITCH IS 39.50/[1.555].
THIS PROVIDES 7.00/[0.276] COMPONENT EDGE-TO-EDGE SPACING.
AND 0.50/[0.020] CLEARANCE BETWEEN VICOR HEAT SINKS.
NOTES:
mm
1. DIMENSIONS ARE inch .
2. UNLESS OTHERWISE SPECIFIED, TOLERANCES ARE:
.X / [.XX] = +/-0.25 / [.01]; .XX / [.XXX] = +/-0.13 / [.005]
3. PRODUCT MARKING ON TOP SURFACE
DXF and PDF files are available on vicorpower.com
TOP VIEW ( COMPONENT SIDE )
3. V•I CHIP LAND PATTERN SHOWN FOR REFERENCE ONLY;
ACTUAL LAND PATTERN MAY DIFFER.
DIMENSIONS FROM EDGES OF LAND PATTERN TO PUSH-PIN
HOLES WILL BE THE SAME FOR ALL FULL SIZE V•I CHIPS.
(mm)
4. DIMENSION ARE inch .
* For through–hole mechanical drawing see individual datasheets.
The products described on this data sheet are protected by the following U.S. Patents Numbers: 5,945,130; 6,403,009; 6,710,257; 6,911,848; 6,930,893; 6,934,166; 6,940,013;
6,969,909; 7,038,917; 7,166,898; 7,187,263; 7,361,844; D496,906; D505,114; D506,438; D509,472 and for use under 6,975,098 and 6,984,965
vicorpower.com
800-735-6200
Rev. 1.3
9/2009
Page 2 of 2