New Product UH10FT & UHB10FT Vishay General Semiconductor Ultrafast Recovery Rectifier FEATURES • Oxide planar chip junction TO-220AC TO-263AB • Ultrafast recovery times • Soft recovery characteristics K • Low switching losses, high efficiency • High forward surge capability A 2 NC 1 UH10FT PIN 1 NC CASE PIN 2 • Meets MSL level 1, per J-STD-020, LF maximum peak of 245 °C (for TO-263AB package) UHB10FT K • Solder dip 260 °C, 40 s (for TO-220AC package) HEATSINK A • Component in accordance to RoHS 2002/95/EC and WEEE 2002/96/EC TYPICAL APPLICATIONS For use in high frequency rectification and freewheeling application in switching mode converter and inverter for consumer. PRIMARY CHARACTERISTICS IF(AV) 10 A VRRM 300 V IFSM 180 A trr 25 ns VF 0.83 V TJ max. 175 °C MECHANICAL DATA Case: TO-220AC and TO-263AB Epoxy meets UL 94V-0 flammability rating Terminals: Matte tin plated leads, solderable per J-STD-002 and JESD22-B102 E3 suffix for consumer grade, meets JESD 201 class 1A whisker test Polarity: As marked Mounting Torque: 10 in-lbs maximum MAXIMUM RATINGS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL UH10FT UHB10FT UNIT Maximum repetitive peak reverse voltage VRRM 300 V Maximum average forward rectified current (Fig. 1) IF(AV) 10 A Peak forward surge current 10 ms single half sine-wave superimposed on rated load IFSM 180 A TJ, TSTG - 55 to + 175 °C Operating junction and storage temperature range Document Number: 88963 Revision: 13-May-08 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 1 New Product UH10FT & UHB10FT Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TYP. MAX. UNIT 0.96 0.77 - 1.0 0.83 1.2 0.90 IR 0.5 25 5 150 µA IF = 5.0 A IF = 5.0 A TJ = 25 °C TJ = 125 °C IF = 10 A IF = 10 A TJ = 25 °C TJ = 125 °C Maximum reverse current (2) VR = 300 V TJ = 25 °C TJ = 125 °C Maximum reverse recovery time IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A trr 20 25 ns Maximum reverse recovery time IF = 1.0 A, dI/dt = 50 A/µs, VR = 30 V, Irr = 0.1 IRM trr 28 35 ns S 0.36 - - Maximum instantaneous forward voltage (1) Typical softness factor (tb/ta) Typical reverse recovery current IF = 10 A, dI/dt = 200 A/µs, VR = 200 V, TJ = 125 °C Typical stored charge Typical forward recovery time IF = 10 A, dI/dt = 80 A/µs, VFR = 1.1 x VF max. VF V IRM 7.0 - ns Qrr 160 - A tfr 150 - ns SYMBOL UH10FT UHB10FT UNIT RθJC 2.0 2.0 °C/W Notes: (1) Pulse test: 300 µs pulse width, 1 % duty cycle (2) Pulse test: Pulse width ≤ 40 ms THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER Typical thermal resistance ORDERING INFORMATION (Example) PACKAGE PREFERRED P/N UNIT WEIGHT (g) PACKAGE CODE BASE QUANTITY DELIVERY MODE TO-220AC UH10FT-E3/4W 1.82 4W 50/tube Tube TO-263AB UHB10FT-E3/4W 1.32 4W 50/tube Tube TO-263AB UHB10FT-E3/8W 1.32 8W 800/reel Tape and reel www.vishay.com 2 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] Document Number: 88963 Revision: 13-May-08 New Product UH10FT & UHB10FT Vishay General Semiconductor RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted) 100 Instantaneous Forward Current (A) 15 Average Forward Current (A) Resistive or Inductive Load 12 9 6 3 25 50 75 125 150 175 TJ = 25 °C 1 Instantaneous Forward Voltage (V) Figure 1. Maximum Forward Current Derating Curve Figure 4. Typical Instantaneous Forward Characteristics 12 1000 10 Instantaneous Reverse Current (µA) D = 0.8 D = 0.5 D = 0.3 9 D = 0.2 8 D = 1.0 D = 0.1 7 6 5 T 4 3 2 1 D = tp/T tp 8 10 0 100 TJ = 175 °C 10 TJ = 125 °C 1 0.1 TJ = 25 °C 0.01 0.001 0 2 4 6 12 10 20 30 40 50 60 70 80 90 100 Average Forward Current (A) Percent of Rated Peak Reverse Voltage (%) Figure 2. Forward Power Loss Characteristics Figure 5. Typical Reverse Leakage Charactersitics 200 1000 TJ = 25 °C f = 1.0 MHz Vsig = 50 mVp-p TJ = TJ Max. 10 ms Single Half Sine-Wave 180 Junction Capacitance (pF) Peak Forward Surge Current (A) TJ = 175 °C TC - Case Temperature (°C) 11 Average Power Loss (W) 100 10 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3 1.4 1.5 0 0 TJ = 125 °C 160 140 120 100 80 60 100 10 40 20 1 10 100 1 0.1 1 10 100 Number of Cycles Reverse Voltage (V) Figure 3. Maximum Non-Repetitive Peak Forward Surge Current Figure 6. Typical Junction Capacitance Document Number: 88963 Revision: 13-May-08 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 3 New Product UH10FT & UHB10FT Vishay General Semiconductor PACKAGE OUTLINE DIMENSIONS in inches (millimeters) TO-220AC 0.415 (10.54) MAX. 0.370 (9.40) 0.360 (9.14) 0.154 (3.91) DIA. 0.148 (3.74) DIA. 0.185 (4.70) 0.175 (4.44) 0.055 (1.39) 0.045 (1.14) 0.113 (2.87) 0.103 (2.62) 0.145 (3.68) 0.135 (3.43) 0.635 (16.13) 0.625 (15.87) 1 PIN 0.603 (15.32) 0.573 (14.55) 0.350 (8.89) 0.330 (8.38) 1.148 (29.16) 1.118 (28.40) 2 0.160 (4.06) 0.140 (3.56) 0.110 (2.79) 0.100 (2.54) 0.057 (1.45) 0.045 (1.14) 0.560 (14.22) 0.530 (13.46) PIN 1 CASE PIN 2 0.105 (2.67) 0.095 (2.41) 0.037 (0.94) 0.027 (0.68) 0.205 (5.20) 0.195 (4.95) 0.022 (0.56) 0.014 (0.36) TO-263AB 0.411 (10.45) 0.380 (9.65) 0.190 (4.83) 0.160 (4.06) 0.245 (6.22) MIN. 0.055 (1.40) 0.045 (1.14) Mounting Pad Layout 0.42 (10.66) MIN. K 0.360 (9.14) 0.320 (8.13) NC K A 0.624 (15.85) 0.591 (15.00) 0 to 0.01 (0 to 0.254) 0.110 (2.79) 0.090 (2.29) 0.021 (0.53) 0.014 (0.36) 0.037 (0.940) 0.027 (0.686) 0.105 (2.67) 0.095 (2.41) www.vishay.com 4 0.055 (1.40) 0.047 (1.19) 0.205 (5.20) 0.195 (4.95) 0.140 (3.56) 0.110 (2.79) 0.33 (8.38) MIN. 0.670 (17.02) 0.591 (15.00) 0.15 (3.81) MIN. 0.08 (2.032) MIN. 0.105 (2.67) 0.095 (2.41) For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] Document Number: 88963 Revision: 13-May-08 Legal Disclaimer Notice Vishay Disclaimer All product specifications and data are subject to change without notice. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product. Vishay disclaims any and all liability arising out of the use or application of any product described herein or of any information provided herein to the maximum extent permitted by law. The product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein, which apply to these products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. The products shown herein are not designed for use in medical, life-saving, or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay for any damages arising or resulting from such use or sale. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 18-Jul-08 www.vishay.com 1