SCHRACK General Purpose Relays Miniature Power PCB Relay PCH n 1pole 5 A, 1CO or 1NO contact n Sensitive 200 mW coil available n Version PCH-WG with tracking resistance PTI 250 on relay base and cover n WG version: Product in accordance to IEC60335-1 Applications Domestic appliances, heating control, building control, measurement & control F_PCH_B Approvals PCH / PCH-WG: V 119568 Z E82292 Technical data of approved types on request Contact data PCH Contact configuration Contact set Type of interruption Rated voltage / max. switching voltage AC Rated current Limiting continuous current Maximum breaking capacity AC Contact material Rated frequency of operation with / without load Operate- / release time Bounce time NO contact Contact ratings Type Contact IEC 61810 PCH-…2M-WG PCH-…D2-WG PCH-…D2M PCH-…L2M PCH-…D2 UL 508 PCH PCH-WG 1 CO or 1 NO single contact micro-disconn. 250 / 400 VAC 5A 5 A, UL: 10 A 1250 VA AgSnO2 6/600 min-1 max. 10/5 ms max. 10 ms Load Ambient temp. [°C] Cycles NO NO of CO NO NO CO 5 A, 250 VAC, cosϕ=1 5 A, 250 VAC, cosϕ=1 5 A, 250 VAC, cosϕ=1 5 A, 250 VAC, cosϕ=1 5 A/3 A, 250 VAC, cosϕ=1 85°C 85°C 70°C 70°C 40°C 100x103 100x103 100x103 30x103 30x103 NO 5 A, 250 VAC, general use 85°C 100x103 Coil data standard sensitiv Rated coil voltage range DC coil Operative range to IEC 61810 Coil insulation system according UL1446 5...48 VDC 5...24 VDC 1 class F Coil versions, DC-coil - standard Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 05 5 3.75 0.5 62.5+10% 400 06 6 4.5 0.6 80+10% 400 09 9 6.3 0.9 202.5+10% 400 12 12 8.4 1.2 360+10% 400 24 24 16.8 2.4 1440+10% 400 48 48 33.6 4.8 5760+10% 400 All figures are given for coil without preenergization, at ambient temperature +23°C Other coil voltages on request 1 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. SCHRACK General Purpose Relays Miniature Power PCB Relay PCH (Continued) Coil versions, DC-coil - sensitive Coil Rated Operate Release Coil Rated coil code voltage voltage voltage resistance power VDC VDC VDC Ohm mW 05 5 3.75 0.5 125+10% 200 06 6 4.5 0.6 180+10% 200 09 9 6.75 0.9 400+10% 200 12 12 9.0 1.2 720+10% 200 24 24 18.0 2.4 2800+10% 200 All figures are given for coil without preenergization, at ambient temperature +23°C Other coil voltages on request PCB layout / terminal assignment Bottom view on solder pins Insulation Dielectric strength coil-contact circuit open contact circuit Clearance / creepage coil-contact circuit NO: CO: Material group of insulation parts Tracking index of relay base, standard version WG-version Insulation to IEC 61810-1 Type of insulation coil-contact circuit open contact circuit Rated insulation voltage Pollution degree Rated voltage system Overvoltage category 4000 Vrms 1000 Vrms S0550-AA 5.5 / 9 mm 4.5 / 9 mm IIIa PTI 175 PTI 250 basic micro disconnection 250 V 3 230 / 400 V III S0550-AB Other data Mechanical endurance, standard version 1.5x106 cycles WG version 10x106 cycles Material RoHS - Directive 2002/95/EC compliant as per product date code 0424 Resistance to heat and fire, WG-version according EN60335, par.30 Environment Ambient temperature range all WG-versions: -40...85°C Standard NO: -30...70°C Standard CO: -30...40°C Vibration resistance (function) NO / NC contact >14 / 8 g, 30...400 Hz Shock resistance (destruction) 100 g Category of protection RTII - flux proof RTIII - wash tight Processing Mounting PCB Resistance to soldering heat flux-proof version 270°C / 10 s wash-tight version 260°C / 5 s Relay weight 7g Packaging unit 25/1000 pcs S0550-AC Dimensions S0551-B 2 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change. SCHRACK General Purpose Relays Miniature Power PCB Relay PCH (Continued) Product key Typical product key PCH -1 12 D 2 Type PCH Miniature PCB Relay RE Version 1 1 pole Coil 05 5 VDC 06 6 VDC 09 9 VDC Coil power D standard 400 mW Contact material 2 AgSnO2 Contact configuration Blank 1 CO contact (1 form C) Enclosure Blank flux proof Version Blank standard version Other types on request Product Key PCH-105D2M PCH-106D2M PCH-109D2M PCH-112D2M PCH-124D2M PCH-148D2M PCH-105D2 PCH-106D2 PCH-109D2 PCH-112D2 PCH-124D2 PCH-148D2 PCH-105L2M PCH-106L2M PCH-109L2M PCH-112L2M PCH-124L2M PCH-105D2M-WG PCH-106D2M-WG PCH-109D2M-WG PCH-112D2M-WG PCH-124D2M-WG PCH-148D2M-WG PCH-105D2-WG PCH-106D2-WG PCH-109D2-WG PCH-112D2-WG PCH-124D2-WG PCH-148D2-WG PCH-105L2M-WG PCH-106L2M-WG PCH-109L2M-WG PCH-112L2M-WG PCH-124L2M-WG Version flux proof standard 12 24 48 12 VDC 24 VDC 48 VDC L sensitive 200 mW (for NO contact only) M 1 NO contact (1 form A) H wash tight WG Product in accordance with IEC 60335-1 (domestic appliances) Contact material AgSnO2 Contacts 1 NO contact 1 CO contact flux proof sensitive 1 NO contact flux proof standard materials according IEC 60335-1 1 CO contact flux proof sensitive materials according IEC 60335-1 1 NO contact Coil 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC 48 VDC 5 VDC 6 VDC 9 VDC 12 VDC 24 VDC Part number 1461350-2 1461350-3 1461350-4 1461350-5 1461350-6 1461350-7 9-1440003-7 9-1440003-8 9-1440003-9 1440004-0 1440004-1 1461410-2 1461352-2 1461352-3 1461352-4 1461352-5 1461352-6 1721767-2 1721767-3 1721767-4 1721767-5 1721767-6 1721767-7 1721766-2 1721766-3 1721766-4 1721766-5 1721766-6 1721766-7 1721768-2 1721768-3 1721768-4 1721768-5 1721768-6 3 Datasheet Rev. IJ1 Issued 2009/10 www.tycoelectronics.com www.schrackrelays.com Dimensions are in mm unless otherwise specified and are shown for reference purposes only. Product specification according to IEC 61810-1. Product data, technical parameters, test conditions and processing information only to be used together with the 'Definitions' section in the catalogue or at schrackrelays.com in the ‘Schrack’ section. Specifications subject to change.