MA-COM PCH

SCHRACK
General Purpose Relays
Miniature Power PCB Relay PCH
n
1pole 5 A, 1CO or 1NO contact
n
Sensitive 200 mW coil available
n
Version PCH-WG with tracking resistance PTI 250
on relay base and cover
n
WG version: Product in accordance to IEC60335-1
Applications
Domestic appliances, heating control, building control,
measurement & control
F_PCH_B
Approvals
PCH / PCH-WG:
V
119568
Z
E82292
Technical data of approved types on request
Contact data
PCH
Contact configuration
Contact set
Type of interruption
Rated voltage / max. switching voltage AC
Rated current
Limiting continuous current
Maximum breaking capacity AC
Contact material
Rated frequency of operation with / without load
Operate- / release time
Bounce time NO contact
Contact ratings
Type
Contact
IEC 61810
PCH-…2M-WG
PCH-…D2-WG
PCH-…D2M
PCH-…L2M
PCH-…D2
UL 508
PCH
PCH-WG
1 CO or 1 NO
single contact
micro-disconn.
250 / 400 VAC
5A
5 A, UL: 10 A
1250 VA
AgSnO2
6/600 min-1
max. 10/5 ms
max. 10 ms
Load
Ambient
temp. [°C]
Cycles
NO
NO of CO
NO
NO
CO
5 A, 250 VAC, cosϕ=1
5 A, 250 VAC, cosϕ=1
5 A, 250 VAC, cosϕ=1
5 A, 250 VAC, cosϕ=1
5 A/3 A, 250 VAC, cosϕ=1
85°C
85°C
70°C
70°C
40°C
100x103
100x103
100x103
30x103
30x103
NO
5 A, 250 VAC, general use
85°C
100x103
Coil data
standard
sensitiv
Rated coil voltage range DC coil
Operative range to IEC 61810
Coil insulation system according UL1446
5...48 VDC
5...24 VDC
1
class F
Coil versions, DC-coil - standard
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
05
5
3.75
0.5
62.5+10%
400
06
6
4.5
0.6
80+10%
400
09
9
6.3
0.9
202.5+10%
400
12
12
8.4
1.2
360+10%
400
24
24
16.8
2.4
1440+10%
400
48
48
33.6
4.8
5760+10%
400
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
1
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information only
to be used together with the
'Definitions' section in the catalogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
SCHRACK
General Purpose Relays
Miniature Power PCB Relay PCH (Continued)
Coil versions, DC-coil - sensitive
Coil
Rated
Operate
Release
Coil
Rated coil
code
voltage
voltage
voltage
resistance
power
VDC
VDC
VDC
Ohm
mW
05
5
3.75
0.5
125+10%
200
06
6
4.5
0.6
180+10%
200
09
9
6.75
0.9
400+10%
200
12
12
9.0
1.2
720+10%
200
24
24
18.0
2.4
2800+10%
200
All figures are given for coil without preenergization, at ambient temperature +23°C
Other coil voltages on request
PCB layout / terminal assignment
Bottom view on solder pins
Insulation
Dielectric strength coil-contact circuit
open contact circuit
Clearance / creepage coil-contact circuit
NO:
CO:
Material group of insulation parts
Tracking index of relay base, standard version
WG-version
Insulation to IEC 61810-1
Type of insulation coil-contact circuit
open contact circuit
Rated insulation voltage
Pollution degree
Rated voltage system
Overvoltage category
4000 Vrms
1000 Vrms
S0550-AA
5.5 / 9 mm
4.5 / 9 mm
IIIa
PTI 175
PTI 250
basic
micro disconnection
250 V
3
230 / 400 V
III
S0550-AB
Other data
Mechanical endurance, standard version
1.5x106 cycles
WG version
10x106 cycles
Material
RoHS - Directive 2002/95/EC
compliant as per product date code 0424
Resistance to heat and fire, WG-version
according EN60335, par.30
Environment
Ambient temperature range
all WG-versions:
-40...85°C
Standard NO:
-30...70°C
Standard CO:
-30...40°C
Vibration resistance (function) NO / NC contact >14 / 8 g, 30...400 Hz
Shock resistance (destruction)
100 g
Category of protection
RTII - flux proof
RTIII - wash tight
Processing
Mounting
PCB
Resistance to soldering heat flux-proof version
270°C / 10 s
wash-tight version
260°C / 5 s
Relay weight
7g
Packaging unit
25/1000 pcs
S0550-AC
Dimensions
S0551-B
2
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information only
to be used together with the
'Definitions' section in the catalogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.
SCHRACK
General Purpose Relays
Miniature Power PCB Relay PCH (Continued)
Product key
Typical product key
PCH
-1
12
D
2
Type
PCH
Miniature PCB Relay RE
Version
1
1 pole
Coil
05
5 VDC
06
6 VDC
09
9 VDC
Coil power
D
standard 400 mW
Contact material
2
AgSnO2
Contact configuration
Blank 1 CO contact (1 form C)
Enclosure
Blank flux proof
Version
Blank standard version
Other types on request
Product Key
PCH-105D2M
PCH-106D2M
PCH-109D2M
PCH-112D2M
PCH-124D2M
PCH-148D2M
PCH-105D2
PCH-106D2
PCH-109D2
PCH-112D2
PCH-124D2
PCH-148D2
PCH-105L2M
PCH-106L2M
PCH-109L2M
PCH-112L2M
PCH-124L2M
PCH-105D2M-WG
PCH-106D2M-WG
PCH-109D2M-WG
PCH-112D2M-WG
PCH-124D2M-WG
PCH-148D2M-WG
PCH-105D2-WG
PCH-106D2-WG
PCH-109D2-WG
PCH-112D2-WG
PCH-124D2-WG
PCH-148D2-WG
PCH-105L2M-WG
PCH-106L2M-WG
PCH-109L2M-WG
PCH-112L2M-WG
PCH-124L2M-WG
Version
flux proof
standard
12
24
48
12 VDC
24 VDC
48 VDC
L
sensitive 200 mW (for NO contact only)
M
1 NO contact (1 form A)
H
wash tight
WG
Product in accordance with IEC 60335-1 (domestic appliances)
Contact material
AgSnO2
Contacts
1 NO contact
1 CO contact
flux proof
sensitive
1 NO contact
flux proof
standard
materials according
IEC 60335-1
1 CO contact
flux proof
sensitive
materials according
IEC 60335-1
1 NO contact
Coil
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
48 VDC
5 VDC
6 VDC
9 VDC
12 VDC
24 VDC
Part number
1461350-2
1461350-3
1461350-4
1461350-5
1461350-6
1461350-7
9-1440003-7
9-1440003-8
9-1440003-9
1440004-0
1440004-1
1461410-2
1461352-2
1461352-3
1461352-4
1461352-5
1461352-6
1721767-2
1721767-3
1721767-4
1721767-5
1721767-6
1721767-7
1721766-2
1721766-3
1721766-4
1721766-5
1721766-6
1721766-7
1721768-2
1721768-3
1721768-4
1721768-5
1721768-6
3
Datasheet Rev. IJ1
Issued 2009/10
www.tycoelectronics.com
www.schrackrelays.com
Dimensions are in mm unless
otherwise specified and are
shown for reference purposes
only.
Product specification
according to IEC 61810-1.
Product data, technical parameters, test conditions and
processing information only
to be used together with the
'Definitions' section in the catalogue or at schrackrelays.com
in the ‘Schrack’ section.
Specifications subject to
change.