ETC 1021A

Innovations
Quality
Customer Satisfaction
PIEZOELECTRIC ACCELEROMETER
MODEL
1021A
• Miniature Design
• Ideal for High g Shock Measurements
• Frequency Response to 12 kHz
• Thru-Hole Bolt or Adhesive Mounting
• 360° Cable Orientation
• Replaceable Cable
Description
The VIP Sensors Model 1021A is a miniature piezoelectric
accelerometer designed for shock and vibration measurements
on small structures and objects. Its light weight minimizes or
eliminates any mass loading effects on the object being tested.
The accelerometer is a high-impedance, self-generating device
that requires no external power source for operation.
The Model 1021A incorporates a thru-hole mounting design
that allows for cable orientation in any direction. The unit is
sealed against external contamination. Signal ground is
connected to the outer case of the unit. The accelerometer
features a M3 connector that is used with low-noise coaxial
cable for connecting to signal conditioning electronics.
VIP Sensors Signal Conditioner Models 5002 and 5005 are
recommended for use with this high impedance accelerometer.
Typical Temperature Response
Typica l Amplitude Re sponse
10.00
5.00
0.00
-5.00
10
100
1000
10000
100000
FREQUENCY (HZ)
15
10
5
0
-5
-10
-15
% DEVIATION
% DEVIATION
15.00
1
Inch [mm]
-50
50
150
250
350
(-46)
(10)
(66)
(121)
(177)
TEMPERATURE °F (°C)
VIP Sensors
California, USA
Ph (949) 429 3558
Fx (949) 528 0126
[email protected]
www.vipsensors.com
VIP Sensors reserves the right to modify
these specifications without notice. V01
Innovations
Quality
Customer Satisfaction
PIEZOELECTRIC ACCELEROMETER
SPECIFICATIONS
The following performance specifications conform to ISA-RP-37.2 (1964) and are typical values, referenced at +75°F (+24°C) and
100 Hz, unless otherwise noted. Calibration data, traceable to National Institute of Standards and Technology (NIST), is supplied.
MODEL
1021A
UNITS
DYNAMIC CHARACTERISTICS
Axial Sensitivity
Transverse Sensitivity
Frequency Response
Resonance Frequency
Amplitude Response [1]
+5%
+ 1 dB
Temperature Response
Amplitude Linearity
pC/g
%
2 (1.7 minimum)
≤5
See Typical Amplitude Response
40,000
Hz
Hz
Hz
2 – 10,000
1 – 12,000
See Typical Temperature Response
<1
%
ELECTRICAL CHARACTERISTICS
Output Polarity
Resistance
Capacitance
Grounding
Acceleration directed from the base into
the transducer is defined as positive
>1
1,000
Signal ground connected to case
GΩ
pF
ENVIRONMENTAL CHARACTERISTICS
Temperature Range
°F (°C)
Humidity
Shock Limit
g pk
Base Strain
equiv. g pk/µ strain
Magnetic Field Sensitivity
equiv. g rms/gauss
(/T)
Thermal Transient Sensitivity
equiv. g pk/°F (/°C)
PHYSICAL CHARACTERISTICS
Weight
Case Material
Mounting
Piezoelectric Material
Structure
Output Connector
oz (grams)
-40 to +302 (-40 to +150)
Epoxy sealed
5,000
0.005
5E-6 (0.5)
0.05 (0.09)
0.05 (1.4)
Aluminum Alloy
Thru-hole screw, torque 2 N-m (18 lbf-in)
PZT-5
Annular Shear
M3 receptacle
ACCESSORIES
Included:
9009L10 Cable, Low Noise M3/10-32, 10ft (3.3 m)
Mounting Screw
Calibration Certificate
Optional:
9604
Cable Adapter 10-32/10-32
(extend cable length)
9006L10 Cable, Low Noise 10-32/10-32, 10 ft (3.3 m)
NOTES
1.
Low end response of the transducer is a function of
its electronics.
VIP Sensors
California, USA
Ph (949) 429 3558
Fx (949) 528 0126
[email protected]
www.vipsensors.com
VIP Sensors reserves the right to modify
these specifications without notice. V01