ADP4000 Product Preview Programmable Multi- Phase Synchronous Buck Converter with PMBus The ADP4000 is an integrated power control IC with a PMBus interface. The ADP4000 can be programmed for 1-, 2-, 3-, 4-, 5- or 6phase operation, allowing for the construction of up to six complementary buck switching stages. The ADP4000 supports PSI, which is a power state indicator and can be used to reduce number of operating phases at light loads. The ADP4000 includes a PMBus interface, which can be used to program system set points such as voltage offset, load line, phase balance and output voltage. Key system performance data such as CPU current, CPU voltage, and power and fault conditions can also be read back over the PMBus from the ADP4000. http://onsemi.com ADP4000 JCPZ #YYWW XXXXX CCCCC Features Typical Applications PIN ASSIGNMENT ALERT FAULT SDA SCL EN GND ADD / VSENSE2 VSENSE1 IMON TTSENSE VRHOT IREF 1 2 3 4 5 6 7 8 9 10 11 12 36 35 34 33 32 31 30 29 28 27 26 25 PIN 1 INDICATOR ADP4000 TOP VIEW (Not to Scale) PWM1 PWM2 PWM3 PWM4 PWM5 PWM6 SW1 SW2 SW3 SW4 SW5 SW6 RT 13 RAMPADJ 14 TRDET 15 FBRTN 16 COMP 17 FB 18 CSREF 19 CSSUM 20 CSCOMP 21 ILIMFS 22 ODN 23 OD1 24 • Servers • Desktop PC’s • POLs (Memory) = Device Code = Pb--Free Package = Date Code = Assembly Lot = Country of Origin VCC3 PWRGD PSI VID0 VID1 VID2 VID3 VID4 VID5 VID6 VID7 VCC PMBus Interface Supports Both VR11 and VR11.1 Specifications Digitally Programmable 0.375 V to 1.6 V Output Additional 200 mV Offset Programmable (Max 1.8 V Output) Selectable 1-, 2-, 3-, 4-, 5-, or 6-Phase Operation Fast-Enhanced PWM FlexModet TRDET to Improve Load Release Active Current Balancing Between All Output Phases Supports On--The--Fly (OTF) VID Code Changes Supports PSI – Power Saving Mode This is a Pb--Free Device xx # YYWW XXX CCC 48 47 46 45 44 43 42 41 40 39 38 37 • • • • • • • • • • • MARKING DIAGRAM LFCSP40 CASE 932AD ORDERING INFORMATION Device* Package Shipping† ADP4000JCPZ--REEL LFCSP48 2500/Tape & Reel ADP4000JCPZ--RL7 This document contains information on a product under development. ON Semiconductor reserves the right to change or discontinue this product without notice. © Semiconductor Components Industries, LLC, 2008 June, 2008 -- Rev. P0 1 LFCSP48 750/Tape & Reel *The “Z’ suffix indicates Pb--Free package. †For information on tape and reel specifications, including part orientation and tape sizes, please refer to our Tape and Reel Packaging Specifications Brochure, BRD8011/D. Publication Order Number: ADP4000/D ADP4000 ADD SCL 7 LIMIT REGISTERS ALERT 1 COMPARATOR SDA TRDET RT 4 3 RAMPADJ VCC VCC3 14 37 48 SHUNT REGULATOR 3.3 V REGULATOR 13 15 PMBUS 23 ODN 24 OD1 36 PWM1 RESET 35 PWM2 RESET 34 PWM3 33 PWM4 32 PWM5 31 PWM6 30 SW1 29 SW2 28 SW3 27 26 SW4 SW5 25 SW6 21 CSCOMP 19 CSREF 20 CSSUM 9 IMON 18 FB FAULT 2 STATUS REGISTERS UVLO SHUTDOWN 850 mV GND 6 OSCILLATOR DIGITAL CONFIG & VALUE CONTROL REGISTERS + + + CMP – MUX VSENSE1 8 ADC CURRENT BALANCING CIRCUIT VRHOT 11 + CMP – 2 / 3 / 4 /5 / 6 PHASE DRIVER LOGIC + THERMAL THROTTLING CONTROL TTSENSE 10 CMP CONTROL RESET – + RESET CMP – Over Voltage Threshold – CSREF + CMP + Under Voltage Threshold PWRGD 47 EN RESET CMP – – EN/VTT 5 SET RESET – CURRENT LIMIT CROWBAR + – DELAY CONTROL CURRENT MEASUREMENT AND LIMIT + – ILIMFS 22 CONTROL IREF 12 – COMP 17 + ADP4000 PSI 46 PRECISION REFERENCE 16 FBRTN CONTROL 44 43 42 41 40 VID0 VID1 VID2 VID3 VID4 VID5 39 38 VID6 VID7 Figure 1. Block Diagram http://onsemi.com 2 + – BOOT VOLTAGE& SOFT-- START CONTROL VID DAC 45 + – 100 k NTC 3 CSSUM RAMPADJ RT 220 k Figure 2. Application Schematic http://onsemi.com 470 pF X7R CSCOMP VID4 32.4 k VID5 1.21 k VID0 6.81 k, 1% 1000 pF SW6 SW5 SW4 SW3 SW2 SW1 35.7 k 1500 pF X7R 82.5 k 1k 1k 1k 1k 1k 1k 5% 100 k Thermistor 1500 pF X7R OD1 3.3 pF ILIMFS 560 pF ODN VID6 4.99 k VID7 69.8 k ADP4000 IREF VID1 121 k VRHOT TTSENSE IMON VSENSE1 PWM6 PWM5 PWM4 PWM3 PWM2 PWM1 1 uF X7R 680 470 pF X7R 0.1uF PROCHOT PWRGD ADD/VSENSE2 GND EN SCL PSI 20 k 4.54 k 1 nF Interface VID2 4.7 uF VTT I/O SDA FAULT VID3 1k 6.8 k PMBus VCC3 ALERT VCC FAULT 1200 uF 16 V 680 ALERT POWER GOOD PSI 1 uF X7R 1k Vin 12 V CSREF COMP FB FBRTN TRDET 348 k 4.7 uF 4.7 uF 4.7 uF 4.7 uF 4.7 uF 4.7 uF OD VCC 2 3 4 OD VCC 2 3 4 18 nF OD VCC 2 3 4 18 nF OD 2 3 18 nF DRVL 5 PGND 6 SW 7 DRVH 8 VCC 4 18 nF DRVL 5 PGND 6 SW 7 DRVH 8 OD 2 3 VCC BST IN 1 DRVL 5 PGND 6 SW 7 DRVH 8 ADP3121 10 nF 2.2 OD 2 3 BST IN 1 ADP3121 10 nF 2.2 VCC BST IN 1 10 nF DRVL 5 PGND 6 SW 7 DRVH 8 ADP3121 2.2 BST IN 1 10 nF DRVL 5 PGND 6 SW 7 DRVH 8 ADP3121 2.2 BST IN 1 4 18 nF DRVL 5 PGND 6 SW 7 DRVH 8 ADP3121 10 nF 2.2 BST IN 1 4 18 nF ADP3121 10 nF 2.2 150 nH 4.7 uF 150 nH 4.7 uF 150 nH 4.7 uF 150 nH 4.7 uF 150 nH 4.7 uF 150 nH 4.7 uF 10 10 10 10 10 10 Vcc Core (RTN) Vcc Core Vcc Sense Vss Sense ADP4000 63.4 k 63.4 k 63.4 k 63.4 k 63.4 k 63.4 k ADP4000 ABSOLUTE MAXIMUM RATINGS Rating Symbol Value Unit VIN --0.3 to 6 V VFBRTN --0.3 to + 0.3 V V --0.3 to VIN + 0.3 V SW1 to SW6 --5 to +25 V V SW1 to SW6 (<200 ns|) --10 to +25 V V --0.3 to VIN + 0.3 V --65 to 150 °C 0 to 85 °C Input Voltage Range (Note 1) FBRTN PWM2 to PWM6, Rampadj All other Inputs and Outputs Storage Temperature Range TSTG Operating Ambient Temperature Range ESD Capability, Human Body Model (Note 2) ESDHBM 2 kV ESD Capability, Machine Model (Note 2) ESDMM 100 V Moisture Sensitivity Level MSL 3 -- Lead Temperature Soldering Reflow (SMD Styles Only), Pb--Free Versions (Note 3) TSLD 260 °C Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect device reliability. 1. Refer to Electrical Characteristics and Application Information for Safe Operating Area. 2. This device series incorporates ESD protection and is tested by the following methods: ESD Human Body Model tested per AEC--Q100--002 (EIA/JESD22--A114) ESD Machine Model tested per AEC--Q100--003 (EIA/JESD22--A115) Latchup Current Maximum Rating: ≤150 mA per JEDEC standard: JESD78 3. For additional information on our Pb--Free strategy and soldering details, please download the ON Semiconductor Soldering and Mounting Techniques Reference Manual, SOLDERRM/D. THERMAL CHARACTERISTICS Characteristic Thermal Characteristics, LFCSP, 7 mm * 7 mm (Note 1) Thermal Resistance, Junction--to--Air (Note 4) Thermal Resistance, Junction--to--Lead 2 (Note 4) Symbol Value RθJA RΨJL 24 10 Unit °C/W 4. Values based on copper area of 645 mm2 (or 1 in2) of 1 oz copper thickness and FR4 PCB substrate. OPERATING RANGES (Note 1) Characteristic Output Voltage (Adjustable Version Only) (Note 5) Ambient Temperature 5. Maximum limit for VOUT = VOUT(NOM) -- 10%. http://onsemi.com 4 Symbol Min Max Unit VOUT 0.375 1.8 V TA 0 85 °C ADP4000 PIN ASSIGNMENT Pin No. Pin Name 1 ALERT ALERT Output. Open drain output that asserts low when the VR exceeds a programmable limit. Description 2 FAULT FAULT Output. Open drain output that asserts low when a fault has occurred. This fault can be due to VR or current--limit, crowbar, or undervoltage. The trip points are loaded into registers. 3 SDA Digital Input Output. PMBus serial data bi--directional pin. Requires PMBus pullup. 4 SCL Digital Input. PMBus serial bus clock open drain input. Requires PMBus pullup. 5 EN Power Supply Enable Input. Pulling this pin to GND disables the PWM outputs and pulls the PWRGD output low. 6 GND 7 ADD/ VSENSE2 PMBus Address Input. Connect a resistor to ground to select one of 8 addresses. This input is reconfigured after startup as an analog voltage monitor, VSENSE2. 8 VSENSE1 Analog Input. Measures an input voltage between 0 and 2.0 V and reports this back over the PMBus interface. Ground. All internal biasing and the logic output signals of the device are referenced to this ground. 9 IMON 10 TTSENSE VR Temperature Sense Input. An NTC thermistor between this pin and GND is used to remotely sense the temperature at the desired thermal monitoring point. 11 VRHOT VR HOT Output. Open drain output that signals when the temperature at the monitoring point connected to TTSENSE exceeds the VRHOT temperature threshold. 12 IREF 13 RT 14 RAMPADJ 15 TRDET Transient Detect. This output is asserted low whenever a load release is detected 16 FBRTN Feedback Return. VID DAC and error amplifier reference for remote sensing of the output voltage. 17 COMP Error Amplifier Output and Compensation Point. 18 FB 19 CSREF Current Sense Reference Voltage Input. The voltage on this pin is used as the reference for the current sense amplifier and the Power--Good and crowbar functions. This pin should be connected to the common point of the output inductors. 20 CSSUM Current Sense Summing Node. External resistors from each switch node to this pin sum the average inductor currents together to measure the total output current. 21 CSCOMP Current Sense Compensation Point. A resistor and capacitor from this pin to CSSUM determines the gain of the current sense amplifier and the positioning loop response time. 22 ILIMFS Current Sense and Limit Scaling Pin. An external resistor from this pin to CSCOMP sets the internal current sensing signal for current--limit and IMON. This value can be over--written using PMBus interface. 23 ODN Output Disable Logic Output for PSI operation. This pin is actively pulled low when PSI is low, otherwise it functions in the same way as OD1. 24 OD1 Output Disable Logic Output. This pin is actively pulled low when the EN input is low or when VCC is below its UVLO threshold to signal to the Driver IC that the driver high--side and low--side outputs should go low. 25 to 30 SW6 to SW1 Current Balance Inputs. Inputs for measuring the current level in each phase. The SW pins of unused phases should be left open. 31 to 36 PWM6 to PWM1 Logic--Level PWM Outputs. Each output is connected to the input of an external MOSFET driver such as the ADP3121. Connecting PWM6 to VCC disables PWM6, connecting PWM5 to VCC disables PWM5 and PWM6, etc. This means the ADP4000 can be setup to operate as a 1-- 2--, 3--, 4--, 5--, or 6--phase controller. 37 VCC Supply Voltage for the Device. A 340 Ω resistor should be placed between the 12 V system supply and the VCC pin. The internal shunt regulator maintains VCC = 5.0 V. 38 to 45 VID7 to VID0 Voltage Identification DAC Inputs. These eight pins are pulled down to GND, providing a logic zero if left open. When in normal operation mode, the DAC output programs the FB regulation voltage from 0.375 V to 1.6 V. 46 PSI 47 PWRGD 48 VCC3 Total Current Output Pin. Current Reference Input. An external resistor from this pin to ground sets the reference current for IFB, IILIMFS, and ITH(X). Frequency Setting Resistor Input. An external resistor connected between this pin and GND sets the oscillator frequency of the device. PWM Ramp Current Input. An external resistor from the converter input voltage to this pin sets the internal PWM ramp. Feedback Input. Error amplifier input for remote sensing of the output voltage. An external resistor between this pin and the output voltage sets the no load offset point. Power State Indicator. Pulling this pin low places the controller in lower power state operation. Power--Good Output. Open--drain output that signals when the output voltage is outside of the proper operating range. 3.3 V Power Supply Output. A capacitor from this pin to ground provided decoupling for the interval 3.3 V LDO. http://onsemi.com 5 ADP4000 ELECTRICAL CHARACTERISTICS VIN = (5.0 V) FBRTN -- GND, for typical values TA = 25°C, for min/max values TA = 0°C to 85°C; unless otherwise noted. (Notes 6 and 7) Test Conditions Parameter Symbol Min Typ Max Unit VIREF 1.75 1.8 1.85 V Reference Current Reference Bias Voltage Reference Bias Current IIREF RIREF = 121 kΩ 15 mA Error Amplifier VCOMP 0 4.4 V VFB --7 +7 mV VFB(BOOT) 1.093 1.1 1.107 V Load Line Positioning Accuracy --77 --80 --83 mV Load Line Range --350 0 mV Output Voltage Range Accuracy Relative to nominal DAC output, referenced to FBRTN (see Figure 2) In startup Load Line Attenuation Differential Non--linearity Input Bias Current Offset Accuracy IFB 0 100 % --1.0 +1.0 LSB 14.2 VR Offset Register = 111111, VID = 1.0 V VR Offset Register = 011111, VID = 1.0 V FBRTN Current Output Current FB forced to VOUT --3% Gain Bandwidth Product COMP = FB Slew Rate COMP = FB BOOT Voltage Hold Time Internal Timer 16 17.7 --193.75 193.75 mA mV IFBRTN 100 200 ICOMP 500 mA GBW(ERR) 20 MHz 25 V/ms tBOOT 2.0 ms mA VID Inputs Input Low Voltage VID(X) VIL(VID) Input High Voltage VID(X) VIH(VID) Input Current 0.3 0.8 IIN(VID) V V --5.0 mA VID Transition Delay Time VID code change to FB change 200 ns No CPU Detection Turn--Off Delay Time VID code change to PWM going low 5.0 ms Oscillator Frequency Range Frequency Variation TA = 25°C, RT = 270 kΩ, 6--phase TA = 25°C, RT = 130 kΩ, 6--phase TA = 25°C, RT = 68 kΩ, 6--phase Output Voltage RT = 500 kΩ to GND RAMPADJ Output Voltage RAMPADJ -- FB, VFB = 1.0 V, IRAMPADJ = --150 mA RAMPADJ Input Current Range fOSC 0.25 9.0 MHz fPHASE 225 245 500 850 265 kHz VRT 1.93 2.03 2.13 V VRAMPADJ --50 +50 mV IRAMPADJ 5.0 60 mA VOS(CSA) --1.0 +1.0 mV Current Sense Amplifier Offset Voltage CSSUM -- CSREF (see Figure 4) Input Bias Current, CSREF CSREF = 1.0 V IBIAS(CSREF) --20 +20 mA Input Bias Current, CSSUM CSREF = 1.0 V IBIAS(CSSUM) --10 +10 nA Gain Bandwidth Product CSSUM = CSCOMP GBW(CSA) 10 MHz Current Sense Amplifier Slew Rate CCSCOMP = 10 pF Input Common--Mode Range CSSUM and CSREF 10 Output Voltage Range Output Current Current--Limit Latchoff Delay Time ICSCOMP Internal Timer 6. Refer to Absolute Maximum Ratings and Application Information for Safe Operating Area. 7. Guaranteed by design, not production tested. http://onsemi.com 6 V/ms 0 3.0 V 0.05 3.0 V 500 mA 8.0 ms ADP4000 ELECTRICAL CHARACTERISTICS VIN = (5.0 V) FBRTN -- GND, for typical values TA = 25°C, for min/max values TA = 0°C to 85°C; unless otherwise noted. (Notes 6 and 7) Parameter Test Conditions Symbol Min Typ Max Unit 0.3 V PSI Input Low Voltage Input High Voltage 0.8 Input Current V --5 mA Assertion Timing Fsw = 300kHz 3.3 ms Deassertion Timing Fsw = 300kHz 825 ns TRDET Output Low Voltage IOUT = --6 mA VOL 150 300 mV IMON Clamp Voltage Accuracy 10 x (CSREF -- CSCOMP)/RILIM 1.0 1.15 V --3.0 3.0 % Output Current Offset --5.5 800 mA 5.5 mV Current--Limit Comparator ILIM Bias Current CSREF -- CSCOMP)/RILIM, (CSREF -- CSCOMP) = 150 mV, RILIM = 7.5 kΩ ILIM 22 mA Current--Limit Threshold Current 4/3 x IIREF ICL 22 mA Current Balance Amplifier VSW(X)CM --600 +200 mV Input Resistance SW(X) = 0 V RSW(X) 12 18 21 kΩ Input Current SW(X) = 0 V ISW(X) 8.0 12 18 mA Input Current Matching SW(X) = 0 V ΔISW(X) --6.0 +6.0 % Phase Balance Adjustment Range Low Phase Bal Registers = 00000 --25 % Phase Balance Adjustment Range High Phase Bal Registers = 11111 +25 % Internal Timer Delay Time Register = 011 2.0 ms Timer Range Low Delay Time Register = 000 0.5 ms Timer Range High Delay Time Register = 111 4.0 ms Common--Mode Range Delay Timer Soft--Start Internal Timer Soft--Start Slope Register = 010 0.5 V/ms Timer Range Low Soft--Start Slope Register = 000 0.1 V/ms Timer Range High Soft--Start Slope Register = 111 1.5 V/ms Enable Input Input Low Voltage VIL(EN) Input High Voltage VIH(EN) Input Current 0.3 0.8 V V IIN(EN) --1.0 mA EN > 0.8 V, Internal Delay tDELAY(EN) 2.0 ms Output Low Voltage IOD(SINK) = --400 mA VOL(ODN/1) Output High Voltage IOD(SOURCE) = 400 mA VOL(ODN/1) Delay Time ODN and OD1 Outputs ODN / OD1 Pulldown Resistor 6. Refer to Absolute Maximum Ratings and Application Information for Safe Operating Area. 7. Guaranteed by design, not production tested. http://onsemi.com 7 160 4.0 500 mV 5.0 V 60 kΩ ADP4000 ELECTRICAL CHARACTERISTICS VIN = (5.0 V) FBRTN -- GND, for typical values TA = 25°C, for min/max values TA = 0°C to 85°C; unless otherwise noted. (Notes 6 and 7) Parameter Test Conditions Symbol Min Typ Max Unit VPWRGD(UV) --600 --500 --400 mV Power--Good Comparator Undervoltage Threshold Relative to Nominal DAC Output Undervoltage Adjustment Range Low PWRGD_LO Register = 000 --500 mV Undervoltage Adjustment Range High PWRGD_LO Register = 111 --150 mV Overvoltage Threshold Relative to DAC Output, PWRGD_Hi = 00 Overvoltage Adjustment Range Low PWRGD_Hi Register = 11 Overvoltage Adjustment Range High PWRGD_Hi Register = 00 Output Low Voltage IPWRGD(SINK) = --4 mA VPWRGD(OV) 200 300 400 150 mV 300 VOL(PWRGD) 150 mV mV 300 mV Power Good Delay Time During Soft--Start Internal Timer VID Code Changing 100 VID Code Static 2.0 ms 250 ms 200 VCROWBAR 200 300 ns Crowbar Trip Point Relative to DAC Output, PWRGD_Hi = 00 400 mV Crowbar Adjustment Range PWRGD_Hi Register 150 Crowbar Reset Point Relative to FBRTN 250 300 300 mV 350 Crowbar Delay Time Overvoltage to PWM going low mV 100 250 ms 400 ns tCROWBAR VID Code Changing VID Code Static PWM Outputs Output Low Voltage IPWM(SINK) = --400 mA VOL(PWM) 160 Output High Voltage IPWM(SOURCE) = 400 mA VOH(PWM) 4.0 Logic High Input Voltage VIH(SDA,SCL) 2.1 Logic Low Input Voltage VIH(SDA,SCL) 500 5.0 mV V PMBus Interface 0.8 Hysteresis SDA Output Low Voltage V 500 ISDA = --6 mA VOL Input Current VIH; IIL Input Capacitance CSCL, SDA Clock Frequency fSCL --1 0.4 V 1.0 mA 400 kHz 1.0 ms 5.0 SCL Falling Edge to SDA Valid Time V mV pF ALERT, FAULT Outputs Output Low Voltage IOUT = --6 mA VOL 0.4 V Output High Leakage Current VOH = 5.0 V VOH 1.0 mA 3.0 V TTSENSE Inputs TTSENSE Voltage Range Internally Limited 0 Source Current RIREF = 121 kΩ VRHOT Output Low Voltage IVRHOT(SINK) = --4mA ITH Input Voltage Conversion Range ADC Resolution --110 --125 --140 mA 150 300 mV 0 LSB Weighting 2.0 2.0 V mV Analog / Digital Converter 0 ADC Input Voltage Range ADC Resolution Total Unadjusted Error (TUE) Differential Non--linearity (DNL) 2.0 1.95 8 Bits 6. Refer to Absolute Maximum Ratings and Application Information for Safe Operating Area. 7. Guaranteed by design, not production tested. http://onsemi.com 8 V mV 1.0 % 1.0 LSB ADP4000 ELECTRICAL CHARACTERISTICS VIN = (5.0 V) FBRTN -- GND, for typical values TA = 25°C, for min/max values TA = 0°C to 85°C; unless otherwise noted. (Notes 6 and 7) Parameter Test Conditions Symbol Min Typ Max Unit Analog / Digital Converter cont. Conversion Time, Voltage Channel Averaging Enabled (32 averages) Round Robin Cycle Time 80 ms TBD ms ADD Input IADD = 2/3*IIREF ADD Output Current IADD 10 Address 000 Threshold mA 0.1 V Address 001 Threshold 0.15 0.225 V Address 010 Threshold 0.3 0.45 V Address 011 Threshold 0.5 0.675 V Address 100 Threshold 0.75 0.9 V Address 101 Threshold 1.0 1.25 V Address 110 Threshold 1.35 1.7 V Address 111 Threshold 1.8 V Supply VCC VCC DC Supply Current (see Figure 2) VSYSTEM = 13.2 V, RSHUNT = 340 Ω 4.7 IVCC UVLO Turn--On Current UVLO Threshold Voltage VCC Rising UVLO Turn--Off Voltage VCC Falling VCC3 Output Voltage IVCC3 = 1 mA VUVLO 9.5 VCC3 3.0 5.25 5.75 V 20 25 mA 6.5 11 mA V 4.1 3.3 6. Refer to Absolute Maximum Ratings and Application Information for Safe Operating Area. 7. Guaranteed by design, not production tested. TYPICAL CHARACTERISTICS 3000 2500 Frequency (Hz) 2000 PWM1 1500 1000 500 0 13 20 30 43 50 68 75 82 130 180 270 395 430 500 680 850 RT (kΩ) Figure 3. ADP4000 RT vs Frequency http://onsemi.com 9 V 3.6 V ADP4000 TEST CIRCUITS +12 V +1.25 V 680 Ω +1 m F 100 nF PWM1 PWM2 NC PWM3 NC PWM4 EN PWM5 ADP4000 GND PSI_SET PWM6 SW1 1 kΩ 20 k Ω SW4 SW5 SW6 ODN OD1 CSSUM CSCOMP ILIMITFS RT IREF SW2 SW3 COMP FB CSREF VRHOT RAMPADJ TRDET FBRTN LLSET IMON TTSENSE 121 kΩ 680 Ω VID6 VID7 VCC VID3 VID4 VID5 VID1 VID2 VCC3 NC NC PWRGD PSI VID0 8 BIT VID CODE 10 kΩ 100 nF Figure 4. Closed-Loop Output Voltage Accuracy ADP4000 12 V 12 V 680 Ω ADP4000 680 Ω 680 Ω VCC 37 1 kΩ VCC 37 COMP 17 10 k Ω CSCOMP 21 39 k Ω 680 Ω FB 18 100 nF CSSUM 20 – CSREF 19 CSREF 19 + 1V GND 6 VOS = 1V CSCOMP – 1 V 40 6 VID DAC GND ΔVFB= FBΔV = 80mV – FBΔV = 0 mV Figure 6. Positioning Voltage Figure 5. Current Sense Amplifier VOS http://onsemi.com 10 ADP4000 Description current--limit latchoff as explained in the Current--Limit section. The current--limit timer is set to 4 times the delay timer. The ADP4000 is a 6--Phase VR11.1 regulator with a PMBus Interface Typical application circuits is shown in Figure 2. Table 1. Delay Codes Startup Sequence The ADP4000 follows the VR11 start-up sequence shown in Figure 7. After both the EN and UVLO conditions are met, a programmable internal timer goes through one delay cycle TD1. This delay cycle is programmed using Delay Command, default delay = 2 ms, see Table 1 for programmable values). The first six clock cycles of TD2 are blanked from the PWM outputs and used for phase detection as explained in the following section. Then the programmable internal soft--start ramp is enabled (TD2) and the output comes up to the boot voltage of 1.1V. The boot hold time is also set by Delay Command. This second delay cycle is called TD3. During TD3 the processor VID pins settle to the required VID code. When TD3 is over, the ADP4000 reads the VID inputs and soft--starts either up or down to the final VID voltage (TD4). After TD4 has been completed and the PWRGD masking time (equal to VID on the fly masking) is finished, a third cycle of the internal timer sets the PWRGD blanking (TD5). The internal delay and soft--start times are programmable using the serial interface and the Delay Command and the Soft--Start Commands. 5.0 V SUPPLY VTT I/O (ADP4000 EN) VCC_CORE TD1 VVID TD4 VR READY (ADP4000 PWRGD) CPU VID INPUTS VID INVALID 1 010 1.5 011 2 = default 100 2.5 101 3 110 3.5 111 4 The soft--start slope for the output voltage is set by an internal timer. The default value is 0.5 V/msec, which can be programmed through the PMBus interface. After TD1 and the phase detection cycle have been completed, the SS time (TD2 in Figure 7) starts. The SS circuit uses the internal VID DAC to increase the output voltage in 6.25 mV steps up to the 1.1 V boot voltage. Once the SS circuit has reached the boot voltage, the boot voltage delay time (TD3) is started. The end of the boot voltage delay time signals the beginning of the second soft--start time (TD4). The SS voltage changes from the boot voltage to the programmed VID DAC voltage (either higher or lower) using 6.25 mV steps. The soft--start slew rate is programmed using Bits <2:0> of the Ton_Rise (0xD5) command code. Table 2 provides the soft--start values TD2 50 ms 0.5 001 Soft--Start TD3 VBOOT (1.1 V) Delay (msec) 000 The delay timer is programmed using Bits <2:0> of the Ton Delay command (0xD4). The delay can be programmed between 0.5 msec and 4 msec. Table 1 provides the programmable delay times. UVLO THRESHOLD 0.85 V Code TD5 Table 2. Slew Rate Codes VID VALID Figure 7. System Startup Sequence for VR11 Internal Delay Timer An internal timer sets the delay times for the startup sequence, TD1, TD3 and TD5. The default time is 2msec, which can be changed using the PMBus interface. This timer is used for multiple delay timings (TD1, TD3 and TD5) during the startup sequence. Also, it is used for timing the http://onsemi.com 11 Code Slew Rate (V/msec) 000 0.1 001 0.3 010 0.5 = default 011 0.7 100 0.9 101 1.1 110 1.3 111 1.5 ADP4000 Master Clock Frequency The clock frequency of the ADP4000 is set with an external resistor connected from the RT pin to ground. The frequency follows the graph in Figure 3. To determine the frequency per phase, the clock is divided by the number of phases in use. If all phases are in use, divide by 6. If 4 phases are in use then divide by 4. RT = 1 − R TO n × f SW × Cr (eq. 1) where CT = 2.2 pF and RTO = 21 k Output Voltage Differential Sensing The ADP4000 combines differential sensing with a high accuracy VID DAC and reference, and a low offset error amplifier. This maintains a worst-case specification of ±7 mV differential sensing error over its full operating output voltage and temperature range. The output voltage is sensed between the FB pin and FBRTN pin. FB is connected through a resistor, RB, to the regulation point, usually the remote sense pin of the microprocessor. FBRTN is connected directly to the remote sense ground point. The internal VID DAC and precision reference are referenced to FBRTN, which has a minimal current of 100 mA to allow accurate remote sensing. The internal error amplifier compares the output of the DAC to the FB pin to regulate the output voltage. Figure 8. System Startup Sequence for VR11 Figure 8 shows typical startup waveforms for the ADP4000. Figure 8. Typical Start-up Waveforms Channel 1: CSREF (yellow) Channel 2: PWM1 (blue) Channel 3 : Enable (pink) Phase Detection During startup, the number of operational phases and their phase relationship is determined by the internal circuitry that monitors the PWM outputs. Normally, the ADP4000 operates as a 6--phase PWM controller. Output Current Sensing The ADP4000 provides a dedicated current--sense amplifier (CSA) to monitor the total output current for proper voltage positioning vs. load current, for the IMON output and for current-limit detection. Sensing the load current at the output gives the total real time current being delivered to the load, which is an inherently more accurate method than peak current detection or sampling the current across a sense element such as the low-side MOSFET. This amplifier can be configured several ways, depending on the objectives of the system, as follows: • Output inductor DCR sensing without a thermistor for lowest cost. • Output inductor DCR sensing with a thermistor for improved accuracy with tracking of inductor temperature. • Sense resistors for highest accuracy measurements. The positive input of the CSA is connected to the CSREF pin, which is connected to the average output voltage. The inputs to the amplifier are summed together through resistors from the sensing element, such as the switch node side of the output inductors, to the inverting input CSSUM. The feedback resistor between CSCOMP and CSSUM sets the gain of the amplifier and a filter capacitor is placed in parallel with this resistor. The gain of the amplifier is programmable by adjusting the feedback resistor. This difference signal is used internally to offset the VID DAC for voltage positioning. This difference signal can be adjusted between 50% and 150% of the external value To operate as a 5--Phase Controller connect PWM6 to VCC. To operate as a 4--Phase Controller connect PWM5 and PWM6 to VCC. To operate as a 3--Phase Controller connect PWM4, PWM5 and PWM6 to VCC. To operate as a 2--Phase Controller connect PWM3, PWM4, PWM5 and PWM6 to VCC. To operate as a single--phase controller connect PMW2, PWM3, PWM4, PWM5 and PWM6 to VCC. Prior to soft--start, while EN is high the PWM6, PWM5, PWM4 PWM3 and PWM2 pins sink approximately 100 mA each. An internal comparator checks each pin’s voltage vs. a threshold of 3.0 V. If the pin is tied to VCC, it is above the threshold. Otherwise, an internal current sink pulls the pin to GND, which is below the threshold. PWM1 is low during the phase detection interval that occurs during the first six clock cycles of TD2. After this time, if the remaining PWM outputs are not pulled to VCC, the 100 mA current sink is removed, and they function as normal PWM outputs. If they are pulled to VCC, the 100 mA current source is removed, and the outputs are put into a high impedance state. The PWM outputs are logic-level devices intended for driving fast response external gate drivers such as the ADP3121. Because each phase is monitored independently, operation approaching 100% duty cycle is possible. In addition, more than one output can be on at the same time to allow overlapping phases. http://onsemi.com 12 ADP4000 Table 3. Current--Limit using the PMBus Loadline Calibration (0xDE) and Loadline Set (0xDF) commands. The difference between CSREF and CSCOMP is used as a differential input for the current-limit comparator. To provide the best accuracy for sensing current, the CSA is designed to have a low offset input voltage. Also, the sensing gain is determined by external resistors to make it extremely accurate. The CPU current can also be monitored over the PMBus. The current--limit and the load line can be adjusted from the circuit component values over the PMBus. Code Where VILIMFS = VCSREF V CSREF − V CSCOMP = R CS × R L × I LOAD R PH (eq. 2) (eq. 3) Where RL = DCR of the Inductor. Assuming that R CS × R L = 1 mΩ R PH (eq. 4) i.e. the external circuit is set up for a 1mΩ Loadline then the RILIMFS is calculated as follows I ILIMFS = 1 mΩ × I LOAD R ILIMITFS 53.3% 1 0000 100% = default 1 0001 103.3% 1 1110 143.3% 1 1111 146.7% If the current--limit is reached and TD5 has completed, an internal latch-off delay time will start, and the controller will shut down if the fault is not removed. This delay is four times longer than the delay time during the startup sequence. The current--limit delay time only starts after the TD5 has completed. If there is a current--limit during start-up, the ADP4000 will go through TD1 to TD5, and then start the latchoff time. Because the controller continues to cycle the phases during the latchoff delay time, if the short is removed before the timer is complete, the controller can return to normal operation. The latchoff function can be reset by either removing and reapplying the supply voltage to the ADP4000, or by toggling the EN pin low for a short time. During startup when the output voltage is below 200 mV, a secondary current--limit is active. This is necessary because the voltage swing of CSCOMP cannot go below ground. This secondary current--limit limits the internal COMP voltage to the PWM comparators to 1.5 V. This limits the voltage drop across the low-side MOSFETs through the current balance circuitry. Typical over-current latchoff waveforms are shown in Figure 9. The current--limit threshold on the ADP4000 is programmed by a resistor between the ILIMFS pin and the CSCOMP pin. The ILIMFS current, IILIMFS, is compared with an internal current reference of 22 mA. If IILIMFS exceeds 22 mA then the output current has exceeded the limit and the current--limit protection is tripped. V ILIMFS − V CSCOMP R ILIMFS 50% 0 0001 Current--Limit, Short Circuit and latchoff protection Current--Limit Setpoint I ILIMFS = Current--Limit (% of external limit) 0 0000 (eq. 5) Assuming we want a current--limit of 150A that means that ILIMFS must equal 22 mA at that load. 20 mA = 1 mΩ × 150 AD = 6.8 kΩ R ILIMITFS (eq. 6) Solving this equation for RLIMITFS we get 6.8 kΩ. The closest 1% resistor value is 6.8 kΩ. The current--limit threshold can be modified from the resistor programmed value by using the PMBus interface using Bits <4:0> of the Current--Limit Threshold command (0xE2). The limit is programmable between 50% of the external limit and 146.7% of the external limit. The resolution is 3.3%. Table 3 gives some examples codes. Figure 9. Overcurrent Latchoff Waveforms Channel 1: CSREF, Channel 2: COMP, Channel 3: PWM1 http://onsemi.com 13 ADP4000 Load Line Setting An inherent per phase current--limit protects individual phases if one or more phases stops functioning because of a faulty component. This limit is based on the maximum normal mode COMP voltage. The Loadline is programmable over the PMBus on the ADP4000. It is programmed using the Loadline Calibration (0xDE) and Loadline Set (0xDF) commands. The loadline can be adjusted between 0% and 100% of the external RCSA. In this example RCSA = 1 mΩ. RO needs to 0.8 mΩ. Therefore programming the Loadline Calibration + Loadline Set Register to give a combined percentage of 80% will set the RO to 0.8 mΩ. Output Current Monitor IMON is an analog output from the ADP4000 representing the total current being delivered to the load. It outputs an accurate current that is directly proportional to the current set by the ILIMFS resistor. I IMON = 10 × I ILIMFS Table 4. Loadline Commands (eq. 7) Code The current is then run through a parallel RC connected from the IMON pin to the FBRTN pin to generate an accurately scaled and filtered voltage as per the VR11.1 specification. The size of the resistor is used to set the IMON scaling. The scaling is set such that IMON = 900mV at the TDC current of the processor. This means that the RIMON resistor should be chosen as follows. From the Current--Limit Setpoint paragraph we know the following: I ILIMFS = 1 mΩ × I LOAD R ILIMFS I IMON = 10 × 1 mΩ × ILOAD R ILIMFS V IMON = 900 mV = 198 mA × R MON 3.3% 1 0000 50% = default 1 0001 53.3% 1 1110 96.7% 1 1111 100% The ADP4000 has individual inputs (SW1 to SW6) for each phase that are used for monitoring the current of each phase. This information is combined with an internal ramp to create a current balancing feedback system that has been optimized for initial current balance accuracy and dynamic thermal balancing during operation. This current balance information is independent of the average output current information used for positioning as described in the section. The magnitude of the internal ramp can be set to optimize the transient response of the system. It also monitors the supply voltage for feed-forward control for changes in the supply. A resistor connected from the power input voltage to the RAMPADJ pin determines the slope of the internal PWM ramp. The balance between the phases can be programmed using the PMBus Phase Bal SW(x) commands (0xE3 to 0xE8). This allows each phase to be adjusted if there is a difference in temperature due to layout and airflow considerations. The phase balance can be adjusted from a default gain of 5 (Bits 4:0 = 10000). The minimum gain programmable is 3.75 (Bits 4:0 = 00000) and the max gain is 6.25 (Bits 4:0 = 11111). (eq. 8) (eq. 9) When ILOAD = 135A, IMON equals 1 mΩ × 135 A = 198 mA 6.81 kΩ 0% 0 0001 Current Control Mode and Thermal Balance For a 150 A current--limit RLIMFS = 7.5 kΩ. Assuming the TDC = 135 A then VMON should equal 900 mV when ILOAD = 135 A. I IMON = 10 × Loadline (as a percentage of RCSA) 0 0000 (eq. 10) (eq. 11) This gives a value of 4.54 kΩ for RMON. If the TDC and OCP limit for the processor have to be changed then it may be necessary to change the ILIMITFS resistor only. This is because the ILIMITFS resistor sets up both the current--limit and also the current out of the IMON pin, as explained earlier. The IMON pin also includes an active clamp to limit the IMON voltage to 1.15 V MAX while maintaining accuracy at 900 mV full scale. Voltage Control Mode A high gain, high bandwidth, voltage mode error amplifier is used for the voltage mode control loop. The control input voltage to the positive input is set via the VID logic according to the voltages listed in VID Code Table. The VID code is set using the VID Input pins or it can be programmed over the PMBus using the VOUT_Command. By default, the ADP4000 outputs a voltage corresponding to the VID Inputs. To output a voltage following the VOUT_Command the user first needs to program the required VID Code. Then the VID_EN Bits need to be enabled. The following is the sequence: Active Impedance Control Mode For controlling the dynamic output voltage droop as a function of output current, the CSA gain and load line programming can be scaled to be equal to the droop impedance of the regulator times the output current. This droop voltage is then used to set the input control voltage to the system. The droop voltage is subtracted from the DAC reference input voltage directly to tell the error amplifier where the output voltage should be. This allows enhanced feed-forward response. http://onsemi.com 14 ADP4000 1. Program the required VID Code to the VOUT_Command code (0x21) 2. Set the VID_EN bit (Bit 3) in the VR Config 1 A (0xD2) and on the VR Config 1B (0xD3). This voltage is also offset by the droop voltage for active positioning of the output voltage as a function of current, commonly known as active voltage positioning. The output of the amplifier is the COMP pin, which sets the termination voltage for the internal PWM ramps. The negative input (FB) is tied to the output sense location with Resistor RB and is used for sensing and controlling the output voltage at this point. A current source (equal to IFB) from the FB pin flowing through RB is used for setting the no load offset voltage from the VID voltage. The no load voltage is negative with respect to the VID DAC for Intel CPU’s. The value of RB can be found using the following equation. RB = V VID − V ONL I IFB The size of the internal ramp can be made larger or smaller. If it is made larger, stability and noise rejection improves but the transient performance decreases. If the ramp is made smaller then the transient response improves however noise rejection and stability degrades. COMP Pin Ramp There is a ramp signal on the COMP signal, which is due to the droop voltage and the output voltage ramps. This ramp adds to the internal ramp to produce the following ramp signal at the PWM input. V RT = 1− An offset voltage can be added to the control voltage over the serial interface. This is done using Bits <5:0> of the VOUT_TRIM (0xDB) and VOUT_CAL (0xDC) Commands. The max offset that can be applied is ±193.75 mV (even if the sum of the offsets > 193.75mV). The LSB size is 6.25 mV. A positive offset is applied when Bit 5 = 0. A negative offset is applied when Bit 5 = 1. VOUT_ CAL CODE CAL OFFSET VOLTAGE TOTAL OFFSET VOLTAGE 00 1000 50 mV 00 0010 12.5 mV 62.5 mV 10 0001 -6.25 mV 10 1110 -87.5 mV -93.75 mV 00 1111 93.75 mV 10 0001 -6.25 mV 87.5 mV The ADP4000 has the ability to respond to dynamically changing VID inputs while the controller is running. This allows the output voltage to change while the supply is running and supplying current to the load. This is commonly referred to as Dynamic VID (DVID). A DVID can occur under either light or heavy load conditions. The processor signals the controller by changing the VID inputs (or by programming a new VOUT_Command) in a single or multiple steps from the start code to the finish code. This change can be positive or negative. When a VID bit changes state, the ADP4000 detects the change and ignores the DAC inputs for a minimum of 200 ns. This time prevents a false code due to logic skew while the VID inputs are changing. Additionally, the first VID change initiates the PWRGD and CROWBAR blanking functions for a minimum of 100 ms to prevent a false PWRGD or CROWBAR event. Each VID change resets the internal timer. If a VID off code is detected the ADP4000 will wait for 5 msec to ensure that the code is correct before initiating a shutdown of the controller. The ADP4000 also uses the TON_Transition command code (0xD6) to limit the DVID slew rates. These can be encountered when the system does a large single VID step for power state changes, thus the DVID slew rate needs to be limited to prevent large inrush currents. RAMPADJ Input Current The resistor connected to the Rampadj pin sets the internal PWM ramp. The value for this resistor is chosen to provide the combination of thermal balance, stability and transient response. RR = AR × L 3 × A D × R DS × C R (eq. 13) Where AR is the internal ramp amplifier gain (= 0.5) AD is the current balancing amplifier gain (= 5) RDS is the total low side MOSFET on resistance CR is the internal ramp capacitor value (= 5pF). The internal ramp voltage can be calculated as follows: VR = A R × (1 − D) × V VID R R × C R × fSW (eq. 15) Dynamic VID Table 5. Offset Codes TRIM OFFSET VOLTAGE 2×(1−n×D) n×f SW×C X×R O Where Cx = bulk capacitance RO = Droop n = number of phases fSW = switching frequency per phase D = duty cycle VR = Internal Ramp Voltage (calculated in Rampadj section of this data sheet) This ramp voltage should be set to at least 0.5 V for noise immunity reasons. If it is less than 0.5 V then decrease the ramp resistor. (eq. 12) VOUT_ TRIM CODE VR (eq. 14) http://onsemi.com 15 ADP4000 Power Good Monitoring The transition slew rate is programmed using Bits <2:0> of the Ton_Transition (0xD6) command code. Table 6 provides the soft--start values. The power good comparator monitors the output voltage via the CSREF pin. The PWRGD pin is an open-drain output whose high level (when connected to a pull-up resistor) indicates that the output voltage is within the nominal limits specified in the specifications above based on the VID voltage setting. PWRGD goes low if the output voltage is outside of this specified range, if the VID DAC inputs are in no CPU mode, or whenever the EN pin is pulled low. PWRGD is blanked during a DVID event for a period of 100 ms to prevent false signals during the time the output is changing. The PWRGD circuitry also incorporates an initial turn-on delay time (TD5). Prior to the SS voltage reaching the programmed VID DAC voltage and the PWRGD masking time finishing, the PWRGD pin is held low. Once the SS circuit reaches the programmed DAC voltage, the internal timer operates. The default range for the PWRGD comparator is +300 mV and --500 mV. However these values can be adjusted over the PMBus. The high limit is programmed using Bits <1:0> of Command Code 0xE0 and the low limit is programmed using Bits <2:0> of Command code 0xE1. The following is a table of the programmable values. Table 6. Transition Rate Codes Code Transition Rate (V/msec) 000 1 001 3 = default 010 5 011 7 100 9 101 11 110 13 111 15 Enhanced Transients Mode The ADP4000 incorporates enhanced transient response for both load step up and load release. For load step up it senses the output of the error amp to determine if a load step up has occurred and then sequences on the appropriate number of phases to ramp up the output current. For load release, it also senses the output of the error amp and uses the load release information to trigger the TRDET pin, which is then used to adjust the error amp feedback for optimal positioning. This is especially important during high frequency load steps. Additional information is used during load transients to ensure proper sequencing and balancing of phases during high frequency load steps as well as minimizing the stress on components such as the input filter and MOSFET’s. Table 7. PWRGD High Limits Code PWRGD High Limits 00 +300mV (default) 01 +250 mV 10 +200 mV 11 +150 mV TRDET and Phase Shuffling The ADP4000 senses the error amp output and triggers the TRDET pin when a load release takes place. The TRDET circuit, as shown in Figure 2, adjusts the feedback for optimal positioning especially during high frequency load steps. TRDET is also used to trigger phase shuffling. If repeated transients take place at the switching frequency then its possible for one phase to carry most of the currrent. To prevent this from happening the ADP4000 will shuffle the phases whenever a load release happens, i.e. it will randomize the phase sequence. Table 8. PWRGD Low Limits Reference Current The IREF pin is used to set an internal current reference. This reference current sets IFB and ITTSENSE. A resistor to ground programs the current based on the 1.8 V output. I REF = 1.8 V R IREF PWRGD Low Limits 000 -500mV (default) 001 -450 mV 010 -400 mV 011 -350 mV 100 -300 mV 101 -250 mV 110 -200 mV 111 -150 mV Power State Indicator The PSI pin is an input used to determine the operating state of the load. If this input is pulled low, the load is in a low power state and the controller asserts the ODN pin low, which can be used to disable phases and maintain better efficiency at lighter loads. The sequencing into and out of low power operation is maintained to minimize output deviations as well as providing full power load transients immediately after exiting a low power state. (eq. 16) Typically, RIREF is set to 121 kΩ to program IREF = 15 mA. The following currents are then equal to I FB = 16 × I REF = 16 mA 15 Code (eq. 17) I TTSENSE = − 8 (IREF) = − 120 mA http://onsemi.com 16 ADP4000 Output Enable and UVLO The user can program how many phases are enabled when PSI is asserted. By default only phase 1 is enabled. The number of phases enabled can be changed over the PMBus. However extreme care should be taken to ensure that OD1 is connected to all phases enabled during PSI. The number of phases enabled during PSI is programmed using Bits 7 and 6 of the MFR Config Command (0xD1) For the ADP4000 to begin switching, the input supply current to the controller must be higher than the UVLO threshold and the EN pin must be higher than its 0.8 V threshold. This initiates a system startup sequence. If either UVLO or EN is less than their respective thresholds, the ADP4000 is disabled. This holds the PWM outputs at ground and forces PWRGD, ODN and OD1 signals low. In the application circuit (see Figure 2), the OD1 pin should be connected to the OD inputs of the external drivers for the phases that are always on. The ODN pin should be connected to the OD inputs of the external drivers on the phases that are shut down during low power operation. Grounding the driver OD inputs disables the drivers such that both DRVH and DRVL are grounded. This feature is important in preventing the discharge of the output capacitors when the controller is shut off. If the driver outputs are not disabled, a negative voltage can be generated during output due to the high current discharge of the output capacitors through the inductors. Table 9. # Phases Enabled During PSI # of Phases Running Normally Code # of Phases Running During PSI 6 00 1 1 01 2 1 and 4 10 3 1, 3 and 5 11 1 1 00 1 1 01 2 1 and 4 10 1 1 11 1 1 00 1 1 01 2 1 and 3 10 1 1 5 4 3 2 1 Phases Running 11 1 1 00 1 1 01 1 1 10 1 1 11 1 1 00 1 1 01 1 1 10 1 1 11 1 1 00 1 1 01 1 1 10 1 1 11 1 1 Thermal Monitoring The ADP4000 includes a thermal monitoring channel using a thermistor. Temperature trip points can be set for ALERT and FAULT levels through the PMBus interface. Also, the temperature values can be read back over the PMBus interface. The VR thermal monitoring circuits require an NTC thermistor to be placed from TTSENSE to GND. For best accuracy, the thermistors can be linearized using resistors. A fixed current of 8 times IREF (normally giving 120 mA) is sourced out of the TTSENSE pin into the thermistor. When the TTSENSE temperature exceeds the OT Fault Limit (0x51), VRHOT is asserted. The temperature value is reported back in the Read_Temperature1 command. The AP4000 measures the voltage on the TTSENSE pin and calculates the temperature using the following formula: Read_Temperature_1 = (TTSENSE Voltage)*TTSENSE Gain + TTSENSE Offset. The TTSENSE Gain and Offset factors depend upon the combination of thermistor and linearizing register used in the circuit and can be programmed by the user using commands TTSENSE Gain (addr = 0xF7) and TTSENSE Offset (addr = 0xF8). The default values in the ADP4000 are for a 100 k Thermistor and a 20 k Linearizing resistor. If the user would like to measure the voltage directly then the TTSENSE Gain should be programmed to 1 and the Offset should be programmed to 0. The actual phases enabled depend upon how many phases are enabled for normal operation. For example if 4 phases are enabled normally and 2 during PSI, then Phase 1 and Phase 3 will be enabled during PSI. Output Crowbar As part of the protection for the load and output components of the supply, the PWM outputs are driven low (turning on the low-side MOSFETs) when the output voltage exceeds the upper crowbar threshold. This crowbar action stops once the output voltage falls below the release threshold of approximately 300 mV. The value for the crowbar limit follows the programmable PWRGD high limit. Turning on the low-side MOSFETs pulls down the output as the reverse current builds up in the inductors. If the output overvoltage is due to a short in the high--side MOSFET, this action current-limits the input supply or blows its fuse, protecting the microprocessor from being destroyed. Voltage Monitoring The ADP4000 can monitor up to three voltages. It can monitor the voltage on the EN pin and reports this back in a register. It can also monitor the voltage on the VSENSE1 and the VSENSE2 pins and report these back in registers over PMBus. The ADC range for the voltage measurements http://onsemi.com 17 ADP4000 PMBus Interface is 0 V to 2.0 V. Voltages greater than 2.0 V can monitored using a resistor divider network. Voltage measurements are 10 bits wide. Vsense1 is intended to measure the input voltage and report this back in the READ_VIN command. However the input voltage is typically 12 V and the ADC range is only 0 V to 2.0 V. Therefore an external resistor divided is needed, the ADP4000 assumes that an 8--1 resistor divider is used, the ADP4000 measures the voltage on the pin and multiples by 8 and places the result in the Read Vin register. The circuit in Figure 2 uses a 6.8 K and a 1.0 k resistor to divide the input voltage by 8. Control of the ADP4000 is carried out using the PMBus Interface. The physical protocol for PMBus closely matches that of SMBus. The ADP4000 is connected to this bus as a slave device, under the control of a master controller. To setup the PMBus Address the ADP4000 sources a 10 mA current from the ADD pin through an external resistor. The voltage is then measured by the ADC and user to set the PMBus address. The table below gives the thresholds for each possible PMBus address. Table 10. Setting Up the PMBus Address Shunt Resistor The ADP4000 uses a shunt to generate 5.0 V from the 12 V supply range. A trade-off can be made between the power dissipated in the shunt resistor and the UVLO threshold. Figure 10 shows the typical resistor value needed to realize certain UVLO voltages. It also gives the maximum power dissipated in the shunt resistor for these UVLO voltages. High Threshold Low Threshold 0xC0 0.1 -- 0xC2 0.225 0.15 0xC4 0.45 0.3 0xC6 0.675 0.5 0xC8 0.9 0.75 0xCA 1.25 1.0 0xCC 1.7 1.35 0xCE -- 1.8 0.325 400 Data is sent over the serial bus in sequences of nine clock pulses: eight bits of data followed by an acknowledge bit from the slave device. Transitions on the data line must occur during the low period of the clock signal and remain stable during the high period, because a low--to--high transition when the clock is high might be interpreted as a stop signal. The number of data bytes that can be transmitted over the serial bus in a single read or write operation is limited only by what the master and slave devices can handle. 1. When all data bytes have been read or written, stop conditions are established. In write mode, the master pulls the data line high during the tenth clock pulse to assert a stop condition. In read mode, the master device overrides the acknowledge bit by pulling the data line high during the low period before the ninth clock pulse; this is known as No Acknowledge. The master takes the data line low during the low period before the tenth clock pulse, and then high during the tenth clock pulse to assert a stop condition. Any number of bytes of data can be transferred over the serial bus in one operation, but it is not possible to mix read and write in one operation because the type of operation is determined at the beginning and cannot subsequently be changed without starting a new operation. In the ADP4000, write operations contain one, two or three bytes, and read operations contain one or two bytes. The command code or register address 0.3 350 0.275 Rshunt 300 0.25 250 0.225 200 150 Address (8 Bits) Pshunt 2--0603 Limit 2--0805 Limit 0.2 0.175 8 9 10 11 12 13 14 15 16 ICC (UVLO) Figure 10. Typical Shunt Resistor Value and Power Dissipation for Different UVLO Voltage The maximum power dissipated is calculated using the Equation 18. P MAX = VIN(MAX) − VCC(MIN) R SHUNT 2 (eq. 18) where: VIN(MAX) is the maximum voltage from the 12 V input supply (if the 12 V input supply is 12 V ±5%, VIN(MAX) = 12.6 V; if the 12 V input supply is 12 V ±10%, VIN(MAX) = 13.2 V). VCC(MIN) is the minimum VCC voltage of the ADP4000. This is specified as 4.75 V. RSHUNT is the shunt resistor value. The CECC standard specification for power rating in surface-mount resistors is: 0603 = 0.1 W, 0805 = 0.125 W, 1206 = 0.25 W. http://onsemi.com 18 ADP4000 2. The read byte operation is shown in Figure 13. First the command code needs to be written to the ADP4000 so that the required data is sent back. This is done by performing a write to the ADP4000 as before, but only the data byte containing the register address is sent, because no data is written to the register. A repeated start is then issued and a read operation is then performed consisting of the serial bus address; R/W bit set to 1, followed by the data byte read from the data register. 3. It is not possible to read or write a data byte from a data register without first writing to the address pointer register, even if the address pointer register is already at the correct value. 4. In addition to supporting the send byte, the ADP4000 also supports the read byte, write byte, read word and write word protocols. determines the number of bytes to be read or written, See the register map for more information. To write data to one of the device data registers or read data from it, the address pointer register must be set so that the correct data register is addressed (i.e. command code), and then data can be written to that register or read from it. The first byte of a read or write operation always contains an address that is stored in the address pointer register. If data is to be written to the device, the write operation contains a second data byte that is written to the register selected by the address pointer register. This write byte operation is shown in Figure 12. The device address is sent over the bus, and then R/W is set to 0. This is followed by two data bytes. The first data byte is the address of the internal data register to be written to, which is stored in the address pointer register. The second data byte is the data to be written to the internal data register. 9 1 9 1 SCL 1 SDA 10 0 START BY MASTER 0 A1 A0 D6 D7 R/W D4 D5 D2 D3 D1 D0 ACK. BY ADP4000 FRAME 1 SERIAL BUS ADDRESS BYTE ACK. BY ADP4000 STOP BY MASTER FRAME 2 COMMAND CODE Figure 11. Send Byte 1 9 9 1 SCL SDA START BY MASTER 1 1 0 0 0 A1 A0 D7 R/W D6 D5 D4 D3 D2 D1 D0 ACK. BY ADP4000 ACK. BY ADP4000 FRAME 1 SERIAL BUS ADDRESS BYTE FRAME 2 COMMAND CODE 1 9 SCL (CONTINUED) SDA (CONTINUED) D7 D6 D5 D4 D3 FRAME 3 D ATA BYTE Figure 12. Write Byte http://onsemi.com 19 D2 D1 D0 ACK. BY ADP4000 STOP BY MASTER ADP4000 1 9 1 9 SCL 1 SDA 10 0 START BY MASTER 0 A1 A0 D7 R/W D6 D4 D5 D3 D2 D1 D0 ACK. BY ADP4000 FRAME 1 SERIAL BUS ADDRESS BYTE ACK. BY ADT4000 FRAME 2 COMMAND CODE 1 9 9 1 SCL SDA 1 1 REPEATED START BY MASTER 0 0 0 A1 A0 FRAME 1 SERIAL BUS ADDRESS BYTE R/W D7 D6 D4 D5 D3 D2 D1 D0 STOP BY MASTER NO ACK. BY MASTER ACK. BY ADP4000 FRAME 2 DATA BYTE FROM ADP4000 Figure 13. Read Byte Write Operations out a single byte read without asserting an intermediate stop condition. The PMBus specification defines several protocols for different types of read and write operations. The ones used in the ADP4000 are discussed in this section. The following abbreviations are used in the diagrams: Write Byte In this operation, the master device sends a command byte and one data byte to the slave device as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends a command code. 5. The slave asserts ACK on SDA. 6. The master sends a data byte. 7. The slave asserts ACK on SDA. 8. The master asserts a stop condition on SDA and the transaction ends. The byte write operation is shown in Figure 15. S--START P--STOP R--READ W--WRITE A--ACKNOWLEDGE A--NO ACKNOWLEDGE The ADP4000 uses the following PMBus write protocols. Send Byte In this operation, the master device sends a single command byte to a slave device as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends a command code. 5. The slave asserts ACK on SDA. 6. The master asserts a stop condition on SDA and the transaction ends. For the ADP4000, the send byte protocol is used to clear Faults. This operation is shown in Figure 14. 1 2 3 SLAVE S W A ADDRESS 4 5 6 COMMAND CODE A P 1 2 3 SLAVE S W A ADDRESS 4 COMMAND CODE 5 6 7 8 A DATA A P Figure 15. Single Byte Write to a Register Write Word In this operation, the master device sends a command byte and two data bytes to the slave device as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends a command code. 5. The slave asserts ACK on SDA. 6. The master sends the first data byte. 7. The slave asserts ACK on SDA. Figure 14. Send Byte Command If the master is required to read data from the register immediately after setting up the address, it can assert a repeat start condition immediately after the final ACK and carry http://onsemi.com 20 ADP4000 7. The master sends the 7 bit slave address followed by the read bit (high). 8. The slave asserts ACK on SDA. 9. The slave sends the Data Byte. 10. The master asserts NO ACK on SDA. 11. The master asserts a stop condition on SDA and the transaction ends. 8. The master sends the second data byte. 9. The slave asserts ACK on SDA. 10. The master asserts a stop condition on SDA and the transaction ends. The word write operation is shown in Figure 16. 1 2 3 SLAVE S W A ADDRESS 4 5 COMMAND CODE 6 7 8 9 10 DATA DATA A A A P (LSB) (MSB) 1 2 Figure 16. Single Word Write to a Register Block Write 2 3 SLAVE S W A ADDRESS 4 5 COMMAND CODE 10 DATA BYTE 2 11 A A ... ... 6 7 BYTE COUNT A =N 12 DATA BYTE N 13 A 8 4 5 COMMAND CODE 6 7 8 9 10 11 SLAVE A S R A DATA A ADDRESS P Figure 18. Single Read from a Register In this operation, the master device sends a command byte and a byte count followed by the stated number of data bytes to the slave device as follows: 1. The master device asserts a START condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends a command code. 5. The slave asserts ACK on SDA. 6. The master sends the byte count N. 7. The slave asserts ACK on SDA. 8. The master sends the first data byte. 9. The slave asserts ACK on SDA. 10. The master sends the second data byte. 11. The slave asserts ACK on SDA. 12. The master sends the remainder of the data byes. 13. The slave asserts an ACK on SDA after each data byte. 14. After the last data byte the master asserts a STOP condition on SDA. 1 3 SLAVE S W A ADDRESS Read Word In this operation, the master device receives two data bytes from a slave device as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends a command code. 5. The slave asserted ACK on SDA. 6. The master sends a repeated start condition on SDA. 7. The master sends the 7 bit slave address followed by the read bit (high). 8. The slave asserts ACK on SDA. 9. The slave sends the first Data Byte (low Data Byte). 10. The master asserts ACK on SDA. 11. The slave sends the second Data Byte (high Data Byte). 12. The masters asserts a No ACK on SDA. 13. The master asserts a stop condition on SDA and the transaction ends. 9 DATA A BYTE 1 1 2 3 SLAVE S W A ADDRESS 14 4 COMMAND CODE 5 6 7 8 11 P 9 10 SLAVE DATA A S R A A ADDRESS (LSB) 12 13 DATA A P (MSB) Figure 17. Block Write to a Register Figure 19. Word Read from a Command Code Read Operations The ADP4000 uses the following PMBus read protocols. Block Read In this operation, the master device sends a command byte, the slave sends a byte count followed by the stated number of data bytes to the master device as follows: 1. The master device asserts a START condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends a REPEATED START condition on SDA. Read Byte In this operation, the master device receives a single byte from a slave device as follows: 1. The master device asserts a start condition on SDA. 2. The master sends the 7-bit slave address followed by the write bit (low). 3. The addressed slave device asserts ACK on SDA. 4. The master sends a command code. 5. The slave asserted ACK on SDA. 6. The master sends a repeated start condition on SDA. http://onsemi.com 21 ADP4000 Operation Command 5. The master sends the 7-bit slave address followed by the read bit (high). 6. The slave asserts ACK on SDA 7. The slave sends the byte count N. 8. The master asserts ACK on SDA. 9. The slave sends the first data byte 10. The master asserts ACK on SDA. 11. The slave sends the remainder of the data byes, the master asserts an ACK on SDA after each data byte. 12. After the last data byte the master asserts a No ACK on SDA. 13. The master asserts a STOP condition on SDA. 1 2 3 4 5 6 The operation command, when enabled in the ON_OFF_Config command, can be used to start and stop the ADP4000 switching. The options available described in the Operation Command (0x01) in Table 11. There are two options for turning off, soft off and immediate off. There are three options for turning on. The first is ON, where the output voltage is soft started towards the Boot Voltage and then to the VID Voltage (same startup sequence as toggling EN). The other two options are margin high and margin low. When these options are selected the output voltage will settle on the VOUT_MARGIN_HIGH VID Code (0x25) or the VOUT_MARGIN_LOW VID Code (0x26). 7 Limits, ALERTs, and FAULTs SLAVE SLAVE BYTE COUNT S W A S R A ADDRESS ADDRESS =N 8 9 10 A DATA BYTE 1 A ... 11 12 13 DATA BYTE N A P The ADP4000 monitors a number of voltage rails, temperatures, current etc. For each of the measured values there are ALERT and FAULT limits. When an ALERT or FAULT limit is exceeded then the ALERT or FAULT pin is asserted low and will remain low until the PMBus master does a Clear_Faults command and the measured value is back within the programmed limits. Take for example the temperature measurement Read_Temperature1 (0x8D). This value is compared with the OT_WARN_LIMIT (0x51) and the UT_WARN_LIMIT (0x52). If the measured temperature goes above the OT_WARN_LIMIT or under the UT_WARN_LIMIT then the corresponding Status bit is set Status_Temperature Command (0x7D) and an ALERT pin is pulled low. The ALERT pin will remain low until the PMBus master does a Clear_Faults command (0x03) and the measured temperature is back within the programmed limits. If the measured temperature exceeds the OT_FAULT_LIMIT (0x51) then Bit 7 of the Status_Temperature command gets set and the FAULT pin is asserted low. The intention is that a FAULT condition is worse than an ALERT condition. Each measured value is compared with appropriate high and low limits and the results of these comparisons are stored in Status Registers. See details of the various status registers in Table 11, commands 0x78, STATUS BYTE to 0x80 STATUS ALERT. The ADP4000 also allows the user to program which measured values can generate an ALERT and a FAULT using the Mask ALERT (0xF9) and Mask FAULT (0xFA) Commands. If the Mask VOUT Bit (Bit 7 is set in the Mask ALERT command) then the measured Vout going outside the programmed limits will set the appropriate Status bit but will not assert ALERT pin low. See command codes 0xF9 and 0xFA in Table 11 for more details. Figure 20. Block Write to a Command Coder PMBus Timeout The ADP4000 includes an PMBus timeout feature. If there is no PMBus activity for 35 ms, the ADP4000 assumes that the bus is locked and releases the bus. This prevents the device from locking or holding the PMBus expecting data. Some PMBus controllers cannot handle the PMBus timeout feature, so it can be disabled. Configuration Register 1 (0xTBD) Bit 3 SMB_TO_EN = 1; PMBus timeout enabled. Bit 3 TODIS = 0; PMBus timeout disabled (default). Virus Protection To prevent rogue programs or viruses from accessing critical ADP4000 register settings, the lock bit can be set. Setting Bit 0 of the Lock/Reset sets the lock bit and locks critical registers. In this mode, certain registers can no longer be written to until the ADP4000 is powered down and powered up again. For more information on which registers are locked see the register map. ON_OFF_Config Command The PMBus specifies an ON_OFF_Config which allows the user to configure when the ADP4000 should start and stop switching. There two control inputs, the EN input (specified as per VR11.1) and the Operation Command. The user can program the ADP4000 to respond to or ignore each of the control inputs. The default configuration is the EN pin is acted on, and the Operation Command is ignored. The EN pin is active high by default but can be programmed to be active low over PMBus. The details of the individual bits can be found in the description for Command Code 0x02 (ON_OFF_Config) in Table 11. Linear Mode PMBus specifies two data format used for reporting back voltage, current and temperatures etc and for programming http://onsemi.com 22 ADP4000 Limits. The ADP4000 uses Linear Mode. Linear Mode can be decoded as follows: X = Y*2^N the PMBus spec says this register should read back Amps. Therefore the IOUT_CAL_GAIN and IOUT_CAL_OFFSET commands need to be programmed to convert the Imon voltage into current in Amps. The following equation is used: READ_IOUT = Imon Voltage × IOUT_CAL_GAIN Where X = the value (for example if this is current then it would be Amps, Temperature it would be °C etc). The register readback is 16 Bits, the 5 MSB’s are the Exponent (=N) and the 11 LSB’s are the mantissa (=Y). Both the mantissa and exponent are 2’s compliment values, if the MSB are 1 then they are negative values. + IOUT_CAL_OFFSET (eq. 19) The IOUT_CAL_GAIN defaults to 1 and IOUT_CAL_OFFSET defaults to 0 which means the Imon voltage is stored in the READ_IOUT Command. IOUT_CAL_GAIN and IOUT_CAL_OFFSET The ADP4000 measures the voltage on the Imon pin and stores that in the READ_IOUT Command (0x8C). However http://onsemi.com 23 ADP4000 VR11 VID CODES for the ADP4000 OUTPUT VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 OFF 0 0 0 0 0 0 0 0 OFF 0 0 0 0 0 0 0 1 1.60000 0 0 0 0 0 0 1 0 1.59375 0 0 0 0 0 0 1 1 1.58750 0 0 0 0 0 1 0 0 1.58125 0 0 0 0 0 1 0 1 1.57500 0 0 0 0 0 1 1 0 1.56875 0 0 0 0 0 1 1 1 1.56250 0 0 0 0 1 0 0 0 1.55625 0 0 0 0 1 0 0 1 1.55000 0 0 0 0 1 0 1 0 1.54375 0 0 0 0 1 0 1 1 1.53750 0 0 0 0 1 1 0 0 1.53125 0 0 0 0 1 1 0 1 1.52500 0 0 0 0 1 1 1 0 1.51875 0 0 0 0 1 1 1 1 1.51250 0 0 0 1 0 0 0 0 1.50625 0 0 0 1 0 0 0 1 1.50000 0 0 0 1 0 0 1 0 1.49375 0 0 0 1 0 0 1 1 1.48750 0 0 0 1 0 1 0 0 1.48125 0 0 0 1 0 1 0 1 1.47500 0 0 0 1 0 1 1 0 1.46875 0 0 0 1 0 1 1 1 1.46250 0 0 0 1 1 0 0 0 1.45625 0 0 0 1 1 0 0 1 1.45000 0 0 0 1 1 0 1 0 1.44375 0 0 0 1 1 0 1 1 1.43750 0 0 0 1 1 1 0 0 1.43125 0 0 0 1 1 1 0 1 1.42500 0 0 0 1 1 1 1 0 1.41875 0 0 0 1 1 1 1 1 1.41250 0 0 1 0 0 0 0 0 1.40625 0 0 1 0 0 0 0 1 1.40000 0 0 1 0 0 0 1 0 1.39375 0 0 1 0 0 0 1 1 1.38750 0 0 1 0 0 1 0 0 1.38125 0 0 1 0 0 1 0 1 1.37500 0 0 1 0 0 1 1 0 1.36875 0 0 1 0 0 1 1 1 1.36250 0 0 1 0 1 0 0 0 1.35625 0 0 1 0 1 0 0 1 1.35000 0 0 1 0 1 0 1 0 1.34375 0 0 1 0 1 0 1 1 1.33750 0 0 1 0 1 1 0 0 1.33125 0 0 1 0 1 1 0 1 http://onsemi.com 24 ADP4000 VR11 VID CODES for the ADP4000 OUTPUT VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 1.32500 0 0 1 0 1 1 1 0 1.31875 0 0 1 0 1 1 1 1 1.31250 0 0 1 1 0 0 0 0 1.30625 0 0 1 1 0 0 0 1 1.30000 0 0 1 1 0 0 1 0 1.29375 0 0 1 1 0 0 1 1 1.28750 0 0 1 1 0 1 0 0 1.28125 0 0 1 1 0 1 0 1 1.27500 0 0 1 1 0 1 1 0 1.26875 0 0 1 1 0 1 1 1 1.26250 0 0 1 1 1 0 0 0 1.25625 0 0 1 1 1 0 0 1 1.25000 0 0 1 1 1 0 1 0 1.24375 0 0 1 1 1 0 1 1 1.23750 0 0 1 1 1 1 0 0 1.23125 0 0 1 1 1 1 0 1 1.22500 0 0 1 1 1 1 1 0 1.21875 0 0 1 1 1 1 1 1 1.21250 0 1 0 0 0 0 0 0 1.20625 0 1 0 0 0 0 0 1 1.20000 0 1 0 0 0 0 1 0 1.19375 0 1 0 0 0 0 1 1 1.18750 0 1 0 0 0 1 0 0 1.18125 0 1 0 0 0 1 0 1 1.17500 0 1 0 0 0 1 1 0 1.16875 0 1 0 0 0 1 1 1 1.16250 0 1 0 0 1 0 0 0 1.15625 0 1 0 0 1 0 0 1 1.15000 0 1 0 0 1 0 1 0 1.14375 0 1 0 0 1 0 1 1 1.13750 0 1 0 0 1 1 0 0 1.13125 0 1 0 0 1 1 0 1 1.12500 0 1 0 0 1 1 1 0 1.11875 0 1 0 0 1 1 1 1 1.11250 0 1 0 1 0 0 0 0 1.10625 0 1 0 1 0 0 0 1 1.10000 0 1 0 1 0 0 1 0 1.09375 0 1 0 1 0 0 1 1 1.08750 0 1 0 1 0 1 0 0 1.08125 0 1 0 1 0 1 0 1 1.07500 0 1 0 1 0 1 1 0 1.06875 0 1 0 1 0 1 1 1 1.06250 0 1 0 1 1 0 0 0 1.05625 0 1 0 1 1 0 0 1 1.05000 0 1 0 1 1 0 1 0 1.04375 0 1 0 1 1 0 1 1 http://onsemi.com 25 ADP4000 VR11 VID CODES for the ADP4000 OUTPUT VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 1.03750 0 1 0 1 1 1 0 0 1.03125 0 1 0 1 1 1 0 1 1.02500 0 1 0 1 1 1 1 0 1.01875 0 1 0 1 1 1 1 1 1.01250 0 1 1 0 0 0 0 0 1.00625 0 1 1 0 0 0 0 1 1.00000 0 1 1 0 0 0 1 0 0.99375 0 1 1 0 0 0 1 1 0.98750 0 1 1 0 0 1 0 0 0.98125 0 1 1 0 0 1 0 1 0.97500 0 1 1 0 0 1 1 0 0.96875 0 1 1 0 0 1 1 1 0.96250 0 1 1 0 1 0 0 0 0.95625 0 1 1 0 1 0 0 1 0.95000 0 1 1 0 1 0 1 0 0.94375 0 1 1 0 1 0 1 1 0.93750 0 1 1 0 1 1 0 0 0.93125 0 1 1 0 1 1 0 1 0.92500 0 1 1 0 1 1 1 0 0.91875 0 1 1 0 1 1 1 1 0.91250 0 1 1 1 0 0 0 0 0.90625 0 1 1 1 0 0 0 1 0.90000 0 1 1 1 0 0 1 0 0.89375 0 1 1 1 0 0 1 1 0.88750 0 1 1 1 0 1 0 0 0.88125 0 1 1 1 0 1 0 1 0.87500 0 1 1 1 0 1 1 0 0.86875 0 1 1 1 0 1 1 1 0.86250 0 1 1 1 1 0 0 0 0.85625 0 1 1 1 1 0 0 1 0.85000 0 1 1 1 1 0 1 0 0.84375 0 1 1 1 1 0 1 1 0.83750 0 1 1 1 1 1 0 0 0.83125 0 1 1 1 1 1 0 1 0.82500 0 1 1 1 1 1 1 0 0.81875 0 1 1 1 1 1 1 1 0.81250 1 0 0 0 0 0 0 0 0.80625 1 0 0 0 0 0 0 1 0.80000 1 0 0 0 0 0 1 0 0.79375 1 0 0 0 0 0 1 1 0.78750 1 0 0 0 0 1 0 0 0.78125 1 0 0 0 0 1 0 1 0.77500 1 0 0 0 0 1 1 0 0.76875 1 0 0 0 0 1 1 1 0.76250 1 0 0 0 1 0 0 0 0.75625 1 0 0 0 1 0 0 1 http://onsemi.com 26 ADP4000 VR11 VID CODES for the ADP4000 OUTPUT VID7 VID6 VID5 VID4 VID3 VID2 VID1 VID0 0.75000 1 0 0 0 1 0 1 0 0.74375 1 0 0 0 1 0 1 1 0.73750 1 0 0 0 1 1 0 0 0.73125 1 0 0 0 1 1 0 1 0.72500 1 0 0 0 1 1 1 0 0.71875 1 0 0 0 1 1 1 1 0.71250 1 0 0 1 0 0 0 0 0.70625 1 0 0 1 0 0 0 1 0.70000 1 0 0 1 0 0 1 0 0.69375 1 0 0 1 0 0 1 1 0.68750 1 0 0 1 0 1 0 0 0.68125 1 0 0 1 0 1 0 1 0.67500 1 0 0 1 0 1 1 0 0.66875 1 0 0 1 0 1 1 1 0.66250 1 0 0 1 1 0 0 0 0.65625 1 0 0 1 1 0 0 1 0.65000 1 0 0 1 1 0 1 0 0.64375 1 0 0 1 1 0 1 1 0.63750 1 0 0 1 1 1 0 0 0.63125 1 0 0 1 1 1 0 1 0.62500 1 0 0 1 1 1 1 0 0.61875 1 0 0 1 1 1 1 1 0.61250 1 0 1 0 0 0 0 0 0.60625 1 0 1 0 0 0 0 1 0.60000 1 0 1 0 0 0 1 0 0.59375 1 0 1 0 0 0 1 1 0.58750 1 0 1 0 0 1 0 0 0.58125 1 0 1 0 0 1 0 1 0.57500 1 0 1 0 0 1 1 0 0.56875 1 0 1 0 0 1 1 1 0.56250 1 0 1 0 1 0 0 0 0.55625 1 0 1 0 1 0 0 1 0.55000 1 0 1 0 1 0 1 0 0.54375 1 0 1 0 1 0 1 1 0.53750 1 0 1 0 1 1 0 0 0.53125 1 0 1 0 1 1 0 1 0.52500 1 0 1 0 1 1 1 0 0.51875 1 0 1 0 1 1 1 1 0.51250 1 0 1 1 0 0 0 0 0.50625 1 0 1 1 0 0 0 1 0.50000 1 0 1 1 0 0 1 0 OFF 1 1 1 1 1 1 1 0 OFF 1 1 1 1 1 1 1 1 http://onsemi.com 27 ADP4000 Table 11. PMBus Commands for the ADP4000 Cmd Code R/W Default Description # Byte Comment 0x01 R/W 0x80 Operation 1 00xx xxxx – Immediate Off 01xx xxxx – Soft Off 1000 xxxx – On (slew rate set by soft--start) - Default 1001 10xx – Margin Low (Act on Fault) 1010 10xx – Margin High (Act on Fault) 0x02 R/W 0x17 ON_OFF_Config 1 Configures how the controller is turned on and off Bit Default 7:5 1 Reserved for Future Use Comment 4 0 This bit is read only. Switching starts when commanded by the Control Pin and the Operation Command, as set in Bits 3:0 3 1 0: Unit ignores OPERATION commands over the PMBus 1: Unit responds to OPERATION command, powerup may also depend upon Control input, as described in Bit 2 2 1 0: Unit ignores EN pin 1: Unit responds EN pin, powerup may also depend upon the Operation Register, as described for Bit 3 1 1 Control Pin Polarity 0 = Active Low 1 = Active High 0 1 This bit is read only. 1 means that when the controller is disabled it will either immediately turn off or soft off (as set in the Operation Command) 0x03 W NA Clear_Faults 0 Writing any value to this command code will clear all Status Bits immediately. The SMBus ALERT is deasserted on this command. If the fault is still present the fault bit shall immediately be asserted again. 0x10 R/W 0x00 Write Protect 1 The Write_Protect command is used to control writing to the PMBus device. There is also a lock bit in the Manufacture Specific Registers that once set will disable writes to all commands until the power to the ADP4000 is cycled. Data Byte 0x19 R 0xB0 Capability 1 Comment 1000 0000 Disables all writes except to the Write_Protect Command 0100 0000 Disables all writes except to the Write_Protect and Operation Commands 0010 0000 Disables all writes except to the Write_Protect, Operation, ON_OFF_Config and VOUT_COMMAND Commands 0000 0000 Enables writes to all commands 0001 0000 Disables all writes except to WRITE_PROTECT, PAGE and all MFR-SPECIFIC Commands This command allows the host to get some information on the PMBus device. Bit Default 7 1 PEC (Packet Error Checking is supported). 6:5 01 Max supported bus speed is 400 kHz. http://onsemi.com 28 Comment ADP4000 Cmd Code R/W Default Description # Byte Comment 4 1 3:0 000 ADP4000 has an SMBus ALERT pin and ARA is supported. Reserved 0x20 R 0x20 VOUT_MODE 1 The ADP4000 supports VID mode for programming the output voltage. 0x21 R/W 0x00 VOUT_COMMAND 2 Sets the output voltage using VID. 0x25 R/W 0x0020 VOUT_MARGIN_ HIGH 2 Sets the output voltage when operation command is set to Margin High. Programmed in VID Mode. 0x26 R/W 0x00B2 VOUT_MARGIN_ LOW 2 Sets the output voltage when operation command is set to Margin Low. Programmed in VID Mode. 0x38 R/W 0x0001 IOUT_CAL_GAIN 2 Sets the ratio of voltage sensed to current output. Scale is Linear and is expressed in 1/Ω 0x39 R/W 0x0000 IOUT_CAL_OFFSET 2 This offset is used to null out any offsets in the output current sensing circuitry. Programmed in Linear mode and units are Amps. 0x4A R/W 0x0064 IOUT_OC_WARN_ LIMIT 2 This sets the high current--limit. Once this limit is exceeded IOUT_OC_WARN_LIMIT bit is set in the Status_IOUT register and an ALERT is generated. This limit is set in Amps and programmed in Linear Mode. 0x4F R/W 0x0055 OT_FAULT_LIMIT 2 This sets the temperature limit above which the Over Temp Fault Bit gets set in the Status_TEMPERATURE Register and the FAULT Output gets asserted. This limit is set using Linear Mode in °C. 0x51 R/W 0x0046 OT_WARN_LIMIT 2 This sets the temperature limit above which the Over Temp Warn Bit gets set in the Status_TEMPERATURE Register and the ALERT Output gets asserted. This limit is set using Linear Mode in °C. 0x52 R/W 0x0000 UT_WARN_LIMIT 2 This sets the temperature limit below which the Under Temp Warn Bit gets set in the Status_TEMPERATURE Register and the ALERT Output gets asserted. This limit is set using Linear Mode in °C. 0x55 R/W 0x0010 VIN_OV_FAULT LIMIT 2 This sets the input over voltage fault limit. Once exceeded the VIN Overvoltage Fault Bit, Bit 7, gets set in the Status Input Register and the FAULT output is asserted. This limit is set using Linear Mode, in V. 0x57 R/W 0x0010 VIN_OV_WARN LIMIT 2 This sets the input over voltage warn limit. Once exceeded the VIN Overvoltage Warn Bit, Bit 6, gets set in the Status Input Register and the ALERT output is asserted. This limit is set using Linear Mode, in V. 0x58 R/W 0x0000 VIN_UV_WARN LIMIT 2 This sets the input under voltage warn limit. Once exceeded the VIN Undervoltage Warn Bit, Bit 5, gets set in the Status Input Register and the ALERT output is asserted. This limit is set using Linear Mode, in V. 0x68 R/W 0x012C POUT_OP_ FAULT LIMIT 2 This sets the output power over power fault limit. Once exceeded Bit 1 of the Status IOUT Command gets set and the FAULT output gets asserted (if not masked). This limit is set using Linear Mode in W. 0x6A R/W 0x012C POUT_OP_ WARN LIMIT 2 This sets the output power over power warn limit. Once exceeded Bit 0 of the Status IOUT Command gets set and the ALERT output gets asserted (if not masked). This limit is set using Linear Mode in W. 0x78 R 0x00 STATUS BYTE 1 Bit Name Comment 7 BUSY A fault was declared because the ADP4000 was busy and unable to respond. 6 OFF 5 VOUT_OV This bit gets set whenever the ADP4000 goes into OVP mode. 4 IOUT_OC This bit gets set whenever the ADP4000 latches off due to an over current event. 3 VIN_UV This bit gets set when the input voltage falls below its programmed FAULT limit. 2 TEMP This bit gets set when the Temperature, as measured using the THERMISTOR, exceeds its THERM and/or high or low limits. http://onsemi.com 29 This bit is set whenever the ADP4000 is not switching. ADP4000 Cmd Code 0x79 0x7A R/W R R Default 0x0000 0x00 Description STATUS WORD STATUS VOUT # Byte 2 1 Comment 1 CML A Communications, memory or logic fault has occurred. 0 None of the Above A fault has occurred which is not one of the above. Byte Bit Name Low 7 Res Reserved Low 6 OFF This bit is set whenever the ADP4000 is not switching. Low 5 VOUT _OV This bit gets set whenever the ADP4000 goes into OVP mode. Low 4 IOUT _OC This bit gets set whenever the ADP4000 latches off due to an over current event. Low 3 Res Low 2 TEMP Low 1 CML Low 6 None of the Above High 7 VOUT This bit gets set whenever the measured output voltage goes outside its power good limits or an OVP event has taken place, i.e. any bit in Status VOUT is set. High 6 Iout/Pout This bit gets set whenever the measured output current or power exceeds its warning limit or goes into OCP. i.e. any bit in Status IOUT is set. High 5 INPUT This bit gets set if the input voltage, as measured on VSENSE1 goes outside its programmed limits. i.e. any bit in Status VINPUT is set. High 4 MFR A manufacturer specific warning or fault has occurred. High 3 POWER _GOOD The Power--Good signal is deasserted. Same as Power--Good in General Status. High 2 Res High 1 OTHER High 0 Res Description Reserved This bit gets set when the Temperature, as measured using the THERMISTOR, exceeds its THERM and/or high or low limits. A Communications, memory or logic fault has occurred. A fault has occurred which is not one of the above. Reserved A Status bit in Status Other is asserted. Reserved Bit Name Description 7 VOUT_ OVERVOLTAGE FAULT This bit gets set whenever an OVP Event takes place. 6 VOUT_ OVERVOLTAGE WARNING This bit gets set whenever the measured output voltage goes above its Power--Good limit. 5 VOUT_ UNDERVOLTAGE WARNING This bit gets set whenever the measured output voltage goes below its Power--Good limit. 4 VOUT_ UNDERVOLTAGE FAULT Not applicable. http://onsemi.com 30 ADP4000 Cmd Code 0x7B 0x7C 0x7D R/W R R R Default 0x00 0x00 0x00 Description STATUS IOUT STATUS INPUT STATUS_ TEMPERATURE # Byte 1 1 1 Comment 3 VOUT_MAX Warning Not supported, Can’t program an output greater than max VID as there are no bits to program it. 2 TON_MAX_FAULT Not supported. 1 TOFF_MAX_ WARNING Not supported. 0 VOUT_TRACKING_ ERROR Not supported. Bit Name 7 IOUT Overcurrent Fault Description This bit gets set if the ADP4000 latches off due to an OCP Event. 6 Reserved 5 IOUT Overcurrent Warning 4 Reserved Reserved 3 Reserved Reserved 2 Reserved Reserved 1 POUT Over--Power Fault This bit gets set if the measured POUT exceeds the FAULT Limit. 0 POUT Over--Power Warning This bit gets set if the measured POUT exceeds the Warn Limit. Bit Name 7 VIN Overvoltage FAULT This bit gets set when the input voltage goes above its programmed FAULT limit. 6 VIN Overvoltage Warning This bit gets set when the input voltage goes above its programmed high limit. 5 Undervoltage Warning 4 Reserved Reserved 3 Reserved Reserved 2 Reserved Reserved 1 Reserved Reserved 0 Reserved Reserved Bit Name Description 7 Overtemperature FAULT This bit gets asserted when the temperature measured by the Thermistor connected to TTSENSE exceeds its THERM/FAULT Limit. 6 Overtemperature Warrning This bit gets asserted when the temperature measured by the Thermistor connected to TTSENSE exceeds its High Temperature Limit. 5 Undertemperature Warrning This bit gets asserted when the temperature measured by the Thermistor connected to TTSENSE exceeds its Low Temperature Limit. 4 Reserved Reserved 3 Reserved Reserved 2 Reserved Reserved 1 Reserved Reserved 0 Reserved Reserved http://onsemi.com 31 Reserved This bit gets set if IOUT exceeds its programmed high warning limit. Description This bit gets set when the input voltage falls below its programmed low limit. ADP4000 Cmd Code R/W Default 0x7E R 0x00 0x80 R 0x00 Description STATUS CML STATUS_ALERT # Byte 1 1 Comment Bit Name 7 Invalid or Unsupported Command Received Supported Description 6 Invalid or Unsupported Data Received Supported 5 PEC Failed Supported 4 Memory Fault Detected Not Supported 3 Processor Fault Detected Not Supported 2 Reserved Reserved 1 A communication fault other than the ones listed has occurred. Supported 0 Other memory or Logic Fault has occurred. Not Supported Bit Name 7 Reserved Reserved 6 Reserved Reserved 5 VSENSE2 FAULT 4 VSENSE2 OV WARN Gets asserted when VSENSE2 exceeds it programmed OV WARN limits. 3 VSENSE2 OV WARN Gets asserted when VSENSE2 exceeds it programmed UV WARN limits. 2 VMON WARN Gets asserted when VSENSE2 exceeds it programmed WARN limits. 1 VMON FAULT Gets asserted when VSENSE2 exceeds it programmed FAULT limits. 0 Reserved Description Gets asserted when VSENSE2 exceeds it programmed FAULT limits. Reserved 0x88 R 0x00 READ_VIN 2 Readback input voltage (measured using VSENSE1). Voltage is read back in Linear Mode 0x8B R 0x00 READ_VOUT 2 Readback output voltage. Voltage is read back in VID Mode. 0x8C R 0x00 READ_IOUT 2 Readback output current. Current is read back in Linear Mode (Amps). 0x8D R 0x00 READ_ TEMPERATURE1 2 Readback temperature 1. Thermistor, connected to TTSENSE is the sense element. Temperature is read back in Linear Mode °C. 0x96 R 0x00 READ_POUT 2 Readback Output Power, read back in Linear Mode in W’s. 0x99 R 0x41 MFR_ID 1 0x41 Readback using the Block command with the Byte count equal to 1. 0x9A R 0x4000 MFR_MODEL 2 0x4000 Readback using the Block command with the Byte count equal to 2. 0x9B R 0x01 MFR_REVISION 1 0 Readback using the Block command with the Byte count equal to 1. http://onsemi.com 32 ADP4000 Table 12. Manufacturer Specific Command Codes for the ADP4000 Cmd Code R/W Default 0xD0 R/W 0x00 0xD1 0xD2 R/W R/W 0x07 0x52 Description Lock/Reset Mfr Config VR Config 1A # Byte 1 1 1 Comment Bit Name Description 1 Reset Resets all registers to their POR Value. Has no effect if Lock bit is set. 0 Lock Logic 1 locks all limit values to their current settings. Once this bit is set, all lockable registers become read-only and cannot be modified until the ADP4000 is powered down and powered up again. This prevents rogue programs such as viruses from modifying critical system limit settings (Lockable). Bit Name 7:6 PSI Description 5 Reserved Reserved 4 Reserved Reserved 3 PMB_TO_EN 2 FAULT_EN Enable the FAULT pin, Default = 1 1 ALERT_EN Enable the ALERT pin 0 ENABLE_ MONITOR When the ENABLE_MONITOR bit is set to 1, the ADP4000 starts conversions with the ADC and monitors the voltages and temperatures. These bits sets the number of phases turned on during PSI. 00 = 1 Phase enabled during PSI 01 = 2 Phases enabled during PSI 10 = 3 Phases enabled during PSI 11 = 1 Phase enabled during PSI PMBus Timeout Enable. When the PMB_TO_EN bit is set to 1, the PMBus Timeout feature is enabled. In this state if, at any point during an PMBus transaction involving the ADP4000, activity ceases for more than 35 ms, the ADP4000 assumes the bus is locked and releases the bus. This allows the ADP4000 to be used with SMBus controllers that cannot handle SMBus timeouts (Lockable). Bit Name 6:4 Phase Enable Bits 3 VID_EN When the VID_EN bit is set to 1, the VID code in the VOUT_COMMAND register sets the output voltage. When VID_EN is set to 0, the output voltage follows the VID input pins. 2 LOOP_EN When the LOOP_EN bit is set to 1 in both registers, the control loop test function is enabled. This allows measurement of the control loop AC gain and phase response with appropriate instrumentation. The control loop signal insertion pin is IMON. The control loop output pin is COMP. http://onsemi.com 33 Description 000 = Phase 1 001 = Phase 2 010 = Phase 3 011 = Phase 4 100 = Phase 5 101 = Phase 6 All other codes = Phase 6 ADP4000 Cmd Code R/W Default Description # Byte Comment 1 CLIM_EN When CLIM_EN is set to 1, the current--limit time out latchoff functions normally. When this bit is set to 0 in both registers, the current--limit latchoff is disabled. In this state, the part can be in current--limit indefinitely. 0 Reserved Reserved 0xD3 R/W 0x52 VR Config 1B 1 This register is for security reasons. It has the same format as register 0xD2. Bits need to be set in both registers for the function to take effect. 0xD4 R/W 0x03 Ton Delay 1 This resister sets TD1, TD3 and TD5 delays for the soft--start sequence. The current--limit latchoff timer is 4 times the programmed delay time. 000 = 0.5 ms 001 = 1 ms 010 = 1.5 ms 011 = 2 ms = default 100 = 2.5 ms 101 = 3 ms 110 = 3.5 ms 111 = 4 ms 0xD5 R/W 0x02 Ton Rise 1 This register sets the soft--start voltage slew rate, and hence TD2 and TD4, of the soft--start sequence. 000 = 0.1 V/ms 001 = 0.3 V/ms 010 = 0.5 V/ms = default 011 = 0.7 V/ms 100 = 0.9 V/ms 101 = 1.1 V/ms 110 = 1.3 V/ms 111 = 1.5 V/ms 0xD6 R/W 0x01 Ton Transition 1 This register sets the slew rate during a dynamic VID. 000 = 1 V/ms 001 = 3 V/ms = default 010 = 5 V/ms 011 = 7 V/ms 100 = 9 V/ms 101 = 11 V/ms 110 = 13 V/ms 111 = 15 V/ms 0xD7 R 0x00 VSENSE2 Voltage 2 This is a 16 bit value that reports back the voltage on the VSENSE2 Pin. Can be configured to measure the input Voltage Current. 16 Bit Value between 0 and 2.0 V. Voltage is reported using Linear Mode. 0xD8 R 0x00 EN/VTT Voltage 2 This is a 16 bit value that reports back the voltage on the VTT Pin. Voltage is reported using Linear Mode. 0xDA R 0x00 VMON Voltage 2 This is a 16 bit value that reports back the voltage measured between FB and FBRTN. Voltage is reported using Linear Mode. 0xDB R/W 0x00 VOUT_TRIM 1 Offset Command Code for VOUT, max ±200 mV. 0xDC R/W 0x00 VOUT_CAL 1 Offset Command Code for VOUT, max ±200 mV. 0xDE R/W 0x10 Load Line Calibration 1 This value sets the internal load line attenuation DAC calibration value. The maximum load line is controlled externally by setting the gain of the current sense amplifier as explained in the applications section. This maximum load line can then be adjusted from 100% to 0% in 30 steps. Each LSB represents a 3.33% change in the load line. 00000 = No Load Line 10000 = 50% of external load line 11111 = 100% of external Load Line 0xDF R/W 0x00 Load Line Set 1 This value sets the internal load line attenuation DAC value. The maximum load line is controlled externally by setting the gain of the current sense amplifier as explained in the applications section. This maximum load line can then be adjusted from 100% to 0% in 30 steps. Each LSB represents a 3.33% change in the load line. 00000 = No Load Line 10000 = 50% of external load line 11111 = 100% of external Load Line http://onsemi.com 34 ADP4000 Cmd Code R/W Default Description # Byte Comment 0xE0 R/W 0x00 PWRGD Hi Threshold 1 This value sets the PWRGD Hi Threshold and the CROWBAR Threshold: Code = 00, PWRGD HI = 300 mV (default) Code = 01, PWRGD HI = 250 mV Code = 10, PWRGD HI = 200 mV Code = 11, PWRGD HI = 150 mV 0xE1 R/W 0x00 PWRGD Lo Threshold 1 This value sets the PWRGD Lo Threshold: Code = 000, PWRGD Lo = -500 mV (default) Code = 001, PWRGD Lo = -450 mV Code = 010, PWRGD Lo = -400 mV Code = 011, PWRGD Lo = -350 mV Code = 100, PWRGD Lo = -300 mV Code = 101, PWRGD Lo = -250 mV Code = 110, PWRGD Lo = -200 mV Code = 111, PWRGD Lo = -150 mV 0xE2 R/W 0x10 Current--Limit Threshold 1 This value sets the internal current--limit adjust value. The default current--limit is programmed using a resistor to ground on the LIMIT pin. The value of this register adjusts this value by a percentage between 50% and 146.7%. Each LSB represents a 3.33% change in the threshold. 11111 = 146.7% of external current--limit 10000 = 100% of external current--limit (default) 00000 = 50% of external current--limit 0xE3 R/W 0x10 Phase Bal SW1 1 These values adjust the gain of the internal phase balance amplifiers. The nominal gain is set to 5. These registers can adjust the gain by ±25% from 3.75 to 6.25. Code = 00000, Gain of 3.75 Code = 10000, Gain of 5 (default) Code = 11111, Gain of 6.25 0xE4 R/W 0x10 Phase Bal SW2 1 These values adjust the gain of the internal phase balance amplifiers. The nominal gain is set to 5. These registers can adjust the gain by ±25% from 3.75 to 6.25. Code = 00000, Gain of 3.75 Code = 10000, Gain of 5 (default) Code = 11111, Gain of 6.25 0xE5 R/W 0x10 Phase Bal SW3 1 These values adjust the gain of the internal phase balance amplifiers. The nominal gain is set to 5. These registers can adjust the gain by ±25% from 3.75 to 6.25. Code = 00000, Gain of 3.75 Code = 10000, Gain of 5 (default) Code = 11111, Gain of 6.25 0xE6 R/W 0x10 Phase Bal SW4 1 These values adjust the gain of the internal phase balance amplifiers. The nominal gain is set to 5. These registers can adjust the gain by ±25% from 3.75 to 6.25. Code = 00000, Gain of 3.75 Code = 10000, Gain of 5 (default) Code = 11111, Gain of 6.25 0xE7 R/W 0x10 Phase Bal SW5 1 These values adjust the gain of the internal phase balance amplifiers. The nominal gain is set to 5. These registers can adjust the gain by ±25% from 3.75 to 6.25. Code = 00000, Gain of 3.75 Code = 10000, Gain of 5 (default) Code = 11111, Gain of 6.25 0xE8 R/W 0x10 Phase Bal SW6 1 These values adjust the gain of the internal phase balance amplifiers. The nominal gain is set to 5. These registers can adjust the gain by ±25% from 3.75 to 6.25. Code = 00000, Gain of 3.75 Code = 10000, Gain of 5 (default) Code = 11111, Gain of 6.25 0xEE R/W 0x0050 VRHOT RESET LIMIT 2 This is the temperature below which the VTHOT will de--assert. 0xEF R/W 0x0002 VSENSE2 High Limit 2 VSENSE2 voltage high limit. 0xF0 R/W 0x0000 VSENSE2 Low Limit 2 VSENSE2 voltage low limit. 0xF1 R/W 0x0002 VSENSE2 FAULT Limit 2 VSENSE2 voltage FAULT limit. 0xF5 R/W 0x0002 VMON FAULT Limit 2 VMON FAULT Limit. http://onsemi.com 35 ADP4000 Cmd Code R/W Default Description 0xF6 R/W 0x0002 VMON Warn Limit 2 VMON Warn Limit. 0xF7 R/W 0x07CE TTSENSE Gain 2 Gain information used to convert TTSENSE Voltage to temperature. 0xF8 R/W 0x007B TTSENSE Offset 2 Offset information used to convert TTSENSE Voltage to temperature. 0xF9 R/W 0x00 Mask ALERT 1 Bit Name 7 Mask VOUT Masks any ALERT caused by bits in Status VOUT Register. 6 Mask IOUT Masks any ALERT caused by bits in Status IOUT Register. 5 Mask Input Masks any ALERT caused by bits in Status Input Register. 4 Mask Temperature Masks any ALERT caused by bits in Status Temperature Register. 3 Mask CML Masks any ALERT caused by bits in Status CML Register. 2 VMON Masks any ALERT caused by VMON exceeding its high or low limit. 1 VSENSE2 Masks any ALERT caused by VSENSE2 exceeding its high or low limit. 0 Mask POUT Bit Name 7 Mask VOUT Masks any FAULT caused by bits in Status VOUT Register. 6 Mask IOUT Masks any FAULT caused by bits in Status IOUT Register. 5 Mask Input Masks any FAULT caused by bits in Status Input Register. 4 Mask Temperature Masks any FAULT caused by bits in Status Temperature Register. 3 Mask CML Masks any FAULT caused by bits in Status CML Register. 2 VMON Masks any FAULT caused by VMON exceeding its high or low limit. 1 VSENSE2 0 Mask POUT 0xFA 0xFB 0xFC R/W R/W R 0x00 0x00 0x00 Mask FAULT General Status Phase Status # Byte 1 1 1 Comment Bit Name 7 FAULT 6 ALERT 5 POWER--GOOD 4 RDY Description Masks any ALERT caused by POUT exceeding its programmed limit. Description Masks any FAULT caused by VSENSE2 exceeding its high or low limit. Masks any FAULT caused by POUT exceeding its programmed limit. Description Replaced by Bit 3 of the Status Word Command. Bit Name 7 Phase 6 This bit is set to 1 when Phase 6 is enabled. 6 Phase 5 This bit is set to 1 when Phase 5 is enabled. 5 Phase 4 This bit is set to 1 when Phase 4 is enabled. 4 Phase 3 This bit is set to 1 when Phase 3 is enabled. 3 Phase 2 This bit is set to 1 when Phase 2 is enabled. http://onsemi.com 36 Description ADP4000 PACKAGE DIMENSIONS LFCSP48 7x7, 0.5P CASE 932AD--01 ISSUE O D A NOTES: 1. DIMENSIONING AND TOLERANCING PER ASME Y14.5M, 1994. 2. CONTROLLING DIMENSIONS: MILLIMETERS. 3. DIMENSION b APPLIES TO PLATED TERMINAL AND IS MEASURED BETWEEN 0.15 AND 0.30mm FROM THE TERMINAL TIP. 4. COPLANARITY APPLIES TO THE EXPOSED PAD AS WELL AS THE TERMINALS. B D1 PIN ONE REFERENCE E1 E DIM A A1 A3 b D D1 D2 E E1 E2 e H K L M 0.20 C TOP VIEW 0.20 C H (A3) 0.10 C A NOTE 4 0.08 C SIDE VIEW A1 C 4X M D2 K 4X MILLIMETERS MIN MAX 0.80 1.00 0.00 0.05 0.20 REF 0.18 0.30 7.00 BSC 6.75 BSC 4.95 5.25 7.00 BSC 6.75 BSC 4.95 5.25 0.50 BSC -----12 ° 0.25 -----0.30 0.50 -----0.60 SEATING PLANE SOLDERING FOOTPRINT* M 7.30 13 25 5.14 1 E2 PIN 1 INDICATOR 48X L 5.14 1 48 e 37 48X BOTTOM VIEW 48X 0.63 b 0.10 C A B 0.05 C 7.30 PACKAGE OUTLINE NOTE 3 48X 0.50 PITCH 0.28 DIMENSIONS: MILLIMETERS *For additional information on our Pb--Free strategy and solder details, please download the ON Semiconductor Soldering a Mounting Techniques Reference Manual, SOLDERRM/D. FlexMode is a trademark of Analog Devices, Inc. ON Semiconductor and are registered trademarks of Semiconductor Components Industries, LLC (SCILLC). SCILLC reserves the right to make changes without further notice to any products herein. SCILLC makes no warranty, representation or guarantee regarding the suitability of its products for any particular purpose, nor does SCILLC assume any liability arising out of the application or use of any product or circuit, and specifically disclaims any and all liability, including without limitation special, consequential or incidental damages. “Typical” parameters which may be provided in SCILLC data sheets and/or specifications can and do vary in different applications and actual performance may vary over time. All operating parameters, including “Typicals” must be validated for each customer application by customer’s technical experts. SCILLC does not convey any license under its patent rights nor the rights of others. SCILLC products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or other applications intended to support or sustain life, or for any other application in which the failure of the SCILLC product could create a situation where personal injury or death may occur. Should Buyer purchase or use SCILLC products for any such unintended or unauthorized application, Buyer shall indemnify and hold SCILLC and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that SCILLC was negligent regarding the design or manufacture of the part. SCILLC is an Equal Opportunity/Affirmative Action Employer. This literature is subject to all applicable copyright laws and is not for resale in any manner. PUBLICATION ORDERING INFORMATION LITERATURE FULFILLMENT: Literature Distribution Center for ON Semiconductor P.O. Box 5163, Denver, Colorado 80217 USA Phone: 303--675--2175 or 800--344--3860 Toll Free USA/Canada Fax: 303--675--2176 or 800--344--3867 Toll Free USA/Canada Email: [email protected] N. American Technical Support: 800--282--9855 Toll Free USA/Canada Europe, Middle East and Africa Technical Support: Phone: 421 33 790 2910 Japan Customer Focus Center Phone: 81--3--5773--3850 http://onsemi.com 37 ON Semiconductor Website: www.onsemi.com Order Literature: http://www.onsemi.com/orderlit For additional information, please contact your local Sales Representative ADP4000/D