ETC DPM40

DPM 40
3½ Digit LED Module
A compact low-cost LED module ideally suited for applications where a bright display under all conditions is required. The DPM 40 is fitted
with high efficiency LEDs and supplied with a filter and bezel to give a high contrast display. The small size and low cost of the unit makes it
11mm (0.43“)Digit Height
Programmable Decimal Points
Auto-zero
Auto-polarity
200mV d.c. Full Scale Reading (F.S.R.)
Display Hold
SCALING
Stock Number
Two resistors Ra and Rb may be fitted in order to alter
the full scale reading (F.S.R.) of the meter - see table.
The meter will need re-calibration .
Required F.S.R.
2V
20V
200V
2kV
200µA
2mA
20mA
Note
Note
Note
Note
Ra
Specification
Accuracy (overall error) *
Linearity
Sample rate
Operating temperature range
Temperature stability
Supply voltage
Supply current
Input leakage current (Vin = 0V)
Rb
910k
1M
1M
1M
LINK
LINK
LINK
100k
10k
1k
100R
1k
100R
10R
Min.
Typ.
Max.
0.05
0.1
±1
3
0
4.5
50
150
5
100
110
5.5
200
pA
Unit
% (±1 count)
count
samples/sec
°C
ppm/°C
V
mA
* To ensure maximum accuracy, re-calibrate periodically.
NOTE
Ensure that link across Ra is OPEN.
DIMENSIONS All dimensions in mm (inches)
a
72 (2.83)
b
c
36 (1.30)
a. 4.0 (0.16)
b. 12.0 (0.47)
c. 8.5 (0.33)
18 (0.71)
Viewing Area
45.5 (1.79)
Panel cut-out 68 x 33 (2.68 x 1.30)
62 (2.44)
Ø2.2
(0.09)
+5V
COM
IN HI
IN LO
0V
30.5 (1.20)
68 (2.68)
27 (1.05)
Ra
DP1
DP2
DP3
CLOCK
DP COM
33 (1.30)
24 (0.94)
Rb
SCALING RESISTORS
P.O. Box 897, Windham, NH 03087
(603) 893-0886 (800) 821-0023 FAX (603) 898-6820
PIN FUNCTIONS
A.
B.
C.
D.
DP1
DP2
DP3
CLOCK/
HOLD
E. DP COM
1. +5V
2. COM
199.9
19.99
1.999
Connect to 0V to hold display reading. Leave open for normal operation.
3. IN HI
4. IN LO
5. 0V
Connect to Pin A, B or C to select required DP.
Positive power supply input.
The ground for the analogue section of the converter, held actively at 2.8V (nom) below +5V. This pin is for use only when the module
is used with a fully floating supply. It should on no account be connected to any other terminations or circuitry except as specified in
the relevant operating modes.
Positive measuring input.
Analogue inputs must be no closer than 1V to the positive supply or lower than 1.5V below 0V.
Negative measuring input.
Negative power supply input.
SAFETY
To comply with the Low Voltage Directive (LVD 93/68/EEC), input voltages to the module’s pins must not exceed 60Vdc. If voltages to the
measuring inputs do exceed 60Vdc, then fit scaling resistors externally to the module. The user must ensure that the incorporation of the DPM
into the user’s equipment conforms to the relevant sections of BS EN 61010 (Safety Requirements for Electrical Equipment for Measuring,
Control and Laboratory Use).
VARIOUS OPERATING MODES
INPUT
VOLTAGE
+
3
-
4
1
+5V
+5V
+5V
IIN
1
3
IN HI
IN LO
6R2
220k
5k
0V
SET
ZERO
IOUT
5
+5V
IN HI
4
IN LO
2 COM
0V
5
0V
0V
Operation with input referenced to panel
3
4
R
2
R= 0.2
IFSR
1
+5V
+5V
IN HI
INPUT
VOLTAGE
IN LO
+
3
-
4
2
COM
0V
1
+5V
+5V
IN HI
IN LO
COM
0V
5
5
0V
0V
Operation with input floating with respect to
power supply.
Specifications liable to change without prior warning
DPM 40
Issue 3
August/1997
M.C.