User's Guide EasyView Light Meter with Memory Model EA33 Introduction Congratulations on your purchase of the Extech EA33 EasyView Light Meter which measures light level (illuminance). This device measures up to 99,990 Fc and 999,990 Lux and stores up to 50 readings for easy recall. Careful use of this meter will provide years of reliable service. Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies on sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website at www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. Specifications Units Ranges and Resolution Accuracy Lux 99.99, 999.9, 9999 ± (3% rdg + 0.5%FS) Foot candles 99990 ± (3% rdg + 5 digits) 999900 ± (3% rdg + 0.5%FS) 9.999, 99.99, 999.9 ± (3% rdg + 0.5%FS) 9999 ± (3% rdg + 5 digits) 99990 ± (3% rdg + 0.5%FS) Note: Calibrated to a standard incandescent lamp at color temperature of 2856K Display Multi-function LCD with a maximum display of 999900 Ranging Autoranging over five ranges Over range indication LCD displays ‘OL’ Spectral response CIE photopic (CIE human eye response curve) Spectral accuracy Cosine response Vλ function (f’1 ≤6%) f’2 ≤2%; Cosine corrected for angular incidence of light Measurement Repeatability ±2% Temperature coefficient ±0.1% per C o Sampling rate 5 times per second Photo detector Silicon photo-diode with spectral response filter Operating conditions Temperature: 32 to 104 F (0 to 40 C); Humidity: < 80%RH Storage conditions o o o o Temperature: 14 to 140 F (-10 to 50 C); Humidity: < 80%RH Meter Dimensions 5.91 x 2.8 x 1.4" (150 x 72 x 35mm) Detector Dimensions 3.6 x 2.4 x 1.5” (92 x 60 x 29mm) Weight Approx. 11.3 oz. (320g) with battery Sensor lead length 5’ (150cm) Low battery indication Battery symbol appears on the LCD Power supply Six (6) ‘AAA’ cells Battery life 200 hours (approx.) 2 EA33 V2.0 06/06 Meter Description 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. Light measurement display Timer display TIME button HOLD button Unit of measure button (Fc/lux) Enter button Luminous Intensity (cd) / Comparator button READ / Right arrow button Average reading tally display Power ON/OFF button Set button Average button Relative / Percent button Light sensor Left arrow / Memory button Up / Down arrow buttons Display 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. Relative Mode Comparator Mode Average Data Hold % Relative Candela % Relative fc/lx-hours Integral Illuminance Stray light measurement Time Hold measurement ft/m luminance intensity distance Day-Hour minute-seconds Memory Read Memory location Average Reading tally display Integration cycles Low battery Elapsed time indicator 1 3 2 4 5 6 7 8 9 10 18 17 16 15 14 11 13 12 3 EA33 V2.0 06/06 Basic Operation 1. With the sensor cover in place, press the will perform a short self-test. button to turn the meter on. The meter 2. Remove the sensor’s protective cap and place the sensor in the area to be measured. 3. Press the lux / fc button to select the desired units of measure. 4. Read the light level on the display. If the measurement is out of range, an “OL” indication will appear. 5. When the meter is turned on, the elapsed timer starts. The elapsed timer shows days/hours or minutes/seconds. Use the TIME button to toggle the view between minutes/seconds (M-S) and days/hours (D-H). Operation Modes In addition to the normal mode of operation where light level is measured, there are 5 special modes, listed below. Each mode is explained in the subsequent sections of this manual. The SET button is used to access the modes. The number on the lower left of the LCD (after the SET button is pressed) represents the mode currently selected. Use the down arrow key to scroll to the desired mode. Programming modes Mode Name of mode Description SEt 01 Stray+ Light Cancels out stray light from light under test SEt 02 Time - Hold Meter measures while timer counts down. Reading is held on LCD when counter = 0. SEt 03 rtC Set the day and time for internal clock SEt 04 Int Lumen-seconds, lux-hour, and fc-hour measurements SEt 05 COMP Measurements are compared to high and low limits. MODE 1 - Stray Light Inhibit This feature allows the user to measure light from one source while automatically factoring out the light from a secondary (stray) unwanted source. 1. Turn on the desired light source and face the meter’s sensor towards this source (the stray light source should be on also). 2. Press the SET key; ‘SEt’ and ‘STRAY + LIGHT ‘will appear at the center of the LCD and ‘01’ will appear on the lower left of the LCD (see diagram). 3. Press the ENTER key ( ). The measurement at this point consists of the primary AND the stray light sources (LIGHT + STRAY). 4. Press ENTER to store this value. STRAY will appear on the display 5. Turn off the primary light source. 6. Press the ENTER key again to store only the stray light source. 7. The meter will now compute and display the light level for only the desired (primary) light source. ‘LIGHT’ and ‘DH’ (Data Hold) will also appear on the display. 8. Press the ENTER key to exit this mode. 4 EA33 V2.0 06/06 MODE 2 – Elapsed Timer with Hold In this mode, measurements are made while the countdown timer is running. When the timer reaches zero, the last measurement is held on the display (see diagram). 1. Press the SET key; ‘SEt 01’ will display. 2. Press the down arrow key to change to the ‘SEt 02’ parameter. ‘TIME-HOLD’ will appear on the display. 3. Press the ENTER key to call up the timer. 4. Use the up/down arrow keys to set the desired seconds. 5. Press the ENTER key to program the number of minutes. 6. Use the up/down arrow keys to set the minutes. 7. Press the ENTER key to start the countdown timer. When the timer counts down, the last reading will be held on the display. 8. Press the ENTER key to exit this mode. MODE 3 - Real Time Clock Setting 1. Press the SET key; ‘SEt01’ will display. 2. Press the down arrow key twice to select the ‘SEt03’ parameter. ‘ftc’ will appear on the lower right of the LCD. 3. Press the ENTER key to enter the edit mode for ‘seconds’. 4. Use the up/down arrow key to program the ‘seconds’. 5. Repeat the previous two steps for the ‘minutes’, ‘hours’, and ‘day’ settings. 6. Press the ENTER key when finished. 7. Use the TIME key to toggle between minutes-seconds (m-s) and day-hour (D-H) views. MODE 4 - Integral Illuminance Mode Integral Illuminance is a luminous energy measurement based on the rate of flow of flux (expressed in lumen-seconds). The Model EA33 can also measure any photometric quantity on a time dependent basis. For example, the illuminance could be integrated over time to yield lux-hours (lx-h) or foot candle-hours (fc-h). 1. Press the SET key; ‘SEt 01’ will appear on the display. 2. Press the down arrow key three times to select the ‘SEt 04’ mode. ‘int’ will also appear on the LCD. 3. Press the ENTER key to start the Integral Illuminance measurement. The meter will set the first measurement as a reference. The ‘lx-h’ or ‘fc-h’ display icon will appear and the timer will start (the cycle number appears on the lower left of the LCD). 4. If measurements exceed the reference value, the display will freeze and the ‘+’ symbol will appear. Note that the timer will also halt. 5. The maximum indication of integral illuminance is 999999. When this maximum is exceeded, the integration number (Cycle no. at lower left of LCD) can be checked. The maximum number of integration cycles is 99. 6. Press the ENTER key to exit this mode of operation. 5 EA33 V2.0 06/06 MODE 5 - Comparator Mode In this mode the meter compares its measurements to one HIGH and one LOW limit. When the high limit is exceeded, the plus sign appears on the LCD. When the measurement falls below the low limit, the negative sign appears on the LCD. 1. Press the SET key; ‘SEt01’ will appear on the display. 2. Press the down arrow key four times to select the ‘SEt05’ parameter. ‘COMP’ appears. 3. Press the ENTER key to enter the Comparator setting mode. 4. Press the down arrow key to select the desired unit of measure (Lux or Fc). 5. Press ENTER to begin setting the measurement range. 6. Use the down arrow to select the desired range. 7. Press the ENTER key to begin setting the Comparator HIGH limit value. The ‘+’ symbol will appear. 8. Use the up/down arrow keys to set the high limit value. 9. Press the ENTER key to begin setting the Comparator LOW limit value. The minus symbol will appear. 10. Use the up/down arrow keys to set the desired LOW limit value. 11. Press ENTER to complete the Comparator setup. 12. Press and hold the cd/COMP key for three seconds to activate the Comparator. 13. Now if a measurement exceeds the high limit, the plus sign will appear. If the low limit is exceeded, the minus sign will appear. An audible beep will sound when a limit has been reached. 14. Press the ENTER key to exit the Comparator mode. 99-Point Averaging Illuminance is the amount of visible light incident upon a specific surface area. Since the EA33 sensor area is small, the Average Mode can be used to measure the illuminance of larger surface areas; to accomplish this, up to 99 points can be averaged. 1. Press the AVG key. The ‘AVG’ display icon will appear. 2. Press the MEM key to store a reading (up to 99 readings can be averaged). The display at the lower left will keep a running tally of the AVG readings recorded. 3. Press the READ key to perform the average calculation. The average value will be displayed and held on the LCD. 4. Pressing the MEM key at this point allows the meter to continuously average subsequent illuminance readings (the display will only show an average value). 5. Use the READ button to toggle between this continuous Average display and the normal measurement display. 6. Press the ENTER key to exit. 6 EA33 V2.0 06/06 Luminous Intensity Feature Luminous intensity is the measurement of light from a light source at a known distance from the sensor. The unit of measure is candela (cd). 1. Press the cd/COMP key to begin. The annunciator ‘m’ for meters (for lux measurement) or ‘ft’ for feet (for Fc measurement) will appear. 2. Use the up/down arrow keys to set the distance from the light source to the light sensor. The distance range is 0.01 to 9.99 meters or feet. 3. The measurement must be made in a dark room or in a room with no stray light. 4. The distance between the sensor and light source must be at least 10 times the size of the light source. 5. Press the ENTER key to perform the luminous intensity measurement. The ‘cd’ (for candela) units icon will appear along with the reading. 6. Press the ENTER key again to exit. Data Record/Recall MEMORY CLEAR 1. Turn off the meter. 2. Press and hold the MEM key while turning on the meter. Release the MEM key when the display reads ‘CLr’ indicating that the memory banks have been cleared (erased). MANUAL DATA RECORD 1. Each time the MEM key is pressed with the meter turned on, a data record is recorded. The display will show ‘M’ and an audible tone will sound. 2. The counter on the lower left of the LCD will show the number of stored readings. 3. The total memory size is 50 records. READING STORED RECORDS 1. Press the READ key to enter the memory recall mode. The display will show ‘R’ and the address number for the displayed data point. 2. Use the up/down arrow keys to scroll through the stored readings. 3. Press the ENTER key to exit this mode of operation. AUTO POWER OFF Feature To conserve battery life, the EA33 automatically turns off after several minutes. To defeat this feature: 1. Turn the meter OFF. 2. Press and hold the HOLD key while turning the meter ON. 3. The AUTO POWER OFF feature will now be disabled. 4. Note that AUTO POWER OFF is re-enabled each time the meter is turned on. 5. Also note that AUTO POWER OFF is always disabled in the Integral Illuminance mode. 7 EA33 V2.0 06/06 Maintenance Cleaning and storage 1. The white plastic sensor dome should be cleaned with a damp cloth when necessary. 2. Store the meter in an area with moderate temperature and humidity (refer to the operating and storage range in the specifications chart earlier in this manual). Battery Replacement When the battery power falls low, the battery symbol will appear on the lower left-hand side of the LCD. Replace the six (6) 1.5 ‘AAA’ batteries by removing the rear (center) battery compartment screw and accessing the battery compartment. Observe polarity when placing the batteries in the compartment. Ensure that the compartment cover is securely fastened when finished. Calibration and Repair Services Extech offers complete repair and calibration services for all of the products we sell. For periodic calibration, NIST certification or repair of this Extech product, call customer service for details on services available. Extech recommends that calibration be performed on an annual basis to ensure calibration integrity. Support line (781) 890-7440 Technical support: Extension 200; E-mail: [email protected] Repair & Returns: Extension 210; E-mail: [email protected] Product specifications subject to change without notice For the latest version of this User’s Guide, Software updates, and other up-to-the-minute product information, visit our website: www.extech.com Copyright © 2006 Extech Instruments Corporation. All rights reserved including the right of reproduction in whole or in part in any form. 8 EA33 V2.0 06/06 Appendix Typical Light Levels Lux Foot Candles 20-75 2-7 Lux Foot Candles Emergency Stairs, Warehouse 100-150 10-15 Washing Factories Home 75-150 7-15 Exit/Entrance Passages 150-200 15-20 Recreational Activities 150-300 15-30 Packing Work 200-300 20-30 Drawing Room, Table 300-750 30-75 Visual Work: Production Line 300-500 30-50 Makeup 750-1,500 75-150 Typesetting: Inspection Work 500-1,500 50-150 Reading, Study 1,500-3,000 150-300 Electronic Assembly, Drafting 1,000-2,000 100-200 Sewing 75-100 7-10 Indoor Emergency Stairs 75-150 7-15 Corridor Stairs 100-200 10-20 Corridor Stairs 150-300 15-30 Entrance, Wash Room 200-750 20-75 Conference, Reception Room 300-750 30-75 Cooking Room, Dining Table 750-1,500 75-150 Clerical Work 750-1,500 75-150 Show Window 30-75 3-7 Emergency Stairs Office Restaurant 1,500-2,000 150-2000 Typing, Drafting Store Hospital 75-150 7-15 Indoors 150-200 15-20 Corridor/Stairs 75-100 7-10 Stairs 200-300 20-30 Reception 100-150 10-15 Sick Room, Warehouse 300-500 30-50 Display Stand 150-200 15-20 Waiting Room 500-750 50-75 Elevator 200-750 20-75 Medical Exam Room 750-1,500 75-150 Show Window, Packing Table 750-1,500 75-150 Operating Room 1,500-3,000 150-300 Storefront, Show Window 5,000-10,000 500-1000 Eye Inspection Spectral Sensitivity 1.2 1.2 1 0.8 0.8 0.6 0.6 0.4 0.4 0.2 0.2 Light Meter CIE 780 760 740 720 700 680 660 640 620 600 580 560 540 520 500 480 460 440 420 0 400 0 380 Relative Sensitivity (%) 1 Wavelength in Nonometers 9 EA33 V2.0 06/06