MURATA EB-HTB

®
®
DMS-EB-HTB
Actual Size
Order online at www.datel.com
Features
• Accepts inputs from user-supplied
solid-state temperature sensors
• Available in °C or °F output readings
• 6-wire screw-type terminal block
• Measures temperatures from
–55 to +150°C (–67 to +199.9°F)
• Use with DMS-30PC/LCD-0 meters
12
1
R6
R1
PROBE
CAL.
R4
REF.
CAL
R3
R5
R2
High-Accuracy
Temperature Sensor Boards
DMS-30PC/LCD-0 Meters
U1
TB1
Description: The DMS-EB-HTB Application Boards accept inputs from usersupplied, AD590 solid-state temperature sensors. The boards can be used with
any of DATEL's ±200mV, 5V-powered DMS-30PC/LCD-0 Series, 3½ Digit, LED/
LCD Display, Digital Panel Voltmeters — although better performance can be
achieved with either LCD or low-power LED models. This meter/board combination
provides extremely accurate (±0.3°C) temperature measurements over the range
of –55 to +150°C(with DMS-EB-HTBC) or –67 to +199.9°F (DMS-EB-HTBF).
Individual reference-adjust and probe-adjust potentiometers allow for "fine tuning"
the AD590 output to precisely match the selected meter. A 6-wire, screw-type
terminal block provides for quick, reliable, signal and power connections.
Calibration: R4 (Reference Adjust) is factory-calibrated to +459.8mV for °F
and +273.2mV for °C (do not readjust). This measurement is taken between TB1
(pin 6) and pin 12 of the DMS-30PC/LCD-0. R1 (Probe Adjust) requires customer
adjustment since every sensor has a slightly different zero offset. Calibration is
simple: connect the sensor leads to TB1 and adjust R1 until the DMS-30's display
matches a selected reference temperature indicator.
1
R6
3.9k
12
Functional Specifications
(TA = 25°C, VCC = +5V)
+5V SUPPLY
+
R3
Measurement Range:
DMS-EB-HTBC
DMS-EB-HTBF
U1
1.23V
REF.
11
–55 to +150°C
–67 to +199.9°F
Sensor Type
AD590 active linear device
Accuracy:
Typical
Maximum
±0.3°C (or °F)
±1.0°C (or °F)
Operating Voltage Range
+5V (±10%)
Input Current (Board only):
Typical
Maximum
+0.8mA
+1.0mA
Sensor Lead Length
3 feet, maximum
1
(–) INPUT LO
(+) INPUT HI
PROBE
CAL.
–
R1
200
10
REF.
CAL.
2
R4
2k
3
5V RETURN
9
4
R2
R5
DP 3
5
8
REF. OUT
6
7
REF. IN
TB1
Operating Temperature Range 0 to +60°C
Storage Temperature Range
–20 to +75°C
Humidity (non-condensing)
0 to 95%,
Dimensions
2.02" (51.31mm)L
0.83"(21.08mm)W
DMS-EB-HTBF
DMS-BZL1
DMS-BZL2
Temperature Probe
(user supplied)
2
–
5
+
+5V
SUPPLY
6
5V
RETURN
AD590
R2
R3
R5
HTBF
1.74k
6.65k
4.53k
HTBC
953
8.66k
2.74k
Figure 1. DMS-EB-HTB Schematic Diagram
Ordering Information
DMS-EB-HTBC
1
High-accuracy temperature
probe board, Celsius
High-accuracy temperature
probe board, Fahrenheit
Bezel assembly
Bezel assembly with sealing gasket
DS-0399B
03/01
DATEL, Inc., Mansfield, MA 02048 (USA) • Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 • Email: [email protected] • Internet: www.datel.com
DATEL makes no representation that the use of its products in the circuits described herein, or the use of other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein
do not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without notice. The DATEL logo is a registered DATEL, Inc. trademark.