MURATA EB-DCDC

DMS-EB-DC/DC
DC/DC Converter and Isolation Board for
DMS-30PC/LCD Meters
FEATURES
N
Provide isolated +5V power for DMS-30 Series meters
N
750V minimum isolation
N
Ideal for high-side dc ammeters shunts
N
Provisions for +12V operation
N
Includes all the features of the standard DMS-EB board
N
Use with all DMS-30PC and DMS-30LCD
(5V models only)
N
–25 to +60°C operating temperature range
Description: The DMS-EB-DC/DC Application Board provides isolated +5V power for
DATEL's DMS-30PC/LCD Series, 3½ Digit, LED/LCD Display, Digital Panel Voltmeters. This
add-on board is ideal for applications requiring isolation (up to 750V) between the input
signal and the meter's +5V supply.
Features: The DMS-EB-DC/DC is an excellent choice for dc ammeter applications.
These ammeters typically have the current shunt located on the positive side of the power
supply — a condition which usually exceeds the meter's common mode voltage limit.
Input-to-output isolation is required if the power source being measured also powers the
DMS-30. DATEL's new Panel Meter Catalog has a detailed application note on dc ammeters.
Applications: The DMS-EB-DC/DC incorporates all standard features of the DMS-EB
board; the only exception being the smaller allowable range of power supply voltage when
using the LM7805 3-terminal regulator. Use the DMS-EB-DC/DC with any DMS-30PC meter
or DMS-30LCD meter (5V-powered models only).
+7.5-18V Operation (Optional): Open SG4 and install U2 (LM7805CT) with its metal
tab adjacent to U1. Applications requiring a lower dropout voltage should consider the
LM2931T-5. Exceeding the
C4
12
1
R1
SG14
R2
allowable regulator input voltage
SG10
C3
C1
SG11 SG9 SG8 SG7
ranges (see Functional SpecificaSG6 SG5
U1
tions) will cause device overR3
R6
C4
heating! As is the case when
U2
specifying any electronic power
SG2
SG4
component, be sure to consult all
J1
SG12
R5
R4
SG3 SG1
1 2 3 4 5 6
applicable manufacturer's data
sheets.
Functional Specifications
TA = 25°C, VCC = +5V
+5V (±5%)
Input Current:
Typical
Maximum
+150mA
+250mA
Regulator Input Voltage Range
(LM7805CT):
DMS-30PC-X-XS
DMS-30PC-X-RL
DMS-30LCD-X-5(B)
+7.5 to +9.5Vdc
+7.5 to +18Vdc
+7.5 to +18Vdc
Output Voltage
+5V (±5%)
Isolation
750V, minimum
Operating Temperature
0 to +60°C
Storage Temperature
– 20 to +75°C
Dimensions:
2.02" (51.31mm)L
0.83" (21.08mm)W
Humidity (Non-condensing)
0 to 95%
SG13
Input Voltage
Ordering Information
DMS-EB-DC/DC
DMS-BZL1
DMS-BZL2
RN-DMS
DC/DC converter board (with mating connector)
Bezel assembly
Bezel assembly with sealing gasket
Resistor accessory kit
For full details go to
www.murata-ps.com/rohs
www.murata-ps.com
Technical enquiries email: [email protected], tel: +1 508 339 3000
MPM_DMS-EB-DCDC.B01 Page 1 of 2
DMS-EB-DC/DC
DC/DC Converter and Isolation Board for
DMS-30PC/LCD Meters
(–) INPUT LO
12
SG14
(+) INPUT HI
ANALOG
COMMON
U1
R2
11
-VIN
R1 SG9
+1.23V
REF. OUT
+
SG10
10
R3 10.5k
R4 2k
9
REF. IN
2
-VOUT
SG7
+5V SUPPLY/
+BATTERY
TEST/
BACKLIGHT
3
5V RETURN/
–BATTERY
+VOUT
SG6
SG11
SG4
C4
0.1μF
50V
SG3
4
DP 3
U2
SG2
8
5
+VIN
R5 50k
SG13
C3
22μF
10V
R6
4.7k
SG8
REF. OUT
1
+VOUT
+VIN
LM7805CT
DP 2
SG1
7
C2
0.22μF
50V
SG5
SG12
6
DP 1
J1
Components are user-supplied
and not part of the standard product
Components are part of the resistor accessory
kit RN-DMS (see Ordering Information).
Open solder gap
1
2
3
4
5
6
Closed solder gap
HI LO TST TST +V –V
(+) (–) IN OUT
GND
Figure 1. DMS-EB-DC/DC Schematic Diagram
USA:
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
Tel: (508) 339-3000 (800) 233-2765 Fax: (508) 339-6356
www.murata-ps.com email: [email protected] ISO 9001 and 14001 REGISTERED
11/26/08
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of other
technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do not imply
the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to change without
notice.
© 2008 Murata Power Solutions, Inc.
www.murata-ps.com
Mansfield (MA), Tel: (508) 339-3000, email: [email protected]
Canada:
Toronto, Tel: (866) 740-1232, email: [email protected]
UK:
Milton Keynes, Tel: +44 (0)1908 615232, email: [email protected]
France:
Montigny Le Bretonneux, Tel: +33 (0)1 34 60 01 01, email: [email protected]
Germany:
München, Tel: +49 (0)89-544334-0, email: [email protected]
Japan:
Tokyo, Tel: 3-3779-1031, email: [email protected]
Osaka, Tel: 6-6354-2025, email: [email protected]
China:
Shanghai, Tel: +86 215 027 3678, email: [email protected]
Guangzhou, Tel: +86 208 221 8066, email: [email protected]
Singapore:
Parkway Centre, Tel: +65 6348 9096, email: [email protected]
Technical enquiries email: [email protected], tel: +1 508 339 3000