MA-COM VF28-65F14-S01

Plug-In Relays
Mini 280 Relays
Catalog 1308028
Revision 03-06
VF28
Powertrain
Systems
Revision 03-05
Chassis
Systems
Safety
Security
Body
Driver
Information
Convenience
Description
Features
- 30 A continuous contact
rating at 85 °C
- Various enclosure options
Typical applications
-
Fuel pump
A/C compressor clutch
Horn
Lighting systems
Car Industry
Please contact Tyco Electronics
for relay application support.
Truck
Industry
Other
Industry
VF28_3d1
Design
Conditions
Various enclosure options (dust cover,
shrouded/weatherproof cover);
optional mounting bracket
All parametric, environmental and
endurance tests are performed
according to EIA Standard RS-407-A
at standard test conditions unless
otherwise noted:
23 °C ambient temperature,
20-50% RH, 29.5 ± 1.0" Hg
(998.9 ±33.9 hPa).
Please also refer to the Application
Recommendations in this catalog
for general precautions.
Weight
Approx. 1.2 oz. (34 g) dust cover
model
Nominal voltage
12 V, 24 V
Terminals
2.8 mm dual in-line quick connect
terminals
Accessories
Connectors see page 191
Disclaimer
All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of
the relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and
to request our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without
notification. All rights of Tyco are reserved.
56
Please observe the disclaimer.
Plug-In Relays
Mini 280 Relays
Catalog 1308028
Revision 03-06
VF28
Revision 03-05
Dimensional drawing
Dust cover with quick connect terminals
VF28-1****
1.12 MAX.
(28.5)
1.12 MAX.
(28.5)
1.004 MAX.
(25.5)
.453 MAX.
(11.5)
.110
(2.8)
.032 ± .001
(.825 ± .035)
ECR2118-M
View of the terminals (bottom view)
.307
(7.8)
.091
(2.3)
85
30
87A
86
87
.319
(8.1)
.638
(16.2)
Shrouded/weatherproof cover with quick connect terminals
VF28-3**** and VF28-6****
.654
(16.6)
.354 ± .024
(9.0 ± 0.6)
+0.02
-.006
+.005
6.65
-.015
.858 ± 0.20
(21.8 ± 0.5)
.262
(
)
.110 ± .018
(2.8 ± 0.45)
1.8 MAX.
(45.8)
.776
(19.7)
.453
(11.5)
.110
(2.80)
.032 ± .001
(.825 ± .035)
View of the terminals (bottom view)
.482 REF.
(12.25)
1.425 MAX.
(36.2)
ECR2119-V
.091
(2.3)
.307
(7.8)
.319
(8.1)
TOLERANCE UNLESS
OTHERWISE NOTED:
2 DECIMAL: ± .004
( ± 0.1)
1 DECIMAL: ± .006
( ± 0.15)
.500 ± .016
(12.7 ± 0.4)
.638
(16.2)
57
Please observe the disclaimer.
Plug-In Relays
Mini 280 Relays
Catalog 1308028
Revision 03-06
VF28
Revision 03-05
Contact data
Make contact/
Form A
Contact configuration
Changeover contact/
Form C
Circuit symbol
12 V
30 A
AgNi0.15
Rated voltage
Rated curent at 85 °C
Contact material
Max. switching voltage/power
Max. switching current1)
On2)
Off
Min. recommended load3)
Voltage drop A (initial)
NO contact at 35 A
NC contact at 20 A
Mechanical endurance (without load)
Electrical endurance
(example of resistive load,
further information on request)
Max. switching rate at nominal load
12 V
20/30 A
Stationary and NO movable: AgNi0.15, NC movable: A
See load limit curve
NC/NO
45/120 A
30/45 A
1 A at 5 V
120 A
40 A
200 mV max.
200 mV max.
250 mV max.
Typ. 107 operations
> 1 x 105 operations
30 A, 14 V
> 1 x 105 operations
30 A, 14 V
(NO contact)
6 operations per minute (0.1 Hz)
The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V.
For a load current duration of maximum 3 s for a make/break ratio of 1:10.
3) See chapter Diagnostics in our Application Recommendations on page 18 of this catalog or consult the internet at http://relays.tycoelectronics.com/application.asp
1)
2)
Load limit curve
ECR2115-X
75
Safe breaking, arc extinguished (normally open contact)
for resistive loads with resistor suppression.
60
Switching Voltage (VDC)
50
40
50
0W
30
20
0W
10
0W
20
10
0.5
1
2
3
4
5
7
10
20
30
40
Switching Current (A)
Pin assignment
1 make contact/
1 form A
1 changeover contact/
1 form C
ECR2159-P
ECR2160-S
Resistor if used
Resistor if used
58
Please observe the disclaimer.
Plug-In Relays
Mini 280 Relays
Catalog 1308028
Revision 03-06
VF28
Revision 03-05
Coil data
Available for nominal voltages
Nominal power consumption of the unsuppressed coil at nominal voltage
Nominal power consumption at nominal voltage with suppression resistor
Test voltage winding/contact
Ambient temperature range
Operate time at nominal voltage
Release time at nominal voltage 1)
12, 24 V
1.6 W
1.8 W
500 VACrms
– 40 to + 125 °C
Typ. 7 ms
Typ. 4 ms
For unsuppressed relay coil
N.B.
A low resistive suppression device in parallel to the relay coil increases the release time and reduces
the lifetime caused by increased erosion and/or higher risk of contact tack welding.
1)
Ambient temperature vs. coil voltage for continuous duty
ECR2116-6
140
130
Maximum Allowable Ambient Temperature (°C)
120
110
100
90
80
0 A Contact Load
7 A Contact Load
14 A Contact Load
21 A Contact Load
70
60
Assumptions:
1. Still air
2. Nominal coil resistance
3. Maximum mean coil temperature = 180 °C
4. Coil temperature rise due to load
= 1.3 °C at 7 A
= 3.1 °C at 14 A
= 7.2 °C at 21 A
= 12.1 °C at 28 A
= 19 °C at 35 A
5. Thermal resistance and power dissipation based on coil
resistance at 180 °C
6. Curves are based on 1.6 W at 23 °C
28 A Contact Load
50
35 A Contact Load
40
90
95
100
105
110
115
120
125
130
135
140
145
150
Applied Coil Voltage (% of Nominal Voltage)
ECR2117-E
140
130
Maximum Allowable Ambient Temperature (°C)
120
110
100
90
80
70
0 A Contact Load
6 A Contact Load
12 A Contact Load
18 A Contact Load
24 A Contact Load
30 A Contact Load
60
50
Assumptions:
1. Still air
2. Nominal coil resistance
3. Maximum mean coil temperature = 180 °C
4. Coil temperature rise due to load
= 0.8 °C at 6 A
= 3.6 °C at 12 A
= 6.3 °C at 18 A
= 11 °C at 24 A
= 16.8 °C at 30 A
5. Thermal resistance and power dissipation based on coil
resistance at 180 °C
6. Curves are based on 1.6 W at 23 °C
40
90
95
100
105
110
115
120
125
130
135
140
145
150
Applied Coil Voltage (% of Rated Nominal)
59
Please observe the disclaimer.
Plug-In Relays
Mini 280 Relays
Catalog 1308028
Revision 03-06
VF28
Revision 03-05
Mechanical data
Cover retention
Axial force
Pull force
Push force
Terminals
Pull force
Push force
Resistance to bending, force applied to front
Resistance to bending, force applied to side
Torsion
Enclosures
Dust cover
Shrouded/Weatherproof cover
1)
150 N (33.8 lbs)
200 N (45 lbs)
200 N (45 lbs)
100 N (22.5 lbs)
100 N (22.5 lbs)
10 N (2.25 lbs)1)
10 N (2.25 lbs)1)
0.3 Nm
Protects relay from dust. For use in passenger compartment or enclosures
Mates with VC28-1003 connector for application where weather sealing is not required.
Values apply 2 mm from the end of the terminal. When the force is removed, the terminal must not have moved by more than 0.3 mm.
Operating conditions
Refer to Storage in the “Glossary”
Relevant standard
Testing as per
Dimension
1.27 mm double amplitude
10-40 Hz
5 g constant
40-70 Hz
0.5 mm double amplitude
70-100 Hz
10 g constant
100-500 Hz
Half sine wave pulse
20 g
11 ms
24 VDC for 5 minutes conducting nominal current at 23 °C
Capable of meeting specifications after 1.0 m (3.28 foot) drop onto concrete
UL94-HB or better (meets FMVSS 302)
Temperature range, storage
Test
Vibration resistance
Shock resistance
Jump start
Drop test
Flammability
Overload Current 1)
1)
Comments
Valid for NC contacts.
NO contacts are
significantly higher
No change in the
switching state > 1 ms
Internal
External
40.5 A, 1800 s
60 A, 30 s
105 A, 4 s
180 A, 1 s
Current and time are compatibel with circuit protection by a typical 30 A automotive fuse. Relay will make, carry, and break the specified current.
Ordering information
Part numbers
(see table below for coil data)
Relay part number Tyco order number
VF28-11F14-S01
VF28-11F24-S01
VF28-15F14-S01
VF28-15F24-S01
VF28-61F14-S01
VF28-65F14-S01
0-1393297-1
2-1419084-3
0-1393297-8
1-1393297-3
3-1393297-6
4-1393297-5
Contact
arrangement
1 Form A
1 Form A
1 Form C
1 Form C
1 Form A
1 Form C
Contact
material
AgNi0.15
AgSnO2
AgNi0.15
AgSnO2
AgNi0.15
AgNi0.15
Enclosure
Terminals
Dust Cover
Dust Cover
Dust Cover
Dust Cover
Weatherproof cover with bracket
Weatherproof cover with bracket
680 Ω resistor in parallel
680 Ω resistor in parallel
680 Ω resistor in parallel
680 Ω resistor in parallel
680 Ω resistor in parallel
680 Ω resistor in parallel
Coil versions
Coil
data for
VF28
VF28-**F**-***
VF28-**H**-***
1)
Rated coil
voltage
(V)
Coil
resistance
+/- 10%
(Ω)
Must
operate
voltage
(V)
Must
release
voltage
(V)
12
24
90
360
7.2
14.4
1.2
2.4
Allowable overdrive 1)
voltage (V)
at 23 °C 1)
at 85 °C
20.2
40.5
15.7
31.5
Allowable overdrive is stated with no load applied and minimum coil resistance.
Standard delivery packs (orders in multiples of delivery pack)
Dust cover version:
357 pieces
Weatherproof version with bracket: 110 pieces
60
Please observe the disclaimer.