PF (APF) VDE Compliant with European standards 1a/1c 6A Slim power relays RoHS compliant PF RELAYS (APF) FEATURES TYPICAL APPLICATIONS 1. High density mounting with 5 mm .197 inch width Space saved with 5 mm .197 inch slim type with 28 mm 1.102 inch length. Allows high density mounting and use in compact devices. 2. Satisfies reinforced insulation standard (EN/IEC 61810-1). 3. High switching capacity Supports 6A 250 V AC nominal switching capacity (resistive load) and AC15 and DC13 (inductive load). 4. 1 Form A and 1 Form C contact arrangements with options for a variety of applications. 5. 4,000 V high breakdown voltage and 6,000 V high surge breakdown voltage. Controller protection against surges and noise with a breakdown voltage of 4,000 Vrms for 1 min. between contacts and coil, and 6,000 V surge breakdown voltage between contacts and coil. 6. Resistance to heat and fire; EN60335-1, clause 30 (GWT) approved. 7. Sealed construction allows automatic washing. 8. Complies with all safety standards. UL/C-UL, VDE certified. 1. Interface relays for programmable controllers 2. Output relays for measuring equipment, timers, counters and temperature controllers 3. Industrial equipment, office equipment 4. Household appliances for Europe ORDERING INFORMATION APF 0 Contact arrangement 1: 1 Form A 3: 1 Form C Contact type 0: Single contact Contact material 2: AgNi type 3: AgNi type/Au-plated Nominal coil voltage (DC) 4H: 4.5 V 05: 5 V 06: 6 V 09: 9 V 12: 12 V 18: 18 V 24: 24 V 48: 48 V 60: 60 V Note: Certified by UL/C-UL and VDE ASCTB205E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ PF (APF) TYPES Contact arrangement Nominal coil voltage Part No. 1 Form A (AgNi type) 4.5V DC 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC 60V DC APF1024H APF10205 APF10206 APF10209 APF10212 APF10218 APF10224 APF10248 APF10260 1 Form A (AgNi type/Au-plated) 4.5V DC 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC 60V DC APF1034H APF10305 APF10306 APF10309 APF10312 APF10318 APF10324 APF10348 APF10360 Contact arrangement Nominal coil voltage Part No. 1 Form C (AgNi type) 4.5V DC 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC 60V DC APF3024H APF30205 APF30206 APF30209 APF30212 APF30218 APF30224 APF30248 APF30260 1 Form C (AgNi type/Au-plated) 4.5V DC 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC 60V DC APF3034H APF30305 APF30306 APF30309 APF30312 APF30318 APF30324 APF30348 APF30360 Standard packing: Tube: 20 pcs.; Case: 1,000 pcs. RATING 1. Coil data 4.5V DC Nominal operating current [±10%] (at 20°C 68°F) 37.8mA 5V DC 6V DC 9V DC 12V DC 18V DC 24V DC 48V DC 60V DC 34.0mA 28.3mA 18.9mA 14.2mA 9.4mA 7.1mA 4.5mA 2.9mA Nominal coil voltage Pick-up voltage (at 20°C 68°F) Max. 70%V nominal voltage (Initial) Panasonic Corporation Drop-out voltage (at 20°C 68°F) Min. 5%V nominal voltage (Initial) Automation Controls Business Unit Coil resistance [±10%] (at 20°C 68°F) Nominal operating power Max. applied voltage (at 20°C 68°F) 119Ω 147Ω 212Ω 476Ω 847Ω 1,906Ω 3,388Ω 10,618Ω 20,570Ω 170mW 120%V of nominal voltage 217mW 175mW industrial.panasonic.com/ac/e/ ASCTB205E 201202-T PF (APF) 2. Specifications Characteristic Contact Rating Item Arrangement Contact resistance (Initial) Contact material Nominal switching capacity (resistive load) Max. switching power (resistive load) Max. switching voltage Max. switching current Nominal operating power Min. switching capacity (Reference value)*1 Specifications 1 Form A 1 Form C Max. 100 mΩ (By voltage drop 6 V DC 1A) AgNi type, AgNi type/Au-plated 6 A 250 V AC 1,500 VA 250V AC 6 A (AC) 170 mW (5 to 24 V DC), 217 mW (48 V DC), 175 mW (60 V DC) 100 mA 5 V DC (without Au-plated), 1 mA 1 V DC (with Au-plated) Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section. Insulation resistance (Initial) Between open contacts Between contact and coil Surge breakdown voltage*2 (Between contact and coil) (Initial) Breakdown voltage (Initial) Electrical characteristics Temperature rise (coil) (at 20°C 68°F) Operate time (at 20°C 68°F) Release time (at 20°C 68°F) Shock resistance Mechanical characteristics Expected life Conditions Functional Destructive Functional Vibration resistance Destructive Mechanical Electrical*4 Conditions for operation, transport and storage*3 Unit weight 1,000 Vrms for 1 min. (Detection current: 10 mA) 4,000 Vrms for 1 min. (Detection current: 10 mA) 6,000 V Max. 45°C 113°F (By resistive method, nominal coil voltage applied to the coil; contact carrying current: 6A.) Max. 8 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) Max. 4 ms (Nominal coil voltage applied to the coil, excluding contact bounce time.) (without diode) Min. 49 m/s2 Min. 98 m/s2 (Half-wave pulse of sine wave: 11 ms; (Half-wave pulse of sine wave: 11 ms; detection time: 10µs) detection time: 10µs) Min. 980 m/s2 (Half-wave pulse of sine wave: 11 ms.) 10 to 55 Hz at double amplitude of 1 mm (Detection time: 10µs.) 10 to 55 Hz at double amplitude of 1.5 mm Min. 5×106 (at 180 times/min.) N.O.: Min. 5×104 N.O.: Min. 5×104, N.C.: Min. 3×104 (at resistive load, 6 times/min. and (at resistive load, 6 times/min. and nominal switching capacity) nominal switching capacity) Ambient temperature: –40°C to +85°C –40°F to +185°F; Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Approx. 5 g .18 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *3. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Refer to “Usage, transport and storage conditions” in NOTES. *4. For cycle lifetime, refer to “Cautions for use 4)” in NOTES. ASCTB205E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ PF (APF) REFERENCE DATA 1. Electrical life Tested sample: APF30224 Load type Resistive load AC 15 Inductive load DC 13 Voltage 250V AC 250V AC 24V DC Current 6A 3A 2A Ambient temperature 85°C 185°F 25°C 77°F 25°C 77°F No. of ops. 30,000 20,000 6,000 Notes: 1. Switch contacts are all on N.O. side. 2. AC 15 and DC 13 comply with IEC-60947-5-1 testing conditions. 4. Ambient temperature characteristics Tested sample: APF30224 Measured portion: Inside the coil Ambient temperature: 28°C 82°F Tested sample: APF30224, 6 pcs. 10 90 6 5 4 3 80 2 1 0.5 0.4 0.3 Rate of change, % 3. Coil temperature rise Temperature rise, °C Contact current, A 2. Max. switching capacity (AC) 6A 0A 70 60 50 -40 40 -20 DIMENSIONS (mm inch) Drop-out voltage -5 40 60 85 Ambient temperature, °C -10 -15 10 10 20 30 50 100 250 Contact voltage, V Pick-up voltage 10 0 20 0 30 0 15 5 20 0.2 20 90 100 110 120 130 Coil applied voltage, %V The CAD data of the products with a CAD Data -20 140 mark can be downloaded from: http://industrial.panasonic.com/ac/e/ 1. 1 Form A type External dimensions PC board pattern (Bottom view) 15.0max. .591max. 0.5 .020 0.4 +0.2 −0.1 .016 +.008 −.004 1.2 .047 −0.1 2-0.6 +0.2 2-.024 +.008 −.004 3.78 .149 2-1.0 2-.039 5.04 .198 1.9 .075 21.42 .843 28.0max. 1.102max. 0.48 +0.2 −0.1 .019 +.008 −.004 1.2 .047 3.5±0.5 5.0max. .138±.020 .197max. 3.78 .149 2-1 . 2-. 3 dia 05 . 1d ia. 2-1 . 2-.0 0 dia. 39 dia . CAD Data 21.42 .843 5.04 .198 1.2 .047 1.9 .075 Tolerance: ±0.1 ±.004 Schematic (Bottom view) COIL COM NO General tolerance: ±0.3 ±.012 2. 1 Form C type 2-1 . 2-.0 0 dia. 39 dia . 15.0max. .591max. 0.5 .020 0.4 +0.2 −0.1 .016 +.008 −.004 1.2 .047 +0.2 −0.1 +.008 −.004 2-0.6 2-.024 3.78 .149 +0.2 0.48 +.008 −0.1 .019 −.004 1.2 .047 3-1.0 3-.039 5.04 .198 1.9 .075 3.5±0.5 5.0max. .138±.020 .197max. 5.04 21.42 .198 .843 28.0max. 1.102max. 3-1 . 3-. 3 dia 05 . 1d ia. PC board pattern (Bottom view) External dimensions CAD Data 1.2 .047 5.04 5.04 21.42 .198 .198 .843 3.78 .149 1.9 .075 Tolerance: ±0.1 ±.004 Schematic (Bottom view) COIL NC COM NO General tolerance: ±0.3 ±.012 Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ ASCTB205E 201202-T PF (APF) SAFETY STANDARDS Certification authority File No. UL/C-UL E120782 VDE 40027672 Applicable standard Rating Remarks 277V AC 8A, General use, UL508, CSA C22.2 No.14 24V DC 6A, General use, UL1604 (class I, Division 2, Group A, B, C, D) B300, R300 (Pilot Duty) 250V AC 6A (cosφ = 1.0) 85°C 185°F N.O. side, N.C. side EN/IEC 61810-1 250V AC 8A (cosφ = 1.0) 25°C 77°F N.O. side Insulation: Reinforced insulation between contact and coil. Resistance to heat and fire; EN60335-1, clause 30 (GWT) approved. NOTES Usage, transport and storage conditions 1) Temperature: –40 to +85°C –40 to +185°F 2) Humidity: 5 to 85% RH (Avoid freezing and condensation.) The humidity range varies with the temperature. Use within the range indicated in the graph below. 3) Atmospheric pressure: 86 to 106 kPa Temperature and humidity range for usage, transport, and storage Humidity, %RH 85 Tolerance range (Avoid freezing when used at temperatures lower than 0°C 32°F) 5 –40 –40 (Avoid condensation when used at temperatures higher than 0°C 32°F) 0 +32 Temperature, °C °F 85 +185 4) Condensation Condensation forms when there is a sudden change in temperature under high temperature and high humidity conditions. Condensation will cause deterioration of the relay insulation. 5) Freezing Condensation or other moisture may freeze on the relay when the temperatures is lower than 0°C 32°F. This causes problems such as sticking of movable parts or operational time lags. 6) Low temperature, low humidity environments The plastic becomes brittle if the relay is exposed to a low temperature, low humidity environment for long periods of time. For Cautions for Use. ASCTB205E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/