PA PA-RELAYS THE SLIM POWER RELAY FEATURES • Slim size (width 5 mm .197 inch, height 12.5 mm .492 inch) permits higher density mounting • Wide switching capacity: Control from 100µA 100 mV to 5 A 250 V AC, 30 V DC • High sensitivity: 120 mW (Nominal) (5 to 18 V DC type) • High surge voltage (4000 V) and high breakdown voltage (2000 V) • Shock & vibration resistance (functional): Min. 147m/s2 {15 G} • SIL (single in line) terminal layout • Reinforced according to IEC1131-2 (TÜV) 5 .197 20 .787 12.5 .492 mm inch SPECIFICATIONS (at 20°C 68°F) Contacts Characteristics Arrangement 1a Contact material Gold-clad silver alloy Initial contact resistance, max. 30 mΩ (By voltage drop 6 V DC 1 A) Nominal switching capacity 5 A 250 V AC, 5 A 30 V DC Maximum switching power 750 VA, 90 W Rating Maximum switching voltage 250 V AC, 110 V DC (resistive) Max. switching current 5A Min. switching capacity 100µA, 100 mV DC 2×107 Expected life Mechanical (min. 3 A 250 V AC, 3 A 30 V DC, 105 operations) Electrical (at 20 cpm) 5 A 250 V AC, 5 A 30 V DC, 5×104 Max. operating speed Initial insulation resistance*1 Initial break- Between open contacts down Between contacts and coil voltage*2 Surge voltage between contacts and coil*3 Operate time*4 (at nominal voltage) Release time (without diode)*4 (at nominal voltage) Coil (at 25°C 77°F, 50% R.H.) Shock resistance Nominal operating power 5 to 18 V DC 24 V DC 120 mW 180 mW Temperature rise Functional*5 Destructive*6 Functional*7 Vibration resistance Remarks Destructive * Specifications will vary with foreign standards certification ratings. *1 Measurement at same location as "Intial breakdown voltage" section *2 Detection current: 10mA *3 Wave is standard shock voltage of ±1.2×50µs according to JEC-212-1981 *4 Excluding contact bounce time *5 Half-wave pulse of sine wave: 11ms; detection time: 10µs *6 Half-wave pulse of sine wave: 6ms *7 Detection time: 10µs *8 Refer to 5. Conditions for operation, transport and storage mentioned in AMBIENT ENVIRONMENT (Page 61). TYPICAL APPLICATIONS Conditions for operation, Ambient temp. transport and storage*8 (Not freezing and condensHumidity ing at low temperature) Unit weight 20 cpm at rated load Min. 1,000 MΩ at 500 V DC 1,000 Vrms 2,000 Vrms 4,000 V Approx. 6 ms Approx. 3 ms Max. 45°C with nominal coil voltage across coil and at nominal switching capacity Min. 147 m/s2 {15 G} Min. 980 m/s2 {100 G} Min. 147 m/s2 {15 G}, 10 to 55 Hz at double amplitude of 2.5 mm Min. 205.8 m/s2 {21 G}, 10 to 55 Hz at double amplitude of 3.5 mm –40°C to +70°C –40°F to +158°F 5 to 85%R.H. Approx. 3 g .15 oz ORDERING INFORMATION • Interface relays for programmable controllers • Output relays for measuring equipment, timers, counters and temperature controllers • Industrial equipment, office equipment Ex. PA 1a 12V Contact arrangement Coil voltage (DC) 1a: 1 Form A 5, 6, 9, 12, 18, 24V Note: Standard packing: Tube: 25 pcs.; Case: 1,000 pcs. UL/CSA, TÜV approved type is standard. TYPES AND COIL DATA Part No. PA1a-5VV PA1a-6VV PA1a-9VV PA1a-12V PA1a-18V PA1a-24V *1 Pulse driving 214 Nominal voltage, V DC 5 6 9 12 18 24 (at 20°C 68°F) Pick-up voltage,* V DC (max.) 3.5 4.2 6.3 8.4 12.6 16.8 Drop-out voltage,* V DC (min.) 0.25 0.3 0.45 0.6 0.9 1.2 Nominal operating current, mA (±10%) 24 20 13.3 10 6.7 7.5 Nominal operating power, mW 120 120 120 120 120 180 Coil resistance, Ω (±10%) 208 300 675 1,200 2,700 3,200 Max. allowable voltage, V DC 6 7.2 10.8 14.4 21.6 28.8 PA DIMENSIONS mm inch 1. PA relay 8.8 .346 PC board pattern (Copper-side view) 0.5 .020 1.3 .051 6 4.8 .237 .189 3.5 .138 5 .197 0.5 .020 10.16 .400 20 .787 2.54 .100 2.54 .100 5.08 .200 0.8 .031 1.11 .044 0.25 .010 1.18 .046 Standard type 1 2 3 Self clinching type 4 5 6 5+0.2 –0.6 .197±.008 –.024 1 2 3 4 5 PC board pattern (Copper-side view) 6 5+0.2 –0.6 .197±.008 –.024 Standard type 22.6±0.6 .890±.024 2.54 .100 9±0.6 .354±.024 5.3±0.6 .209±.024 0.5 .020 0.8 .031 2.54 .100 6.35 .250 3.81 .150 0.25 .010 1.23 .048 1±0.25 .039±.010 1.23 .048 3.9 .154 0.5 .020 2.54 .100 6.35 .250 0.8 .031 3.81 .150 (0.3) (.012) 5.08 .200 5.08 .200 2-1.2 dia. 2-.047 dia. Self clinching type 2.54 .100 1.3±0.15 .051±.006 10.16 .400 5.08 .200 2-0.8±0.25 dia. 2-.031±002 dia. PA1a-PS-H PA1a-PS 10.16 .400 2-1 dia. 2-.039 dia. 5.3±0.6 .209±.024 (0.3) (.012) 5.08 .200 Tolerance: ±0.1 ±.004 N.O. COM 9±0.6 .354±.024 4 .157 5.08 .200 Coil 22.6±0.6 .890±.024 PA1a-PS 10.16 .400 Schematic (Bottom view) General tolerance: ±0.3 ±.012 2. Socket 1.2 dia. .047 dia. 1.2 dia. .047 dia. 1.0 dia. .039 dia. 1.0 dia. .039dia. 1.2 .047 12.5 2.9 (12.8 max.) .114 .492 (.504 max.) 2-1.2±0.05 dia. 2-.047±002 dia. Tolerance: ±0.1 ±.004 REFERENCE DATA 1. Max. switching capacity 2. Life curve 3.-(1) Coil temperature rise (120 mW) Sample: PA1a-12V Ambient temperature: 20°C 68°F Measured portion: Inside the coil AC resistive load 5 4 3 2 1 DC resistive load 90 Temperature rise, °C No. of operations, ×104 Contact current, A 100 100 50 30 20 10 70 60 50 5A 3A 2A 0A 40 30 AC 125 V resistive load DC 30 V resistive load AC 250 V resistive load 0.5 0.4 0.3 0.2 80 20 10 20 30 50 100 200 300 Contact voltage, V 0.5 1 2 3 5 10 Swiching capacity, A 0 100 100 110 120 130 140 150 Coil applied voltage, %V 3.-(2) Coil temperature rise (180 mW) 4.-(1) Operate & release time (120 mW) 4.-(2) Operate & release time (180 mW) Sample: PA1a-24V Ambient temperature: 20°C 68°F Measured portion: Inside the coil Sample: PA1a-12V No. of samples: n = 20 Sample: PA1a-24V No. of samples: n = 20 9 80 70 60 50 40 5A 3A 2A 0A 30 20 8 7 6 4 3 1 0 0 110 120 130 140 150 Coil applied voltage, %V Release time Max. x Min. Max. x Min. 2 10 100 Operate time 5 80 90 100 110 120 Coil applied voltage, %V Operate & release time, ms 10 9 Operate & release time, ms 10 90 Temperature rise, °C 100 8 7 6 Operate time 5 4 3 Release time 2 1 0 80 Max. x Min. Max. x Min. 90 100 110 120 Coil applied voltage, %V 215 PA 5. Ambient temperature characteristics 6. Malfunctional shock Sample: PA1a-12V No. of samples: n = 6 Sample: PA1a-12V No. of samples: n = 6 Rate of change, % 40 30 20 X Pick-up voltage Z Z’Y’ Y 80 X’ 60 40 20 X 980m/s2 10 Drop-out voltage –40 –20 20 0 –10 –20 50 75 Z 980m/s2 20 40 60 80 980m/s2 Z’ Ambient temperature, °C Deenergized condition Energized condition Y 980m/s2 –30 980m/s2 X’ 100 Y’ –40 NOTES 1. Specification values for pick-up and drop-out voltages are for the relay mounting with its terminals below. 100 2. When mounting the relays within 1 mm. .039 inch , please notice the condition below. 1) Mount the relays in the same direction. 3.0 Within 1 mm .039 inch 90 2.0 Voltage, %V Pick-up voltage 60 Contact current, A 80 70 3) Allowable contact current is 2 A. 4) About the electrical life for close mounting, please refer to data below. Max. – x Min. 50 40 DC resistive load 1.0 0.5 0.4 0.3 30 20 AC resistive load Drop-out voltage 10 0 Max. – x Min. 0.2 2) Coil terminals (Terminal No. 1 & 2) polarity should be arranged in the same direction. 20 30 50 100 Contact voltage, V 200 300 –. +. –. +. –. +. –. +. –. +. +. –. +. –. +. –. +. –. +. –. No. of operations, ×104 Mounting direction 100 50 40 30 20 AC 125V resistive load DC 30 V resistive load AC 250 V resistive load 10 0.5 1.0 2.0 3.0 Switching capacity, A For Cautions for Use, see Relay Technical Information (Page 48 to 76). 216 9/1/2000 All Rights Reserved, © Copyright Matsushita Electric Works, Ltd. Go To Online Catalog