MA-COM MASYVS0061

Synthesizer , SMT
1046 — 1085 MHz, 200 kHz
MASYVS0061-1066
Rev: E
Features
♦ Fully Integrated VCO, PLL, Loop Filter
♦ High Performance, Low Cost
♦ Miniature SMT Package (LSM6)
Description
This synthesizer design integrates a high performance VCO, PLL,
IC and discrete loop filter in a surface mount package. This SMT
package provides electrical shielding, easy PCB assembly and repeatable performance. The synthesizer is designed for use in wireless base stations.
M/A-COM synthesizers are manufactured in an ISO9001 certified
facility, incorporating surface mount assembly and automated electrical testing. This ensures consistent electrical performance and
quality over volume production quantities.
Electrical Specifications1:
TA = +25°C, Z0 = 50 Ohms, Fref = 10MHz, Vcc1 = 5V, Vcc2 = 3.3V.
Parameter
Test Conditions
Units
Min
Frequency Range
Over Top
2
MHz
1046
1085
RF Output Power
Over Top 2
dBm
+2.5
+7.5
Phase Noise
SSB at 600 kHz offset from carrier
SSB at 800 kHz offset from carrier
SSB at 1800 kHz offset from carrier
SSB at 6000 kHz offset from carrier
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
-145
-151
-153
-160
-144
-148
-151
-157
dBc
-33
-20
-85
-87
-93
-97
-100
-79
-84
-90
-95
-97
Harmonic Suppression
Spurious Suppression
(Non-Harmonic)
Phase comparison frequency ( ± 200 kHz)
± 400 kHz
± 600 kHz
± 800 kHz
Reference breakthrough ( ± 10 MHz)
dBc
dBc
dBc
dBc
dBc
Frequency Lock Time
Over Fout , Measured to within ± 4 degrees
υs
Phase Error (rms)
Typ
Max
450
Measured over 577υs time slot
Degree
0.6
1.0
Phase Error (peak)
Measured over 577υs time slot
Degree
1.7
4
VCO Supply Current (ICC1)
Recommended operating condition
mA
47
55
PLL Supply Current (ICC2)
Recommended operating condition
mA
13
15
VCO Power Supply (VCC1)
Recommended operating condition
V
+4.75
+5.00
+5.25
PLL Power Supply (VCC2)
Recommended operating condition
V
+3.1
+3.3
+3.5
1. All specification limits are indicated values @ +25 ºC and apply over Fout unless otherwise stated.
2. Top = -40ºC to +85ºC operating temperature.
1
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/ACOM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/ACOM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Synthesizer , SMT
1046 — 1085 MHz, 200 kHz
MASYVS0061-1066
Electrical Specifications1: (cont’d)
Parameter
Test Conditions
Units
Step Size (∆F)
Recommended operating limit
kHz
Reference Frequency (FR)
1.0 V pp ± 0.2V square wave with input filter
MHz
Min
Typ
Max
200
10
100
PLL Programming
3-wire serial CMOS IAW ADF4113, Charge Pump 5 mA
Logic high = VCC2 x 0.8 Min and Logic low = VCC2 x 0.2 Max
PLL Lock Monitor Output
Locked = VCC2 - 0.4 Min , Unlocked = 0.4V Max
Absolute Maximum Ratings
TA = +25°C
Pin Configuration
Pin No.
Function
Pin No.
Function
Parameter
Absolute Maximum
1
VCC1
8
GND
VCO Supply Voltage (VCC1)
-0.3V to 6.5 V
2
GND
9
Lock Detect
PLL Supply Voltage (VCC1)
-0.3V to 6.5 V
3
REF I/P
10
Clock
Reference Frequency Level
-0.3V to 6.5 V
4
GND
11
Data
-0.3V to Vcc + 0.3 V
5
VCC2
12
Load Enable
Data, Clock, Strobe
Voltages
Operating Temperature
-40°C to +85°C
6
GND
13
GND
Storage Temperature
-45°C to +120°C
7
RF O/P
14
GND
Solder Assembly
Temperature
See App Note M2032
Functional Block Diagram
1. Operation of this device above any one of these parameters
may cause permanent damage.
2. Static sensitive, observe appropriate handling precautions.
Environmental Specifications
Devices are designed to function after exposure to the
shock, vibration, thermal shock and moisture conditions
typically encountered in base station and other infrastructure environments.
Ordering Information
1. The diagram above shows a typical application.
2. The Reference input and RF output are internally AC coupled.
3. The diagram applies when digital lock detect is selected. For
analog open-drain mode, a filter is required. See AN3003 for
design information.
Part Number
Package
MASYVS0061-1066 B
Bulk Packaging
MASYVS0061-1066 T
Tape and Reel (300/Reel) 1
MASYVS0061-1066 R
Reverse Tape and Reel
(300/Reel) 1
1. See application note M513.
2
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/ACOM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/ACOM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.
Synthesizer , SMT
1046 — 1085 MHz, 200 kHz
MASYVS0061-1066
Recommended PCB Layout
Outline Drawing
3
M/A-COM Inc. and its affiliates reserve the right to make changes to
the product(s) or information contained herein without notice. M/ACOM makes no warranty, representation or guarantee regarding the
suitability of its products for any particular purpose, nor does M/ACOM assume any liability whatsoever arising out of the use.
or application of any product(s) or information.
• North America Tel: 800.366.2266 / Fax: 978.366.2266
• Europe Tel: 44.1908.574.200 / Fax: 44.1908.574.300
• Asia/Pacific Tel: 81.44.844.8296 / Fax: 81.44.844.8298
Visit www.macom.com for additional data sheets and product information.