RHOMBUS-IND T

T1/CEPT/ISDN PRI Interface Transformer
Electrical Specifications @ 250C
Turns Ratio ( + 3% )
1CT : 2CT (T1) & 1 : 1 (T2)
PARAMETER
MIN.
OCL (Primary)
1.2
MAX.
UNITS
mH
Leakage Inductance
0.8 / 0.5
µH
Capacitance (CW/W)
50
pF
Primary DC Resistance
0.8
Ohms
Secondary DC Resistance
1.8 & 0.8
Ohms
Operating Temp Range
Flammability: Materials used in
the production of these units
meet requirements of UL94-VO
and IEC 695-2-2 needle flame
test.
-40
+85
0
Parts shipped in anti-static
tubes. 33 pieces per tube
Tape & Reel
Available
C
Isolation 2000 VRMS Min.
Primary Pins 1-3 & 11-9
PHYSICAL DIMENSIONS
inches (mm)
Schematic Diagram
Secondary
Primary
T1
Primary
Rhombus
Industries Inc.
T2
Rhombus P/N:
Secondary
Transformers & Magnetic Products
Cust. P/N:
12/22/98
Date:
www.rhombus-ind.com
T-14107
Name:
Sheet:
1 of 1
15801 Chemical Lane,
Huntington Beach, CA 92649
Phone: (714) 898-0960
FAX: (714) 896-0971