FM-104 Broadband Frequency Doubler, 150 - 3000 MHz Output Rev. V3 Features n n n n n n FP-3 Hermetic Flatpack Multioctave Frequency Coverage Conversion Loss: 10 dB Midband Impedance: 50 Ohms Nominal Maximum Input Power: 300 mW Max. MIL-STD-202 Screening Available Description A transmission line balun transformer connects to Schottky diodes arranged in a bridge configuration. This design allows balanced activation of all diodes, and yields excellent conversion loss, and odd-order term suppression. Pin Configuration Pin No. Function Pin No. Function 1 GND 6 GND 2 GND 7 GND 3 Input 8 Output 4 GND 9 GND 5 GND 10 GND Electrical Specifications1: TA = -55°C to +85°C Parameter Test Conditions Frequency Units Min Typ Max Frequency Range Input Output 75 - 1500 150 - 3000 MHz MHz — — — — — — 75 - 1000 MHz 1000 - 1500 MHz dB dB — — — — 12 14 75 - 1000 MHz 1000 - 1500 MHz 225 - 3000 MHz 3000 - 4500 MHz dB dB dB dB 20 17 20 17 — — — — — — — — Conversion Loss Spurious (Referred to Output F2 Level) F1 F3 VSWR Input — Ratio — <2.5:1 — Conversion Loss as Quadrupler — — dB — 26 — 1. All specifications apply when operated at +13 dBm input power with 50 ohm source and load impedance. 1 ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400 considering for development. Performance is based on target specifications, simulated results, and/or prototype • India Tel: +91.80.43537383 • China Tel: +86.21.2407.1588 measurements. Commitment to develop is not guaranteed. Visit www.macomtech.com for additional data sheets and product information. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make not guaranteed. changes to the product(s) or information contained herein without notice. FM-104 Broadband Frequency Doubler, 150 - 3000 MHz Output Rev. V3 Typical Performance Curves Conversion Loss vs. Input Power Conversion Loss 20 Conversion Loss (dB) Conversion Loss (dB) 13 18 12 16 14 11 12 10 10 9 75 100 200 300 500 750 1000 1500 8 0 2000 4 8 Input F re que nc y ( M H z) 16 20 Spurious Response F3 Spurious Referenced to F2 Output (dB) Spurious Response 40 F1 Spurious Referenced to F2 Output (dB) 40 35 35 30 30 25 75 100 150 200 300 500 1000 2000 25 225 300 450 600 900 1500 2000 6000 O ut put F re que nc y ( M H z) O ut put F re que nc y ( M H z) Spurious Response F4 Spurious Referenced to F2 Output (dB) 12 Input P o wer (dB m ) Ordering Information 28 24 Part Number Package FM-104 PIN FP-3 20 16 12 300 400 600 800 1200 2000 4000 8000 O ut put F re que nc y ( M H z) 2 ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions is • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400 considering for development. Performance is based on target specifications, simulated results, and/or prototype • India Tel: +91.80.43537383 • China Tel: +86.21.2407.1588 measurements. Commitment to develop is not guaranteed. Visit www.macomtech.com for additional data sheets and product information. PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology Solutions has under development. Performance is based on engineering tests. Specifications are typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available. Commitment to produce in volume is M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make not guaranteed. changes to the product(s) or information contained herein without notice.