POWER-SYSTEMS CXA-P1012-NJL

DC-AC INVERTER UNIT
CXA-P1012-NJL (9.0W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
DESCRIPTION:
This DC to AC Inverter was developed for large size LCD panel
as Multiple Media, Replacement of CRT Monitor and other
general Purpose.
APPLICABLE LCD:
9 to 15 inches Double lamp type
Lamp Voltage 600V
Lamp Current 5mA
CXA-P1012-NJL
LOT. 7X
FEATURES :
High Efficiency (85%)
Fuse protection
Low noise with voltage resonant circuit
8mm Low Profile
TEMPERATURE & HUMDITY :
Operating Temperature Range
Storage Temperature Range
Humidity
MADE IN JAPAN
-10 °C ~ +60°C
-30 °C ~ +85°C
95 %RH max
DIMENSIONS :
130.5 max
124±0.2
48±0.2
3±0.3
Unit:
mm
Weight: 21.0g typ.
CN2
CN3
1
1
1
CN1
4
2
1
b
3
b
8 max
14±0.2 (3)
3±0.3
20.5 max
3-φ2.2±0.1
No.
P art Dis c ription
Qty .
M aterial
Note
1
P CB
1
UL94V -0 (FR-4 or CE M -3)
t= 1.0m m
2
Connec tor CN1
1
S 5B -P H-S M 3
JS T
3
Connec tor CN2
1
S M 02(8.0)B -B HS -1
JS T
4
Connec tor CN3
1
S M 02(8.0)B -B HS -1
JS T
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 1 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-P1012-NJL (9.0W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
Input Side CN1:
P in
CN
CN
CN
CN
CN
No. S ym bols
1-1
V in
1-2
GND
1-3
N.C.
1-4
1-5
Output Side CN2, CN3:
P in No.
Ra tings
12V
0V
CN 2-1
CN 2-2
CN 2-3
S ym bols
V HIGH 1, 2
N.C.
V LOW 1, 2
CN 3-1
CN 3-2
CN 3-3
Ra tings
600 V rm s
(2V )
-
ELECTRICAL CHARACTERISTICS:
Ite m s
S ym bols
Iout1
Output Curre nt
Iout2
Conditions
S pe cifica tion
V in (V ) Ta (°C) RL 1, 2 (K Ω ) M in.
12±0.12 18~ 28
120
Iout2
Iin
Fre que ncy
F
Ope n Circuit V olta ge
V ope n 1, 2
Unit
4.5
5.0
5.5
4.0
5.0
6.0
-
620
900
30
37
44
kHz
-
V rm s
m Arm s
Iout1
Input Curre nt
Typ. M a x .
12±0.6
110~ 130
-10~ 60
∞
1400 1500
m A DC
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 2 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-P1012-NJL (9.0W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
APPLICATION (For Example):
Non Dimming Type
CN1-1(Vin)
Vin
12V
CN2-1(Vhigh1)
Iout1
CCFL1
RL1
CN1-2(GND)
CN2-3(Vlow1)
CN1-5(NC)
CN3-1(Vhigh2)
Iout2
CCFL2
RL2
CN1-3(NC)
CN3-3(Vlow2)
CN1-4(NC)
Dimming by DC/DC
Converter
CN1-1(Vin)
CN2-1(Vhigh1)
Iout1
CCFL1
RL1
CN1-2(GND)
DC/DC Converter
(Mother Board)
CN2-3(Vlow1)
CN1-5(NC)
CN3-1(Vhigh2)
Iout2
CN1-3(NC)
CCFL2
RL2
CN1-4(NC)
CN3-3(Vlow2)
CN1-1(Vin)
CN2-1(Vhigh1)
Dimming by PWM
Iout1
CCFL1
RL1
CN1-2(GND)
Duty Dimmig
(Mother Board)
CN2-3(Vlow1)
CN1-5(NC)
CN3-1(Vhigh2)
Iout2
CN1-3(NC)
CCFL2
RL2
CN3-3(Vlow2)
CN1-4(NC)
TEST CIRCUIT:
O s c illo s c o p e
F
V in
12V
A
-
V
~
Ii n
V
-
C N 1-1
C N 2-1
C N 1-2
C N 2-3
NC
C N 1-3
NC
C N 1-4
NC
C N 1-5
R L1
1 0 0 0 :1
V open1
A
~
Io u t1
V
~
C N 3-1
C N 3-3
R L2
A
~
1 0 0 0 :1
V open2
Io u t2
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 3 / 4 )
VER, 04 October 2002
DC-AC INVERTER UNIT
CXA-P1012-NJL (9.0W DUAL OUTPUTS)
(PRELIMINARY INFORMATION)
Note 1.
For circuit connection, please prefer to test circuit diagram.
Note 2.
Please use minimum of 2mm clearance (all directions) between inverter high voltage area and any
conductors. Please refer to mechanical drawing for marking of high voltage area.
Note 3.
Open voltage (strike voltage) is measured across the transformer secondary winding at no load as the
reading at the output connector would be less than the actual value.
Note 4.
The output of this dc-ac inverter is insulated in electricity with the input part.
Please use CN2-3 and CN3-3 side when you connect the Vlow side of the output with the ground.
Note 5.
Please use the screw of the insulator to prevent the electrical discharge or make the installation. Screw the
first side and an insulated structure in electricity because the output pattern of a high voltage is laid out to
be near when you use the installation hold of part b in the externals dimensional drawing.
Note 6.
If the start up voltage falls below Cold Cathode Tube strike voltage, the CCFL will not light up easily
specially at lower ambient temperature. Please review mounting instruction to avoid any abnormal
operation due to coupling/leakage capacitance of inverter high voltage area to any surrounding conductor.
Power Systems – The Power Solution
Web:
Email:
www.Power-Systems.de
[email protected]
All specification are subject to change without notice.
Address: Dörnet 8 ; 74360 Ilsfeld-Auenstein / Germany
Tel. :
+ 49 / 70 62 / 67 59 - 6
Fax:
+ 49 / 70 62 / 67 59 - 80
Page ( 4 / 4 )
VER, 04 October 2002