MEANWELL PLC

PLC-30
30W Single Output LED Power Supply
series
Features :
Universal AC input / Full range
Adjustable output voltage and current level
Protections: Short circuit / Over current / Over voltage / Over temperature
Cooling by free air convection
Built-in constant current limiting circuit
Fully isolated plastic case with terminal block style of I/O
Built-in active PFC function, comply with EN61000-3-2 class C
(Pin 25W)
Class
power unit, no FG
Class 2 power unit
100% full load burn-in test
High reliability
Suitable for LED lighting and moving sign applications (Note.2)
Compliance to worldwide safety regulations for lighting
2 years warranty
110
F
M
M
SELV
( for 48V only)
SPECIFICATION
MODEL
DC VOLTAGE
PLC-30-9
PLC-30-12
PLC-30-15
PLC-30-20
PLC-30-24
PLC-30-27
PLC-30-36
PLC-30-48
9V
12V
15V
20V
24V
27V
36V
48V
8.4 ~ 12V
10.5 ~ 15V
14 ~ 20V
16.8 ~ 24V
18.9 ~ 27V
25.2 ~ 36V
33.6 ~ 48V
1.5A
1.25A
1.12A
0.84A
0.63A
CONSTANT CURRENT REGION Note.6 6.3 ~ 9V
OUTPUT
RATED CURRENT
3.3A
2.5A
2A
CURRENT RANGE
0 ~ 3.3A
0 ~ 2.5A
0 ~ 2A
0 ~ 1.5A
0 ~ 1.25A
0 ~ 1.12A
0 ~ 0.84A
0 ~ 0.63A
RATED POWER
29.7W
30W
30W
30W
30W
30.24W
30.24W
30.24W
RIPPLE & NOISE (max.) Note.2 2.6Vp-p
2Vp-p
2.6Vp-p
2.6Vp-p
2.4Vp-p
2.3Vp-p
3.6Vp-p
3.7Vp-p
VOLTAGE ADJ. RANGE Note.5 8.55 ~ 9.9V
11.4 ~ 13.2V
14.5 ~ 16.5V
19 ~ 22V
22.8 ~ 26.4V
25.65 ~ 29.7V
34.2 ~ 39.6V
45.6 ~ 52.8V
CURRENT ADJ. RANGE Note.5 2.475 ~ 3.399A 1.875 ~ 2.575A 1.5 ~ 2.06A
VOLTAGE TOLERANCE Note.3
10%
LINE REGULATION
3.0%
Note.4 90 ~ 264VAC
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
EFFICIENCY (Typ.)
80%
82.5%
AC CURRENT (Typ.)
INRUSH CURRENT (max.)
0.4A/115VAC
40A/230VAC
0.2A/230VAC
LEAKAGE CURRENT
<0.5mA / 240VAC
OVER CURRENT
100 ~ 110%
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
OVER TEMPERATURE
WORKING TEMP.
WORKING HUMIDITY
ENVIRONMENT STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
SAFETY &
EMC
84%
84%
Hiccup mode, recovers automatically after fault condition is removed.
10 ~ 14V
14 ~ 16V
17 ~ 22V
23 ~ 26V
27 ~ 34V
84.5%
31 ~ 35V
85%
85.5%
40 ~ 50V
53 ~ 63V
Protection type : Shut down o/p voltage, re-power on to recover
95
10
(TSW1)
Protection type : Shut down o/p voltage, re-power on to recover
-30 ~ +50
(Refer to "Derating Curve")
20 ~ 95% RH non-condensing
-40 ~ +80
0.06%/
, 10 ~ 95% RH
(0 ~ 50
)
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY STANDARDS
UL1310, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), J61347-1, J61347-2-13 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH
Compliance to EN55015, EN61000-3-2 Class C (Pin
EMC EMISSION
DIMENSION
PACKING
NOTE
83.5%
VIBRATION
EMC IMMUNITY
MTBF
OTHERS
127 ~ 370VDC
FREQUENCY RANGE
SHORT CIRCUIT
PROTECTION
0.473 ~ 0.649A
2000ms / 230VAC 3000ms / 115VAC at full load
SETUP TIME
VOLTAGE RANGE
1.125 ~ 1.545A 0.938 ~ 1.288A 0.84 ~ 1.1536A 0.63 ~ 0.865A
5.0%
LOAD REGULATION
INPUT
( except for 48V )
25W), Class D (>70% load) ; EN61000-3-3
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level, criteria B
625.5Khrs min. MIL-HDBK-217F (25
160*46*30mm (L*W*H)
0.2Kg; 70pcs/15Kg/0.96CUFT
)
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please
reconfirm special electrical requirements for some specific system design.
7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the
complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again.
8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
File Name:PLC-30-SPEC 2012-03-12
PLC-30
30W Single Output LED Power Supply
Mechanical Specification
Case No. 990A
series
Unit:mm
160
3.2
23
9
2-R2
2-R6.5
46
T case
80
1
Vo
ADJ
Io
ADJ
9
2
3.2
1
30
2
2.3
T case: Max. Case Temperature.
Terminal Pin No. Assignment (TB1) :
SWITCHLAB MB310-75002
Pin No.
1
2
Terminal Pin No. Assignment (TB2) :
SWITCHLAB MB310-75002
Assignment
AC/N
AC/L
Pin No.
1
2
Assignment
+V
-V
Block Diagram
fosc : 39KHz(115VAC)
53KHz(230VAC)
EMI FILTER
&
RECTIFIERS
I/P
RECTIFIERS
&
FILTER
POWER
SWITCHING
+V
-V
DETECTION
CIRCUIT
O.L.P.
PWM & PFC
CONTROL
O.C.P.
O.V.P.
Derating Curve
Static Characteristics
100
100
90
80
80
70
LOAD (%)
LOAD (%)
60
40
20
-30
-25
-5
0
15
30
40
AMBIENT TEMPERATURE ( )
50
60
60
50
40
90
100
125
135
145
155 165
175
180
200
230
264
INPUT VOLTAGE (V) 60Hz
File Name:PLC-30-SPEC 2012-03-12
PLC-30
30W Single Output LED Power Supply
series
Power Factor Characteristic
Constant Current Mode
PF
1 .0 0
0 .9 8
0 .9 6
0 .9 4
0 .9 2
0 .9 0
0 .8 8
0 .8 6
0 .8 4
0 .8 2
0 .8 0
0 .7 8
230V
115V
50%
60%
70%
80%
90%
100%
(30W)
LOAD
EFFICIENCY vs LOAD (48V Model)
PLC-30 series possess superior working efficiency that up to 85.5% can be reached in field applications.
EFFICIENCY (%)
90
88
86
84
82
80
78
76
74
72
70
68
66
64
62
60
58
56
54
230V
115V
10%
20%
30%
40%
50%
60%
70%
80%
90% 100%
LOAD
DRIVING METHODS OF LED MODULE
This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs.
100
Vo(%)
Constant
Current area
70
(max.)
Hiccup
Protection
50
100
Io (%)
Typical LED power supply I-V curve
File Name:PLC-30-SPEC 2012-03-12