PLC-30 30W Single Output LED Power Supply series Features : Universal AC input / Full range Adjustable output voltage and current level Protections: Short circuit / Over current / Over voltage / Over temperature Cooling by free air convection Built-in constant current limiting circuit Fully isolated plastic case with terminal block style of I/O Built-in active PFC function, comply with EN61000-3-2 class C (Pin 25W) Class power unit, no FG Class 2 power unit 100% full load burn-in test High reliability Suitable for LED lighting and moving sign applications (Note.2) Compliance to worldwide safety regulations for lighting 2 years warranty 110 F M M SELV ( for 48V only) SPECIFICATION MODEL DC VOLTAGE PLC-30-9 PLC-30-12 PLC-30-15 PLC-30-20 PLC-30-24 PLC-30-27 PLC-30-36 PLC-30-48 9V 12V 15V 20V 24V 27V 36V 48V 8.4 ~ 12V 10.5 ~ 15V 14 ~ 20V 16.8 ~ 24V 18.9 ~ 27V 25.2 ~ 36V 33.6 ~ 48V 1.5A 1.25A 1.12A 0.84A 0.63A CONSTANT CURRENT REGION Note.6 6.3 ~ 9V OUTPUT RATED CURRENT 3.3A 2.5A 2A CURRENT RANGE 0 ~ 3.3A 0 ~ 2.5A 0 ~ 2A 0 ~ 1.5A 0 ~ 1.25A 0 ~ 1.12A 0 ~ 0.84A 0 ~ 0.63A RATED POWER 29.7W 30W 30W 30W 30W 30.24W 30.24W 30.24W RIPPLE & NOISE (max.) Note.2 2.6Vp-p 2Vp-p 2.6Vp-p 2.6Vp-p 2.4Vp-p 2.3Vp-p 3.6Vp-p 3.7Vp-p VOLTAGE ADJ. RANGE Note.5 8.55 ~ 9.9V 11.4 ~ 13.2V 14.5 ~ 16.5V 19 ~ 22V 22.8 ~ 26.4V 25.65 ~ 29.7V 34.2 ~ 39.6V 45.6 ~ 52.8V CURRENT ADJ. RANGE Note.5 2.475 ~ 3.399A 1.875 ~ 2.575A 1.5 ~ 2.06A VOLTAGE TOLERANCE Note.3 10% LINE REGULATION 3.0% Note.4 90 ~ 264VAC 47 ~ 63Hz POWER FACTOR (Typ.) PF>0.95/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve) EFFICIENCY (Typ.) 80% 82.5% AC CURRENT (Typ.) INRUSH CURRENT (max.) 0.4A/115VAC 40A/230VAC 0.2A/230VAC LEAKAGE CURRENT <0.5mA / 240VAC OVER CURRENT 100 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed OVER VOLTAGE OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT SAFETY & EMC 84% 84% Hiccup mode, recovers automatically after fault condition is removed. 10 ~ 14V 14 ~ 16V 17 ~ 22V 23 ~ 26V 27 ~ 34V 84.5% 31 ~ 35V 85% 85.5% 40 ~ 50V 53 ~ 63V Protection type : Shut down o/p voltage, re-power on to recover 95 10 (TSW1) Protection type : Shut down o/p voltage, re-power on to recover -30 ~ +50 (Refer to "Derating Curve") 20 ~ 95% RH non-condensing -40 ~ +80 0.06%/ , 10 ~ 95% RH (0 ~ 50 ) 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes SAFETY STANDARDS UL1310, TUV EN61347-1, EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), J61347-1, J61347-2-13 approved WITHSTAND VOLTAGE I/P-O/P:3.75KVAC ISOLATION RESISTANCE I/P-O/P:100M Ohms / 500VDC / 25 / 70% RH Compliance to EN55015, EN61000-3-2 Class C (Pin EMC EMISSION DIMENSION PACKING NOTE 83.5% VIBRATION EMC IMMUNITY MTBF OTHERS 127 ~ 370VDC FREQUENCY RANGE SHORT CIRCUIT PROTECTION 0.473 ~ 0.649A 2000ms / 230VAC 3000ms / 115VAC at full load SETUP TIME VOLTAGE RANGE 1.125 ~ 1.545A 0.938 ~ 1.288A 0.84 ~ 1.1536A 0.63 ~ 0.865A 5.0% LOAD REGULATION INPUT ( except for 48V ) 25W), Class D (>70% load) ; EN61000-3-3 Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61547, light industry level, criteria B 625.5Khrs min. MIL-HDBK-217F (25 160*46*30mm (L*W*H) 0.2Kg; 70pcs/15Kg/0.96CUFT ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details. 5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB. 6. Constant current operation region is within 70% ~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers. File Name:PLC-30-SPEC 2012-03-12 PLC-30 30W Single Output LED Power Supply Mechanical Specification Case No. 990A series Unit:mm 160 3.2 23 9 2-R2 2-R6.5 46 T case 80 1 Vo ADJ Io ADJ 9 2 3.2 1 30 2 2.3 T case: Max. Case Temperature. Terminal Pin No. Assignment (TB1) : SWITCHLAB MB310-75002 Pin No. 1 2 Terminal Pin No. Assignment (TB2) : SWITCHLAB MB310-75002 Assignment AC/N AC/L Pin No. 1 2 Assignment +V -V Block Diagram fosc : 39KHz(115VAC) 53KHz(230VAC) EMI FILTER & RECTIFIERS I/P RECTIFIERS & FILTER POWER SWITCHING +V -V DETECTION CIRCUIT O.L.P. PWM & PFC CONTROL O.C.P. O.V.P. Derating Curve Static Characteristics 100 100 90 80 80 70 LOAD (%) LOAD (%) 60 40 20 -30 -25 -5 0 15 30 40 AMBIENT TEMPERATURE ( ) 50 60 60 50 40 90 100 125 135 145 155 165 175 180 200 230 264 INPUT VOLTAGE (V) 60Hz File Name:PLC-30-SPEC 2012-03-12 PLC-30 30W Single Output LED Power Supply series Power Factor Characteristic Constant Current Mode PF 1 .0 0 0 .9 8 0 .9 6 0 .9 4 0 .9 2 0 .9 0 0 .8 8 0 .8 6 0 .8 4 0 .8 2 0 .8 0 0 .7 8 230V 115V 50% 60% 70% 80% 90% 100% (30W) LOAD EFFICIENCY vs LOAD (48V Model) PLC-30 series possess superior working efficiency that up to 85.5% can be reached in field applications. EFFICIENCY (%) 90 88 86 84 82 80 78 76 74 72 70 68 66 64 62 60 58 56 54 230V 115V 10% 20% 30% 40% 50% 60% 70% 80% 90% 100% LOAD DRIVING METHODS OF LED MODULE This LED power supply is suggested to work in constant current mode area (CC) to drive the LEDs. 100 Vo(%) Constant Current area 70 (max.) Hiccup Protection 50 100 Io (%) Typical LED power supply I-V curve File Name:PLC-30-SPEC 2012-03-12