New Product MUR140, MUR160 Vishay General Semiconductor Ultrafast Plastic Rectifier FEATURES • Glass passivated chip junction • Ultrafast reverse recovery time • Low forward voltage drop • Low leakage current • Low switching losses, high efficiency • High forward surge capability DO-204AC (DO-15) • Solder dip 275 °C max. 10 s, per JESD 22-B106 • Compliant to RoHS directive 2002/95/EC and in accordance to WEEE 2002/96/EC TYPICAL APPLICATIONS PRIMARY CHARACTERISTICS For use in high frequency rectification and freewheeling application in switching mode converters and inverters for consumer, computer and telecommunication. IF(AV) 1.0 A VRRM 400 V, 600 V IFSM 35 A MECHANICAL DATA trr 50 ns VF 1.05 V TJ max. 175 °C Case: DO-204AC (DO-15) Molding compound meets UL 94 V-0 flammability rating Base P/N-E3 - RoHS compliant, commercial grade Terminals: Matte tin plated leads, solderable J-STD-002 and JESD 22-B102 E3 suffix meets JESD 201 class 1A whisker test per Polarity: Color band denotes cathode end MAXIMUM RATINGS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL MUR140 MUR160 UNIT Maximum repetitive peak reverse voltage VRRM 400 600 V Working peak reverse voltage VRWM 400 600 V Maximum DC blocking voltage VDC 400 600 V Maximum average forward rectified current at TA = 120 °C IF(AV) 1.0 A Peak forward surge current 8.3 ms single half sine-wave superimposed on rated load IFSM 35 A TJ, TSTG - 65 to + 175 °C Operating junction and storage temperature range Document Number: 88684 Revision: 22-Oct-09 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 1 New Product MUR140, MUR160 Vishay General Semiconductor ELECTRICAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TJ = 25 °C Maximum instantaneous forward voltage IF = 1.0 A MUR140 TJ = 25 °C UNIT 1.25 VF (1) V TJ = 150 °C Maximum instantaneous reverse current at rated DC blocking voltage MUR160 1.05 5.0 IR (1) μA TJ = 150 °C 150 Maximum reverse recovery time IF = 0.5 A, IR = 1.0 A, Irr = 0.25 A trr 50 ns Maximum reverse recovery time IF = 1.0 A, dI/dt = 50 A/μs, VR = 30 V, Irr = 10 % IRM trr 75 ns Maximum forward recovery time IF = 1.0 A, dI/dt = 100 A/μs, recovery to 1.0 V tfr 50 ns Note (1) Pulse test: 300 μs pulse width, duty cycle ≤ 2 % THERMAL CHARACTERISTICS (TA = 25 °C unless otherwise noted) PARAMETER SYMBOL MUR140 RθJA (1) Typical thermal resistance, junction to ambient MUR160 50 UNIT °C/W Note Lead length = 3/8" on P.C.B. with 1.5" x 1.5" (38.1 mm x 38.1 mm) copper surface (1) ORDERING INFORMATION (Example) PREFERRED P/N UNIT WEIGHT (g) PREFERRED PACKAGE CODE BASE QUANTITY DELIVERY MODE MUR160-E3/54 0.41 54 4000 13" diameter paper tape and reel MUR160-E3/73 0.41 73 2000 Ammo pack packaging RATINGS AND CHARACTERISTICS CURVES (TA = 25 °C unless otherwise noted) 50 L = 3/8" P.C.B. with 1.5" x 1.5" (38.1 mm x 38.1 mm) Copper Pads 2.0 1.0 Peak Forward Surge Current (A) Average Forward Rectified Current (A) 3.0 40 30 20 10 0 0 0 25 50 75 100 125 150 175 1 10 100 Ambient Temperature (°C) Number of Cycles at 50 Hz Fig. 1 - Forward Current Derating Curve Fig. 2 - Maximum Non-Repetitive Peak Forward Surge Current www.vishay.com 2 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] Document Number: 88684 Revision: 22-Oct-09 New Product MUR140, MUR160 Vishay General Semiconductor 100 Junction Capacitance (pF) Instantaneous Forward Current (A) 100 TJ = 175 °C 10 TJ = 150 °C 1 0.1 TJ = 25 °C f = 1.0 MHz Vsig = 50 mVp-p 10 TJ = 25 °C 0.01 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1 0.1 1.8 1 10 100 Instantaneous Forward Voltage (V) Reverse Voltage (V) Fig. 3 - Typical Instantaneous Forward Characteristics Fig. 5 - Typical Junction Capacitance Instantaneous Reverse Leakage Current (μA) 1000 TJ = 175 °C 100 TJ = 150 °C 10 1 TJ = 25 °C 0.1 0.01 0 20 40 60 80 100 Percent of Rated Peak Reverse Voltage (%) Fig. 4 - Typical Reverse Leakage Characteristics PACKAGE OUTLINE DIMENSIONS in inches (millimeters) DO-204AC (DO-15) 0.034 (0.86) 0.028 (0.71) DIA. 1.0 (25.4) MIN. 0.300 (7.6) 0.230 (5.8) 0.140 (3.6) 0.104 (2.6) DIA. 1.0 (25.4) MIN. Document Number: 88684 Revision: 22-Oct-09 For technical questions within your region, please contact one of the following: [email protected], [email protected], [email protected] www.vishay.com 3 Legal Disclaimer Notice Vishay Disclaimer ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE. Vishay Intertechnology, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained in any datasheet or in any other disclosure relating to any product. Vishay makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the continuing production of any product. To the maximum extent permitted by applicable law, Vishay disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability. Statements regarding the suitability of products for certain types of applications are based on Vishay’s knowledge of typical requirements that are often placed on Vishay products in generic applications. Such statements are not binding statements about the suitability of products for a particular application. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application. Parameters provided in datasheets and/or specifications may vary in different applications and performance may vary over time. All operating parameters, including typical parameters, must be validated for each customer application by the customer’s technical experts. Product specifications do not expand or otherwise modify Vishay’s terms and conditions of purchase, including but not limited to the warranty expressed therein. Except as expressly indicated in writing, Vishay products are not designed for use in medical, life-saving, or life-sustaining applications or for any other application in which the failure of the Vishay product could result in personal injury or death. Customers using or selling Vishay products not expressly indicated for use in such applications do so at their own risk and agree to fully indemnify and hold Vishay and its distributors harmless from and against any and all claims, liabilities, expenses and damages arising or resulting in connection with such use or sale, including attorneys fees, even if such claim alleges that Vishay or its distributor was negligent regarding the design or manufacture of the part. Please contact authorized Vishay personnel to obtain written terms and conditions regarding products designed for such applications. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of Vishay. Product names and markings noted herein may be trademarks of their respective owners. Document Number: 91000 Revision: 11-Mar-11 www.vishay.com 1