BEL 0RHB

ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
0RHB-40TRxx
RoHS Compliant
Rev.C
•
Isolated
•
Fixed Switching Frequency (110 kHz)
•
High Efficiency
•
Output Short Circuit Protection
•
Basic Insulation
•
Input Under/Over Voltage Protection
•
Low Cost
•
Over Temperature Protection
•
Low THD Sine Wave Output
•
CNT On/Off Logic
•
Excellent Thermal Performance
•
External Output Voltage Control 65 Vrms - 95 Vrms
•
External Digital Frequency Selection 17.5 Hz, 20 Hz, 25 Hz and 50 Hz
•
Overload Protection with Advanced Output Power Control
Description
The 0RHB-40TRxx is an isolated dc/ac ring generator that operates from a nominal 48 Vdc source. This unit
provides up to 40 W output power. It is designed to be highly efficient and low cost in a half-brick package.
Part Selection
Output Voltage
Input Voltage
65 Vac - 95 Vac
36 Vdc - 75 Vdc
Max. Output
Power
40 W
65 Vac - 95 Vac
36 Vdc - 75 Vdc
40 W
Typical
Efficiency
85%
Model Number
Active High
0RHB-40TRG0
Model Number
Active Low
0RHB-40TRGL
85%
0RHB-40TRH0
0RHB-40TRHL
Notes: 1. 0RHB-40TRGx indicates application 1, 0RHB-40TRHx indicates application 2, details please see page 5.
2. Add “G” suffix at the end of the model number to indicate Tray Packaging.
3. All part numbers above indicate RoHS 6. Change the second letter "R" to "7" for RoHS 5 part numbers.
Absolute Maximum Ratings
Parameter
Input Voltage (continuous)
I/O Isolation Voltage
Min
-0.3 V
-
Typ
-
Max
80 V
1500 Vac
Ambient Temperature
-40 °C
-
85 °C
Storage Temperature
-50 °C
-
115 °C
Notes
Input Specifications
Parameter
Min
36 V
Typ
48 V
Max
75 V
Input Current (full load)
-
-
1.5 A
Input Current (no load)
-
-
60 mA
Input Voltage
Input Reflected Ripple Current (pk-pk)
-
-
150 mA
Turn-on Voltage Threshold
-
33 V
-
Under Voltage Threshold
-
-
32 V
Over Voltage Threshold
-
-
90 V
Notes
Tested with simulated source impedance
of 10 uH, 5 Hz to 20 MHz; use a 100 uF
/100 V electrolytic capacitor with ESR = 1
ohm max at 200 kHz at 25 °C.
Note: All specifications are typical at 25 °C unless otherwise stated.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Output Specifications
Parameter
Min
Output Voltage Set Point
Output Frequency
Typ
Max
92 V
95 V
98 V
f-1.0 Hz
f Hz
f+1.0 Hz
Notes
Vin=48 V, Io=50% load. Trim pin
is connected to GND.
Load Regulation
-
1%Vo
2%Vo
Line Regulation
-
0.5%Vo
1%Vo
Regulation Over Temperature
(-40deg.C - 85deg.C)
-
-
0.05%Vo/C
Voltage Accuracy
-
3%Vo
5%Vo
Frequency Accuracy
-
-
3%Vo
THD
-
-
5%
Output Current Range(95 Vac)
0 mA
-
420 mA
Output Power Limit
-
50 W
-
Turn on Time
-
-
1000 mS
Hiccup mode
Note: All specifications are typical at nominal input, full load at 25 °C unless noted.
General Specifications
Parameter
Efficiency
Switching Frequency
Isolation capacitance
Output Voltage Trim Range
Over Temperature Protection
Min
Typ
Max
83%
85%
-
100 kHz
110 kHz
120 kHz
-
1500 pF
-
65 Vac
-
95 Vac
-
125 °C
-
MTBF
Notes
Vin=48 V, full load , Ta=25°C
Calculated Per Bell Core SR-332 (IO =
80%load; Ta = 25 °C)
2,062,694 hours
Dimensions
Inches
millimeters
Weight
-
2.28 x 2.40 x 0.50
57.91 x 60.96 x 12.70
66 g
-
Note: All specifications are typical at 25 °C unless otherwise stated.
Control Specifications
Parameter
Min
Typ
Max
36 V
-
75 V
-0.7 V
-
30 V
36 V
-
75 V
-0.7 V
-
30 V
0 mA
-
2 mA
Notes
CNT On/Off
Signal High (Unit On)
Signal Low (Unit Off)
Signal High (Unit Off)
Signal Low (Unit On)
Current Source/Sink
Active High
Active Low
The CNT pin open, Unit on.
The CNT pin open, Unit off.
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Output Trim Equations
Equations for calculating the trim resistor is shown below. The Roac resistor should be connected between the
Trim pin and Gnd pin.
Roac =
Vout
1292 / 23
× 4.7 − 6.8( KΩ)
Vo − 1292 / 23
Module
Trim
Roac
Gnd
Roac(kΩ)
56 V
65 V
70 V
75 V
80 V
85 V
90 V
95 V
Open
23.113
12.296
7.224
4.281
2.359
1.005
0
Efficiency Data
Efficiency Curve
95.0%
Efficiency
90.0%
85.0%
36 V
48 V
75 V
80.0%
75.0%
70.0%
65.0%
60.0%
10
20
30
40
Output Power(W)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Thermal Derating Curves
With maximum junction temperature of semiconductors derated to 120 degree C.
Vin=48 V
Frequency Setting
Output Frequency
(Hz)
OPTF1
OPTF2
17.5
20
25
50
0
0
1
1
0
1
0
1
OPTF1 and OPTF2:
0: Connected to GND
1: Open
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Typical Application
Typical Application 1 (0RHB-40TRGx)
Output AC is superimposed on DC bias – A single DC power supply is used for the Ring Generator feeding and
for the output biasing.
0RHB -40TRGx
+
-48V Rtn
Vo1(~) 10
1 V(+)
12uH /3A
TRIM 9
2 CNT
220 uF/100 V 220uF/100 V
Telephone
Ports
OPTF 1 8
OPTF2 7
3 CASE
220 uF /100V
0V
-48V
GND 6
4 V(-)
-
Vo2(~) 5
-48V
Typical Application 2 (0RHB-40TRHx)
Output AC is superimposed on DC bias – Two DC power supplies are used, one for the Ring Generator feeding
and another for the output biasing.
0RHB-40TRHx
+
-48V Rtn
1 V(+)
Vo1(~) 10
12 uH/3 A
TRIM 9
2 CNT
220 uF/100V 220 uF/100 V
220 uF/100 V
3 CASE
OPTF2 7
0V
GND 6
4 V(-)
-48V
OPTF 1 8
-48V
Telephone
Ports
Vo2(~) 5
DC Bias
48V
-
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
Mechanical Outline
Pin Connections
pin
function
pin
function
pin
function
1
2
3
4
Vin(+)
CNT
Case
Vin(-)
5
6
7
Vo2(~)
GND
OPTF2
8
9
10
OPTF1
Trim
Vo1(~)
Bel Fuse Inc. 206 Van Vorst Street, Jersey City, NJ 07302 • Tel 201-432-0463 • Fax 201-432-9542 • www.belfuse.com
ISOLATED DC/AC CONVERTER
36 Vdc - 75 Vdc Input, 65 Vac - 95 Vac 17.5, 20, 25, 50 Hz/40 W Output
INSTALLATION INSTRUCTION
1) The DC-AC Converter can be operated at an ambient temperature up to 85°C maximum.
2) The DC-AC Converter is a built-in component. During installation into certain equipment the relevant
requirements of EN 60950-1:2001 + A11 and IEC 60950-1:2001 shall be maintained.
3) The creepage distances, clearances and thickness of insulation between unearthed hazardous voltage input
and hazardous voltage output circuits have complied with basic insulation requirements according to EN
60950-1:2001 + A11 and IEC 60950-1:2001.
4) The output ratings as shown on the label must not be exceeded.
5) The equipment is to be supplied from a DC source which is separated from AC mains by double or reinforced
insulation, or by basic insulation and suitable earthing providing equivalent protection.
6) The equipment is intended to be installed into a class I or class II system, when installed into class I system,
protective earth has to be reliably identified and suitable external protection devices have to be provided in
the final system.
7) The equipment shall be installed with an external forced air-cooling according to installation instruction
accompanied with the unit. The airflow direction is towards the side of the equipment.
RoHS Compliance
Complies with the European Directive 2002/95/EC, calling for the elimination of lead and
other hazardous substances from electronic products.
©2008 Bel Fuse Inc. Specifications subject to change without notice. 090508
CORPORATE
FAR EAST
EUROPE
Bel Fuse Inc.
206 Van Vorst Street
Jersey City, NJ 07302
Tel 201-432-0463
Fax 201-432-9542
www.belfuse.com
Bel Fuse Ltd.
8F/ 8 Luk Hop Street
San Po Kong
Kowloon, Hong Kong
Tel 852-2328-5515
Fax 852-2352-3706
www.belfuse.com
Bel Fuse Europe Ltd.
Preston Technology Management Centre
Marsh Lane, Suite G7, Preston
Lancashire, PR1 8UD, U.K.
Tel 44-1772-556601
Fax 44-1772-888366
www.belfuse.com