FEATURES High efficiency: 92% @48V/3.2A Size: 57.9x61.0x9.8mm (2.28” x2.40” x0.39”) (without Heat Spreader) 57.9x61.0x12.7mm (2.28” x2.40” x0.50”) (with Heat Spreader) Standard footprint Industry standard pin out Fixed frequency operation Input UVLO, Output OCP, OVP, OTP 2250V isolation and basic insulation No minimum load required ISO 9001, TL 9000, ISO 14001, QS9000, OHSAS18001 certified manufacturing facility UL/cUL 60950-1 (US & Canada) Recognized Delphi Series H48SA, 150W Half Brick Family DC/DC Power Modules: 36~75V in, 48V/3.2A out The Delphi H48SA series half brick, 36~75V input, single output, isolated DC/DC converter is the latest offering from a world leader in power system and technology and manufacturing ― Delta Electronics, OPTIONS Positive, negative, or no On/Off OTP and Output OVP, OCP mode, Inc. This product family operates from a wide 36~75V input voltage range and provides up to 150 watts of power in an industry standard Auto-restart or latch-up footprint and pin out. With creative design technology and optimization of component placement, these converters possess outstanding electrical and thermal performances, as well as extremely high reliability under highly stressful operating conditions. All models are fully protected from abnormal input/output voltage, current, and temperature conditions. The Delphi Series converters meet all safety requirements with basic insulation. DATASHEET DS_H48SA48003_09292012 APPLICATIONS Telecom / Datacom Wireless Networks Optical Network Equipment Server and Data Storage Industrial / Testing Equipment TECHNICAL SPECIFICATIONS (TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted; PARAMETER NOTES and CONDITIONS H48SA48003 (Standard) Min. ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous Transient (100ms) Operating Hot Spot Temperature (Without Heat Spreader) Operating Case Temperature (With Heat Spreader) Storage Temperature Input/Output Isolation Voltage INPUT CHARACTERISTICS Operating Input Voltage Input Under-Voltage Lockout Turn-On Voltage Threshold Turn-Off Voltage Threshold Lockout Hysteresis Voltage Maximum Input Current No-Load Input Current Off Converter Input Current Inrush Current(I2t) Input Reflected-Ripple Current Input Voltage Ripple Rejection OUTPUT CHARACTERISTICS Output Voltage Set Point Output Voltage Regulation Over Load Over Line Over Temperature Total Output Voltage Range Output Voltage Ripple and Noise Peak-to-Peak RMS Operating Output Current Range Output Over DC Current protection(hiccup mode) DYNAMIC CHARACTERISTICS Output Voltage Current Transient Positive Step Change in Output Current Negative Step Change in Output Current Settling Time (within 1% Vout nominal) Turn-On Transient Start-Up Time, From On/Off Control Start-Up Time, From Input External Output Capacitance EFFICIENCY 100% Load 60% Load ISOLATION CHARACTERISTICS Input to Output Isolation Resistance Isolation Capacitance FEATURE CHARACTERISTICS Switching Frequency ON/OFF Control, Negative Remote On/Off logic Logic Low (Module On) Logic High (Module Off) ON/OFF Control, Positive Remote On/Off logic Logic Low (Module Off) Logic High (Module On) ON/OFF Current (for both remote on/off logic) Leakage Current (for both remote on/off logic) Output Voltage Trim Range Output Over-Voltage Protection (Latch Mode) GENERAL SPECIFICATIONS MTBF Weight for openframe Weight for with heatspreader Over-Temperature Shutdown ( Without Heat Spreader ) Over-Temperature Shutdown ( With Heat Spreader) DS_H48SA48003_09292012 100ms Please refer to Figure 20 Please refer to Figure 22 Typ. -40 -40 -55 1 minute 36 48 32 29 2 100% Load, 36Vin Output Voltage 10% Low 80 100 123 100 125 2250 Vdc Vdc °C °C °C Vdc 75 Vdc 35 32 4 5.5 Vdc Vdc Vdc A mA mA A2s mA dB 1 150 P-P thru 12µH inductor, 5Hz to 20MHz 120 Hz Io=Io,min to Io,max Vin=36V to 75V Tc=-40°C to 100°C over sample load, line and temperature 5Hz to 20MHz bandwidth, Full load Full load, 470µF electrolytic load cap Units 60 8 Vin=48V Vin=48V, Io=Io.max, Tc=25°C Max. 60 47.23 48.00 -3 0 3.6 48.77 Vdc 1 1 0.02 3 %Vo %Vo %Vo/°C %Vo 250 mV mV A A 3.2 5.5 48Vin, 0.1A/µs 25% Io.max to 50% Io.max 50% Io.max to 25% Io.max 5 5 %Vo %Vo µs Full load; 5% overshoot of Vout at startup 100 100 1200 ms ms µF 47 Vin=48V Vin=48V 92.0 92.0 % % 2250 1000 Vdc MΩ pF 350 kHz 10 Von/off at Ion/off=1.0mA Von/off at Ion/off=0.0 µA -0.7 3.5 1.2 15 V V Von/off at Ion/off=1.0mA Von/off at Ion/off=0.0 µA Ion/off at Von/off=0.0V Logic High, Von/off=15V Pout <= max rated power,Iout <= max Io Over full temp range; % of nominal Vout 0 3.5 1.2 15 1.5 80 56 110 59 V V mA uA %Vo V Io=80% of Io, max; Tc=40°C Please refer to Figure 20 Please refer to Figure 22 3.4 44.8 75.0 136 112 M hours grams grams °C °C 2 ELECTRICAL CHARACTERISTICS CURVES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation vs. load current for minimum, nominal, and maximum input voltage at 25°C. 6.0 5.5 INPUT CURRENT (A) 1 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.5 1.0 0.5 0.0 30 35 40 45 50 55 60 65 70 75 INPUT VOLTAGE (V) Figure 3: Typical full load input characteristics at room temperature. DS_H48SA48003_09292012 3 ELECTRICAL CHARACTERISTICS CURVES For Positive Remote On/Off Logic Figure 4: Turn-on transient at full rated load current (20ms/div). Top Trace: Vout; 10V/div; Bottom Trace: ON/OFF input: 5V/div. Figure 5: Turn-on transient at zero load current (20 ms/div). Top Trace: Vout: 10V/div; Bottom Trace: ON/OFF input:5V/div. For Input Voltage Start up Figure 6:Turn-on transient at full rated load current (20 ms/div). Top Trace: Vout; 10V/div; Bottom Trace: input voltage: 50V/div. DS_H48SA48003_09292012 Figure 7: Turn-on transient at zero load current (20 ms/div). Top Trace: Vout; 10V/div; Bottom Trace: input voltage: 50V/div. 4 ELECTRICAL CHARACTERISTICS CURVES Figure 8: Output voltage response to step-change in load current (50%-25% of Io, max; di/dt = 0.1A/µs). Load cap: 47µF aluminum capacitor and 1µF ceramic capacitor. TOP Trace: Vout (1V/div), Bottom Trace: Iout (1A/div), Scope measurement should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module. Figure 9: Output voltage response to step-change in load current (25%-50% of Io, max; di/dt = 0.1A/µs). Load cap: 47µF aluminum capacitor and 1µF ceramic capacitor. TOP Trace: Vout (1V/div), Bottom Trace: Iout (1A/div), Scope measurement should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module. Figure 10: Test set-up diagram showing measurement points for Input Terminal Ripple Current and Input Reflected Ripple Current. Note: Measured input reflected-ripple current with a simulated source Inductance (LTEST) of 12 µH. Capacitor Cs offset possible battery impedance. Measure current as shown above. Figure 11: Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 12µH source impedance and 100µF electrolytic capacitor (200mA/div,2us/div). DS_H48SA48003_09292012 5 ELECTRICAL CHARACTERISTICS CURVES Figure 12: Input reflected ripple current, is, through a 12µH source inductor at nominal input voltage and rated load current (20mA/div,2us/div). Figure 13: Output voltage noise and ripple measurement test setup. Figure 14: Output voltage ripple at nominal input voltage and rated load current (Io=3.2A) (50mV/div,2us/div) Load capacitance: 1µF ceramic capacitor and 470µF electrolytic capacitor. Bandwidth: 20MHz. Scope measurements should be made using a BNC cable (length shorter than 20 inches). Position the load between 51 mm to 76 mm (2 inches to 3 inches) from the module. Figure 15: Output voltage vs. load current showing typical current limit curves and converter shutdown points. DS_H48SA48003_09292012 6 DESIGN CONSIDERATIONS Input Source Impedance The impedance of the input source connecting to the DC/DC power modules will interact with the modules and affect the stability. A low ac-impedance input source is recommended. If the source inductance is more than a few µH, we advise adding a 10µF to 100µF electrolytic capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to the input of the module to improve the stability. Layout and EMC Considerations Delta’s DC/DC power modules are designed to operate in a wide variety of systems and applications. For design assistance with EMC compliance and related PWB layout issues, please contact Delta’s technical support team. An external input filter module is available for easier EMC compliance design. Application notes to assist designers in addressing these issues are pending release. Safety Considerations The power module must be installed in compliance with the spacing and separation requirements of the end-user’s safety agency standard, i.e., UL60950-1, CSA C22.2 NO. 60950-1 2nd and IEC 60950-1 2nd : 2005 and EN 60950-1 2nd: 2006+A11+A1: 2010, if the system in which the power module is to be used must meet safety agency requirements. When installed into a Class II equipment (without grounding), spacing consideration should be given to the end-use installation, as the spacing between the module and mounting surface have not been evaluated. The power module has extra-low voltage (ELV) outputs when all inputs are ELV. This power module is not internally fused. To achieve optimum safety and system protection, an input line fuse is highly recommended. The safety agencies require a Fast-acting fuse with 20A maximum rating to be installed in the ungrounded lead. A lower rated fuse can be used based on the maximum inrush transient energy and maximum input current. Soldering and Cleaning Considerations Post solder cleaning is usually the final board assembly process before the board or system undergoes electrical testing. Inadequate cleaning and/or drying may lower the reliability of a power module and severely affect the finished circuit board assembly test. Adequate cleaning and/or drying is especially important for un-encapsulated and/or open frame type power modules. For assistance on appropriate soldering and cleaning procedures, please contact Delta’s technical support team. Basic insulation based on 75 Vdc input is provided between the input and output of the module for the purpose of applying insulation requirements when the input to this DC-to-DC converter is identified as TNV-2 or SELV. An additional evaluation is needed if the source is other than TNV-2 or SELV. When the input source is SELV circuit, the power module meets SELV (safety extra-low voltage) requirements. If the input source is a hazardous voltage which is greater than 60 Vdc and less than or equal to 75 Vdc, for the module’s output to meet SELV requirements, all of the following must be met: The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. A SELV reliability test is conducted on the system where the module is used, in combination with the module, to ensure that under a single fault, hazardous voltage does not appear at the module’s output. DS_H48SA48003_09292012 7 FEATURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modules will automatically shut down (hiccup mode). For negative logic, if the remote on/off feature is not used, please short the on/off pin to Vi (-). For positive logic, if the remote on/off feature is not used, please leave the on/off pin to floating. The modules will try to restart after shutdown. If the overload condition still exists, the module will shut down again. This restart trial will continue until the overload condition is corrected. Over-Voltage Protection The modules include an internal output over-voltage protection circuit, which monitors the voltage on the output terminals. The default OVP operation is latch mode. Under latch mode, If this voltage exceeds the over-voltage set point, the module will shut down and latch off. The over-voltage latch is reset by either cycling the input power or by toggling the on/off signal for one second. Also, an optional hiccup mode for OVP is available. under hiccup mode, the modules will try to restart after shutdown. If the over voltage condition still exists, the module will shut down again. This restart trial will continue until the over-voltage condition is corrected. Figure 16: Remote on/off implementation Output Voltage Adjustment (TRIM) To increase or decrease the output voltage set point, the modules may be connected with an external resistor between the TRIM pin and either Vout1 (+) or Vout (-). The TRIM pin should be left open if this feature is not used. Over-Temperature Protection The over-temperature protection consists of circuitry that provides protection from thermal damage. If the temperature exceeds the over-temperature threshold the module will shut down. The module will try to restart after shutdown. If the over-temperature condition still exists during restart, the module will shut down again. This restart trial will continue until the temperature is within specification. Remote On/Off The remote on/off feature on the module can be either negative or positive logic. Negative logic turns the module on during a logic low and off during a logic high. Positive logic turns the modules on during a logic high and off during a logic low. Remote on/off can be controlled by an external switch between the on/off terminal and the Vi(-) terminal. The switch can be an open collector or open drain. DS_H48SA48003_09292012 Figure 17: Circuit configuration for trim-up (increase output voltage) If the external resistor is connected between the TRIM and sense (+) pin, the output voltage set point increases (Fig. 17). The external resistor value required to obtain output voltage change to Vo is defined as: Note:Vn is normal output voltage. Ex.When Trim-up10%,Vo is (10%+1) *Vn =1.1*48 = 52.8V Rtrim −up = 1 − ( 2.5 − 1.2 * 48) * (52.8 / 48) = 616.1KΩ (52.8 / 48) − 1 8 THERMAL CONSIDERATIONS Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer. Figure 18: Circuit configuration for trim-down (decrease output voltage) If the external resistor is connected between the TRIM and sense(-), Vout decreases (Fig. 18). The external resistor value required to obtain output voltage change to Vo is defined as: Note:Vn is normal output voltage. Ex. When Trim-down 10%,Vo is Vn-10%*Vn = 48-48*0.1 = 43.2V Rtrim−down = 2.5 * ( 43.2 / 48) − 1 = 12.5( KΩ) 1 − ( 43.2 / 48) Hence, the choice of equipment to characterize the thermal performance of the power module is a wind tunnel. Thermal Testing Setup Delta’s DC/DC power modules are characterized in heated vertical wind tunnels that simulate the thermal environments encountered in most electronics equipment. This type of equipment commonly uses vertically mounted circuit cards in cabinet racks in which the power modules are mounted. The following figure shows the wind tunnel characterization setup. The power module is mounted on a test PWB and is vertically positioned within the wind tunnel. The space between the neighboring PWB and the top of the power module is constantly kept at 6.35mm (0.25’’). PWB FACING PWB When using trim-up, the output voltage of the module is usually increased, which increases the power output of the module with the same output current. Care should be taken to ensure that the maximum output power of the module remains at or below the maximum rated power. MODULE AIR VELOCITY AND AMBIENT TEMPERATURE MEASURED BELOW THE MODULE 50.8 (2.0”) AIR FLOW 12.7 (0.5”) Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches) Figure 19: Wind tunnel test setup Thermal Derating Heat can be removed by increasing airflow over the module. To enhance system reliability, the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit may be affected. DS_H48SA48003_09292012 9 THERMAL CURVES (WITHOUT HEAT SPREADER) THERMAL CURVES (WITH HEAT SPREADER) Figure 20: Temperature measurement location * The allowed maximum hot spot temperature is defined at 123℃ Output Current (A) H48SA48003(Standard) Output Current vs. Ambient Temperature and Air Velocity @Vin = 48V (Either Orientation) 3.2 Figure 22: Temperature measurement location * The allowed maximum hot spot temperature is defined at 100℃ Output Current (A) H48SA48003(Standard) Outp ut Current vs. Ambient Temperature a nd Air Velocity @Vin = 48 V (Eith er Orientation;With H eatsprea der) 3.2 2.8 2.8 Natural Convection Natu ra l Convectio n 2.4 2.4 100LFM 100LFM 2.0 200LFM 1.6 200L FM 2.0 300LFM 1.6 300LFM 400LFM 400LFM 1.2 1.2 0.8 0.8 0.4 0.4 0.0 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (℃) 0.0 25 30 35 40 45 50 55 60 65 70 75 80 85 Ambient Temperature (℃) Figure 21: Output current vs. ambient temperature and air velocity Figure 23: Output current vs. ambient temperature and air velocity @Vin=48V(Either Orientation, Without Heat spreader) @Vin=48V(Either Orientation, With Heat spreader) DS_H48SA48003_09292012 10 MECHANICAL DRAWING (WITH HEAT SPREADER) DS_H48SA48003_09292012 11 MECHANICAL DRAWING (WITHOUT HEAT SPREADER) Pin No. 1 2 3 4 5 6 7 8 9 Name Function +Vin ON/OFF Case -Vin -Vout -Sense Trim +Sense +Vout Positive input voltage Remote ON/OFF Optional Negative input voltage Negative output voltage Negative remote sense Output voltage trim Positive remote sense Positive output voltage Pin Specification: Pins 1-4,6-8 Pins 5 & 9 1.00mm (0.040”) diameter 2.00mm (0.079”) diameter All pins are copper with matte Tin plated. DS_H48SA48003_09292012 12 PART NUMBERING SYSTEM H 48 S A 480 03 P N H Form Input Number of Product Output Output ON/OFF Pin Option Code Factor Voltage Outputs Series Voltage Current Logic Length S - Single A - Advanced 480 - 48V 03 - 3.2A H - Half Brick 48 36~75V P- Positive N- Negative N - 0.145” R - 0.170’’ Space- RoHs 5/6 F- RoHS 6/6 (Lead Free) A – standard function H - with Heatspreader MODEL LIST MODEL NAME H48SA48003PN H INPUT 36V~75V OUTPUT 5.5A 48V EFF @ 100% LOAD 3.2A 92.0% Default remote on/off logic is negative and pin length is 0.145’’. * For modules with through-hole pins and the optional heat spreader, they are intended for wave soldering assembly onto system boards; please do not subject such modules through reflow Temperature profile. CONTACT: www.delta.com.tw/dcdc USA: Telephone: East Coast: 978-656-3993 West Coast: 510-668-5100 Fax: (978) 656 3964 Email: [email protected] Europe: Phone: +41 31 998 53 11 Fax: +41 31 998 53 53 Email: [email protected] Asia & the rest of world: Telephone: +886 3 4526107 ext 6220~6224 Fax: +886 3 4513485 Email: [email protected] WARRANTY Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request from Delta. Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any time, without notice. DS_H48SA48003_09292012 13