DELTA H48SA48003NRFH

FEATURES
Š
Š
High efficiency: 92% @48V/3.2A
Size:
57.9x61.0x9.8mm (2.28” x2.40” x0.39”)
(without Heat Spreader)
57.9x61.0x12.7mm (2.28” x2.40” x0.50”)
(with Heat Spreader)
Š
Standard footprint
Š
Industry standard pin out
Š
Fixed frequency operation
Š
Input UVLO, Output OCP, OVP, OTP
Š
2250V isolation and basic insulation
Š
No minimum load required
Š
ISO 9001, TL 9000, ISO 14001, QS9000,
OHSAS18001 certified manufacturing facility
Š
UL/cUL 60950-1 (US & Canada) Recognized
Delphi Series H48SA, 150W Half Brick Family
DC/DC Power Modules: 36~75V in, 48V/3.2A out
The Delphi H48SA series half brick, 36~75V input, single output,
isolated DC/DC converter is the latest offering from a world leader in
power system and technology and manufacturing ― Delta Electronics,
OPTIONS
Š
Positive, negative, or no On/Off
Š
OTP and Output OVP, OCP mode,
Inc. This product family operates from a wide 36~75V input voltage
range and provides up to 150 watts of power in an industry standard
Auto-restart or latch-up
footprint and pin out. With creative design technology and optimization
of component placement, these converters possess outstanding
electrical and thermal performances, as well as extremely high reliability
under highly stressful operating conditions. All models are fully
protected from abnormal input/output voltage, current, and temperature
conditions. The Delphi Series converters meet all safety requirements
with basic insulation.
DATASHEET
DS_H48SA48003_09292012
APPLICATIONS
Š
Telecom / Datacom
Š
Wireless Networks
Š
Optical Network Equipment
Š
Server and Data Storage
Š
Industrial / Testing Equipment
TECHNICAL SPECIFICATIONS
(TA=25°C, airflow rate=300 LFM, Vin=48Vdc, nominal Vout unless otherwise noted;
PARAMETER
NOTES and CONDITIONS
H48SA48003 (Standard)
Min.
ABSOLUTE MAXIMUM RATINGS
Input Voltage
Continuous
Transient (100ms)
Operating Hot Spot Temperature (Without Heat Spreader)
Operating Case Temperature (With Heat Spreader)
Storage Temperature
Input/Output Isolation Voltage
INPUT CHARACTERISTICS
Operating Input Voltage
Input Under-Voltage Lockout
Turn-On Voltage Threshold
Turn-Off Voltage Threshold
Lockout Hysteresis Voltage
Maximum Input Current
No-Load Input Current
Off Converter Input Current
Inrush Current(I2t)
Input Reflected-Ripple Current
Input Voltage Ripple Rejection
OUTPUT CHARACTERISTICS
Output Voltage Set Point
Output Voltage Regulation
Over Load
Over Line
Over Temperature
Total Output Voltage Range
Output Voltage Ripple and Noise
Peak-to-Peak
RMS
Operating Output Current Range
Output Over DC Current protection(hiccup mode)
DYNAMIC CHARACTERISTICS
Output Voltage Current Transient
Positive Step Change in Output Current
Negative Step Change in Output Current
Settling Time (within 1% Vout nominal)
Turn-On Transient
Start-Up Time, From On/Off Control
Start-Up Time, From Input
External Output Capacitance
EFFICIENCY
100% Load
60% Load
ISOLATION CHARACTERISTICS
Input to Output
Isolation Resistance
Isolation Capacitance
FEATURE CHARACTERISTICS
Switching Frequency
ON/OFF Control, Negative Remote On/Off logic
Logic Low (Module On)
Logic High (Module Off)
ON/OFF Control, Positive Remote On/Off logic
Logic Low (Module Off)
Logic High (Module On)
ON/OFF Current (for both remote on/off logic)
Leakage Current (for both remote on/off logic)
Output Voltage Trim Range
Output Over-Voltage Protection (Latch Mode)
GENERAL SPECIFICATIONS
MTBF
Weight for openframe
Weight for with heatspreader
Over-Temperature Shutdown ( Without Heat Spreader )
Over-Temperature Shutdown ( With Heat Spreader)
DS_H48SA48003_09292012
100ms
Please refer to Figure 20
Please refer to Figure 22
Typ.
-40
-40
-55
1 minute
36
48
32
29
2
100% Load, 36Vin
Output Voltage 10% Low
80
100
123
100
125
2250
Vdc
Vdc
°C
°C
°C
Vdc
75
Vdc
35
32
4
5.5
Vdc
Vdc
Vdc
A
mA
mA
A2s
mA
dB
1
150
P-P thru 12µH inductor, 5Hz to 20MHz
120 Hz
Io=Io,min to Io,max
Vin=36V to 75V
Tc=-40°C to 100°C
over sample load, line and temperature
5Hz to 20MHz bandwidth, Full load
Full load, 470µF electrolytic load cap
Units
60
8
Vin=48V
Vin=48V, Io=Io.max, Tc=25°C
Max.
60
47.23
48.00
-3
0
3.6
48.77
Vdc
1
1
0.02
3
%Vo
%Vo
%Vo/°C
%Vo
250
mV
mV
A
A
3.2
5.5
48Vin, 0.1A/µs
25% Io.max to 50% Io.max
50% Io.max to 25% Io.max
5
5
%Vo
%Vo
µs
Full load; 5% overshoot of Vout at startup
100
100
1200
ms
ms
µF
47
Vin=48V
Vin=48V
92.0
92.0
%
%
2250
1000
Vdc
MΩ
pF
350
kHz
10
Von/off at Ion/off=1.0mA
Von/off at Ion/off=0.0 µA
-0.7
3.5
1.2
15
V
V
Von/off at Ion/off=1.0mA
Von/off at Ion/off=0.0 µA
Ion/off at Von/off=0.0V
Logic High, Von/off=15V
Pout <= max rated power,Iout <= max Io
Over full temp range; % of nominal Vout
0
3.5
1.2
15
1.5
80
56
110
59
V
V
mA
uA
%Vo
V
Io=80% of Io, max; Tc=40°C
Please refer to Figure 20
Please refer to Figure 22
3.4
44.8
75.0
136
112
M hours
grams
grams
°C
°C
2
ELECTRICAL CHARACTERISTICS CURVES
Figure 1: Efficiency vs. load current for minimum, nominal, and
maximum input voltage at 25°C.
Figure 2: Power dissipation vs. load current for minimum,
nominal, and maximum input voltage at 25°C.
6.0
5.5
INPUT CURRENT (A) 1
5.0
4.5
4.0
3.5
3.0
2.5
2.0
1.5
1.0
0.5
0.0
30
35
40
45
50
55
60
65
70
75
INPUT VOLTAGE (V)
Figure 3: Typical full load input characteristics at room
temperature.
DS_H48SA48003_09292012
3
ELECTRICAL CHARACTERISTICS CURVES
For Positive Remote On/Off Logic
Figure 4: Turn-on transient at full rated load current (20ms/div).
Top Trace: Vout; 10V/div; Bottom Trace: ON/OFF input: 5V/div.
Figure 5: Turn-on transient at zero load current (20 ms/div).
Top Trace: Vout: 10V/div; Bottom Trace: ON/OFF input:5V/div.
For Input Voltage Start up
Figure 6:Turn-on transient at full rated load current (20 ms/div).
Top Trace: Vout; 10V/div; Bottom Trace: input voltage: 50V/div.
DS_H48SA48003_09292012
Figure 7: Turn-on transient at zero load current (20 ms/div).
Top Trace: Vout; 10V/div; Bottom Trace: input voltage: 50V/div.
4
ELECTRICAL CHARACTERISTICS CURVES
Figure 8: Output voltage response to step-change in load
current (50%-25% of Io, max; di/dt = 0.1A/µs). Load cap: 47µF
aluminum capacitor and 1µF ceramic capacitor. TOP Trace:
Vout (1V/div), Bottom Trace: Iout (1A/div), Scope measurement
should be made using a BNC cable (length shorter than 20
inches). Position the load between 51 mm to 76 mm (2 inches
to 3 inches) from the module.
Figure 9: Output voltage response to step-change in load
current (25%-50% of Io, max; di/dt = 0.1A/µs). Load cap: 47µF
aluminum capacitor and 1µF ceramic capacitor. TOP Trace:
Vout (1V/div), Bottom Trace: Iout (1A/div), Scope
measurement should be made using a BNC cable (length
shorter than 20 inches). Position the load between 51 mm to
76 mm (2 inches to 3 inches) from the module.
Figure 10: Test set-up diagram showing measurement points
for Input Terminal Ripple Current and Input Reflected Ripple
Current.
Note: Measured input reflected-ripple current with a simulated
source Inductance (LTEST) of 12 µH. Capacitor Cs offset
possible battery impedance. Measure current as shown above.
Figure 11: Input Terminal Ripple Current, ic, at full rated output
current and nominal input voltage with 12µH source impedance
and 100µF electrolytic capacitor (200mA/div,2us/div).
DS_H48SA48003_09292012
5
ELECTRICAL CHARACTERISTICS CURVES
Figure 12: Input reflected ripple current, is, through a 12µH
source inductor at nominal input voltage and rated load current
(20mA/div,2us/div).
Figure 13: Output voltage noise and ripple measurement test
setup.
Figure 14: Output voltage ripple at nominal input voltage and
rated load current (Io=3.2A) (50mV/div,2us/div) Load
capacitance: 1µF ceramic capacitor and 470µF electrolytic
capacitor. Bandwidth: 20MHz. Scope measurements should be
made using a BNC cable (length shorter than 20 inches).
Position the load between 51 mm to 76 mm (2 inches to 3
inches) from the module.
Figure 15: Output voltage vs. load current showing typical
current limit curves and converter shutdown points.
DS_H48SA48003_09292012
6
DESIGN CONSIDERATIONS
Input Source Impedance
The impedance of the input source connecting to the
DC/DC power modules will interact with the modules
and affect the stability. A low ac-impedance input source
is recommended. If the source inductance is more than
a few µH, we advise adding a 10µF to 100µF electrolytic
capacitor (ESR < 0.7 Ω at 100 kHz) mounted close to
the input of the module to improve the stability.
Layout and EMC Considerations
Delta’s DC/DC power modules are designed to operate
in a wide variety of systems and applications. For design
assistance with EMC compliance and related PWB
layout issues, please contact Delta’s technical support
team. An external input filter module is available for
easier EMC compliance design. Application notes to
assist designers in addressing these issues are pending
release.
Safety Considerations
The power module must be installed in compliance with
the spacing and separation requirements of the
end-user’s safety agency standard, i.e., UL60950-1,
CSA C22.2 NO. 60950-1 2nd and IEC 60950-1 2nd :
2005 and EN 60950-1 2nd: 2006+A11+A1: 2010, if the
system in which the power module is to be used must
meet safety agency requirements.
When installed into a Class II equipment (without
grounding), spacing consideration should be given to
the end-use installation, as the spacing between the
module and mounting surface have not been
evaluated.
The power module has extra-low voltage (ELV) outputs
when all inputs are ELV.
This power module is not internally fused. To achieve
optimum safety and system protection, an input line
fuse is highly recommended. The safety agencies
require a Fast-acting fuse with 20A maximum rating to
be installed in the ungrounded lead. A lower rated fuse
can be used based on the maximum inrush transient
energy and maximum input current.
Soldering and Cleaning Considerations
Post solder cleaning is usually the final board assembly
process before the board or system undergoes
electrical testing. Inadequate cleaning and/or drying
may lower the reliability of a power module and
severely affect the finished circuit board assembly test.
Adequate cleaning and/or drying is especially important
for un-encapsulated and/or open frame type power
modules. For assistance on appropriate soldering and
cleaning procedures, please contact Delta’s technical
support team.
Basic insulation based on 75 Vdc input is provided
between the input and output of the module for the
purpose of applying insulation requirements when the
input to this DC-to-DC converter is identified as TNV-2
or SELV. An additional evaluation is needed if the
source is other than TNV-2 or SELV.
When the input source is SELV circuit, the power module
meets SELV (safety extra-low voltage) requirements. If
the input source is a hazardous voltage which is greater
than 60 Vdc and less than or equal to 75 Vdc, for the
module’s output to meet SELV requirements, all of the
following must be met:
Š
The input source must be insulated from the ac
mains by reinforced or double insulation.
Š
The input terminals of the module are not operator
accessible.
Š
A SELV reliability test is conducted on the system
where the module is used, in combination with the
module, to ensure that under a single fault,
hazardous voltage does not appear at the module’s
output.
DS_H48SA48003_09292012
7
FEATURES DESCRIPTIONS
Over-Current Protection
The modules include an internal output over-current
protection circuit, which will endure current limiting for
an unlimited duration during output overload. If the
output current exceeds the OCP set point, the modules
will automatically shut down (hiccup mode).
For negative logic, if the remote on/off feature is not
used, please short the on/off pin to Vi (-). For positive
logic, if the remote on/off feature is not used, please
leave the on/off pin to floating.
The modules will try to restart after shutdown. If the
overload condition still exists, the module will shut down
again. This restart trial will continue until the overload
condition is corrected.
Over-Voltage Protection
The modules include an internal output over-voltage
protection circuit, which monitors the voltage on the
output terminals. The default OVP operation is latch
mode. Under latch mode, If this voltage exceeds the
over-voltage set point, the module will shut down and
latch off. The over-voltage latch is reset by either cycling
the input power or by toggling the on/off signal for one
second.
Also, an optional hiccup mode for OVP is available.
under hiccup mode, the modules will try to restart after
shutdown. If the over voltage condition still exists, the
module will shut down again. This restart trial will
continue until the over-voltage condition is corrected.
Figure 16: Remote on/off implementation
Output Voltage Adjustment (TRIM)
To increase or decrease the output voltage set point,
the modules may be connected with an external
resistor between the TRIM pin and either Vout1 (+) or
Vout (-). The TRIM pin should be left open if this
feature is not used.
Over-Temperature Protection
The over-temperature protection consists of circuitry
that provides protection from thermal damage. If the
temperature exceeds the over-temperature threshold
the module will shut down.
The module will try to restart after shutdown. If the
over-temperature condition still exists during restart, the
module will shut down again. This restart trial will
continue until the temperature is within specification.
Remote On/Off
The remote on/off feature on the module can be either
negative or positive logic. Negative logic turns the
module on during a logic low and off during a logic high.
Positive logic turns the modules on during a logic high
and off during a logic low.
Remote on/off can be controlled by an external switch
between the on/off terminal and the Vi(-) terminal. The
switch can be an open collector or open drain.
DS_H48SA48003_09292012
Figure 17: Circuit configuration for trim-up (increase output
voltage)
If the external resistor is connected between the TRIM
and sense (+) pin, the output voltage set point increases
(Fig. 17). The external resistor value required to obtain
output voltage change to Vo is defined as:
Note:Vn is normal output voltage.
Ex.When Trim-up10%,Vo is (10%+1) *Vn =1.1*48 = 52.8V
Rtrim −up =
1 − ( 2.5 − 1.2 * 48) * (52.8 / 48)
= 616.1KΩ
(52.8 / 48) − 1
8
THERMAL CONSIDERATIONS
Thermal management is an important part of the system
design. To ensure proper, reliable operation, sufficient
cooling of the power module is needed over the entire
temperature range of the module. Convection cooling is
usually the dominant mode of heat transfer.
Figure 18: Circuit configuration for trim-down (decrease
output voltage)
If the external resistor is connected between the TRIM
and sense(-), Vout decreases (Fig. 18). The external
resistor value required to obtain output voltage change
to Vo is defined as:
Note:Vn is normal output voltage.
Ex. When Trim-down 10%,Vo is Vn-10%*Vn = 48-48*0.1
= 43.2V
Rtrim−down =
2.5 * ( 43.2 / 48) − 1
= 12.5( KΩ)
1 − ( 43.2 / 48)
Hence, the choice of equipment to characterize the
thermal performance of the power module is a wind
tunnel.
Thermal Testing Setup
Delta’s DC/DC power modules are characterized in
heated vertical wind tunnels that simulate the thermal
environments encountered in most electronics
equipment. This type of equipment commonly uses
vertically mounted circuit cards in cabinet racks in which
the power modules are mounted.
The following figure shows the wind tunnel
characterization setup. The power module is mounted
on a test PWB and is vertically positioned within the
wind tunnel. The space between the neighboring PWB
and the top of the power module is constantly kept at
6.35mm (0.25’’).
PWB
FACING PWB
When using trim-up, the output voltage of the module
is usually increased, which increases the power output
of the module with the same output current.
Care should be taken to ensure that the maximum
output power of the module remains at or below the
maximum rated power.
MODULE
AIR VELOCITY
AND AMBIENT
TEMPERATURE
MEASURED BELOW
THE MODULE
50.8 (2.0”)
AIR FLOW
12.7 (0.5”)
Note: Wind Tunnel Test Setup Figure Dimensions are in millimeters and (Inches)
Figure 19: Wind tunnel test setup
Thermal Derating
Heat can be removed by increasing airflow over the
module. To enhance system reliability, the power
module should always be operated below the maximum
operating temperature. If the temperature exceeds the
maximum module temperature, reliability of the unit may
be affected.
DS_H48SA48003_09292012
9
THERMAL CURVES
(WITHOUT HEAT SPREADER)
THERMAL CURVES
(WITH HEAT SPREADER)
Figure 20: Temperature measurement location *
The allowed maximum hot spot temperature is defined at 123℃
Output Current (A)
H48SA48003(Standard) Output Current vs. Ambient Temperature and Air Velocity
@Vin = 48V (Either Orientation)
3.2
Figure 22: Temperature measurement location *
The allowed maximum hot spot temperature is defined at 100℃
Output Current (A)
H48SA48003(Standard) Outp ut Current vs. Ambient Temperature a nd Air Velocity
@Vin = 48 V (Eith er Orientation;With H eatsprea der)
3.2
2.8
2.8
Natural
Convection
Natu ra l
Convectio n
2.4
2.4
100LFM
100LFM
2.0
200LFM
1.6
200L FM
2.0
300LFM
1.6
300LFM
400LFM
400LFM
1.2
1.2
0.8
0.8
0.4
0.4
0.0
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (℃)
0.0
25
30
35
40
45
50
55
60
65
70
75
80
85
Ambient Temperature (℃)
Figure 21: Output current vs. ambient temperature and air velocity Figure 23: Output current vs. ambient temperature and air velocity
@Vin=48V(Either Orientation, Without Heat spreader)
@Vin=48V(Either Orientation, With Heat spreader)
DS_H48SA48003_09292012
10
MECHANICAL DRAWING (WITH HEAT SPREADER)
DS_H48SA48003_09292012
11
MECHANICAL DRAWING (WITHOUT HEAT SPREADER)
Pin No.
1
2
3
4
5
6
7
8
9
Name
Function
+Vin
ON/OFF
Case
-Vin
-Vout
-Sense
Trim
+Sense
+Vout
Positive input voltage
Remote ON/OFF
Optional
Negative input voltage
Negative output voltage
Negative remote sense
Output voltage trim
Positive remote sense
Positive output voltage
Pin Specification:
Pins 1-4,6-8
Pins 5 & 9
1.00mm (0.040”) diameter
2.00mm (0.079”) diameter
All pins are copper with matte Tin plated.
DS_H48SA48003_09292012
12
PART NUMBERING SYSTEM
H
48
S
A
480
03
P
N
H
Form
Input
Number of
Product
Output
Output
ON/OFF
Pin
Option Code
Factor
Voltage
Outputs
Series
Voltage
Current
Logic
Length
S - Single
A - Advanced
480 - 48V
03 - 3.2A
H - Half
Brick
48 36~75V
P- Positive
N- Negative
N - 0.145”
R - 0.170’’
Space- RoHs 5/6
F- RoHS 6/6
(Lead Free)
A – standard function
H - with Heatspreader
MODEL LIST
MODEL NAME
H48SA48003PN H
INPUT
36V~75V
OUTPUT
5.5A
48V
EFF @ 100% LOAD
3.2A
92.0%
Default remote on/off logic is negative and pin length is 0.145’’.
* For modules with through-hole pins and the optional heat spreader, they are intended for wave soldering assembly onto
system boards; please do not subject such modules through reflow Temperature profile.
CONTACT: www.delta.com.tw/dcdc
USA:
Telephone:
East Coast: 978-656-3993
West Coast: 510-668-5100
Fax: (978) 656 3964
Email: [email protected]
Europe:
Phone: +41 31 998 53 11
Fax: +41 31 998 53 53
Email: [email protected]
Asia & the rest of world:
Telephone: +886 3 4526107
ext 6220~6224
Fax: +886 3 4513485
Email: [email protected]
WARRANTY
Delta offers a two (2) year limited warranty. Complete warranty information is listed on our web site or is available upon request
from Delta.
Information furnished by Delta is believed to be accurate and reliable. However, no responsibility is assumed by Delta for its
use, nor for any infringements of patents or other rights of third parties, which may result from its use. No license is granted by
implication or otherwise under any patent or patent rights of Delta. Delta reserves the right to revise these specifications at any
time, without notice.
DS_H48SA48003_09292012
13