FCI HERS101G

Mechanical Dimensions
Description
HERS101~108G
.055(1.40)
.062(1.60)
.098(2.50)
.114(2.90)
.157(4.00)
.181(4.60)
.006(.152)
.012(.305)
.078(2.00)
.096(2.44)
.002(.051)
.008(.203)
.030(0.76)
.060(1.52)
SMA
.188(4.80)
.208(5.28)
Dimensions in inches and (millimeters)
Features
n HIGH SURGE CAPABILITY
n HIGH CURRENT CAPABILITY
n LOW FORWARD VOLTAGE DROP
n MEETS UL SPECIFICATION 94V-0
Electrical Characteristics @ 25o C.
Maximum Ratings
Units
HERS101G~108G
01G 02G 03G 04G 05G 06G 07G 08G
Peak Repetitive Reverse Voltage...VRRM
50
100
200 300
400
600 800 1000
Volts
RMS Reverse Voltage...VR(rms)
35
70
140 210
280
420 560
Volts
DC Blocking Voltage...VDC
50
100
200 300
400
600 800 1000
700
Volts
Average Forward Rectified Current...IF(av)
TA = 55°C
............................................. 1.0 ...............................................
Amps
Non-Repetitive Peak Forward Surge Current...IFSM
@ Rated Current & Temp
............................................. 3 0 ...............................................
Amps
Forward Voltage @ 1.0A...VF
--------- 1.0 -------
Volts
DC Reverse Current...IR
@ Rated DC Blocking Voltage
TC = 25°C
TC =100°C
Typical Junction Capacitance...CJ (Note 1)
Typical Reverse Recovery Time...tRR (Note 2)
Operating & Storage Temperature Range...TJ, TSTRG
1.3
1.3
-------- 1.7 ---------
............................................. 5.0 ............................................... µAmps
............................................. 5 0 ............................................... µAmps
............................................. 5 0 ...............................................
------------------ 50 ---------------
75
75
75
......................................... -65 to 150 ..........................................
Note: 1. Measured at 1.0MHZ and applied reverse voltage of 4.0V DC
2.Reverse Recovery Test Conditions IF=0.5A, IR=1.0A, Irr=0.25A
pF
nS
°C
30
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD RECTIFIED
CURRENT, AMPERES
1.0
0.8
0.6
0.4
0.2
60 Hz Resistive or
Inductive load
0
Pulse Width 8.3ms
Single Half-Sire-Wave
(JEDEC Method)
25
20
15
10
5
0
0
50
100
150
1
AMBIENT TEMPERATURE, C
FIG.3 - TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
100
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
10
INSTANTANEOUS REVERSE CURRENT,
MICROAMPERES
1000
US1A-US1D
US1G
1.0
US1J-US1M
0.1
o
TJ=25 C
PULSE WIDTH=300uS
1% DUTY CYCLE
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
100
o
TJ=125 C
10
1
o
TJ=25 C
0.1
1.8
0
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
100
o
TJ = 25 C
f = 1.0 MHZ
Vsig = 50mVp-p
10
1
0.1
20
40
60
80
100
PERCENT OF RATED PEAK REVERSE VOLTAGE,%
FIG.5 - TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE, pF
IINSTANTANEOUS FORWARD CURRENT,
AMPERES
10
NUMBER OF CYCLES AT 60Hz
o
1.0
4.0
10
REVERSE VOLTAGE, VOLTS
100
HERS101~108G
FIG.2 - MAXIMUM NON-REPETITIVE
PEAK FORWARD SURGE CURRENT
FIG.1 - FORWARD CURRENT DERATING CURVE