ZOWIE 1N5393

1N5391 THRU 1N5399
SILICON RECTIFIER
Reverse Voltage - 50 to 1000 Volts
Forward Current - 1.5 Amperes
DO-204AC
FEATURES
1.0(25.4)
MIN.
*
*
*
*
High relliability
Low reverse leakage
Low forward voltage drop
High current capability
1.0(25.4)
MIN.
0.300(7.6)
0.230(5.8)
0.140(3.6)
0.104(2.6)
DIA.
MECHANICAL DATA
0.034(0.86)
Case : JEDEC DO-204AC molded plastic
Epoxy : UL 94V-O rate flame retardant
Lead : MIL-STD-202F method 208C guaranteed
Mounting Position : Any
Weight : 0.38 gram
0.028(0.71)
DIA.
*Dimensions in inches and (millimeters)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature
SYMBOLS 1N5391 1N5392 1N5393 1N5394 1N5395 1N5396 1N5397 1N5398 1N5399 UNITS
unless otherwise specified.
Maximum repetitive peak reverse voltage
VRRM
50
100
200
300
400
500
600
800
1000
Volts
Maximum RMS voltage
VRMS
35
70
140
210
280
350
420
560
700
Volts
VDC
50
100
200
300
400
500
600
800
1000
Volts
Maximum DC blocking voltage
Maximum average forward rectified current
I(AV)
1.5
Amps
IFSM
50
Amps
Maximum instantaneous forward voltage at 1.5 A
VF
1.4
Volts
Maximum full load reverse current, full cycle
o
average 0.375" (9.5mm) lead length at TL=75 C
IR(AV)
30
uA
o
at TL=70 C
Peak forward surge current 8.3ms single half sine-wave
superimposed on rated load (JEDEC Method)
Maximum DC reverse current
at rated DC blocking voltage
o
TA=25 C
IR
o
TA=100 C
Typical junction capacitance ( NOTE )
Typical thermal resistance
Operating junction and storage temperature range
CJ
R
JA
TJ,TSTG
5.0
uA
50
20
50
-65 to +175
pF
o
C/W
o
C
NOTES : Measured at 1.0 MHz and applied reverse voltage of 4.0 Volts
REV. : 0
Zowie Technology Corporation
RATINGS AND CHARACTERISTIC CURVES 1N5391 THRU 1N5399
FIG.1 - FORWARD CURRENT DERATING CURVE
FIG.2 - MAXIMUM NON-REPETITIVE
PEAK FORWARD SURGE CURRENT
50
PEAK FORWARD SURGE CURRENT,
AMPERES
AVERAGE FORWARD RECTIFIED
CURRENT, AMPERES
1.50
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
1.25
1.00
0.75
0.50
0.25
8.3ms SINGLE HALF SINE-WAVE
(JEDEC Method)
40
30
20
10
0
0
0
25
50
75
100
125
150
1
175
10
FIG.3 - TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
FIG.4 - TYPICAL REVERSE CHARACTERISTICS
10
INSTANTANEOUS REVERSE LEAKAGE
CURRENT, MICROAMPERES
10.00
IINSTANTANEOUS FORWARD CURRENT,
AMPERES
100
NUMBER OF CYCLES AT 60Hz
o
AMBIENT TEMPERATURE, C
PULSE WIDTH=300uS
1% DUTY CYCLE
1.00
0.10
1.0
0.1
o
TJ=25 C
o
TJ=100 C
0.01
0
0.01
0.4
0.6
0.8
1.0
1.2
1.4
1.6
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE,%
INSTANTANEOUS FORWARD VOLTAGE,
VOLTS
FIG.5 - TYPICAL JUNCTION CAPACITANCE
JUNCTION CAPACITANCE, pF
200
o
TJ = 25 C
100
60
40
20
10
6
4
2
1
.1
.2
.4
1.0
2
4
10
20
40
100
REVERSE VOLTAGE, VOLTS
REV. : 0
Zowie Technology Corporation