ETC RXM4LB2JD

Electromechanical Zelio Relay
Presentation
RXM Optimum miniature plug-in relays
Presentation of the range
1
2
The RXM Optimum miniature relay range comprises:
1 5 A relay with 2 C/O contacts or 3 A relays with 4 C/O contacts.
The relays have the same dimensions.
2 Socket with mixed contact terminals.
3 Metal maintaining clamps (accessories).
2
1
3
3
4
Relay description
1
2
1
2
3
4
5
Area by which the product can be easily gripped.
Mechanical “relay status” indicator.
LED (depending on version) indicating the relay status.
Four notches for rail mounting adapter or panel mounting adapter with fixing lugs.
Eight or fourteen Faston type pins.
5
3
4
5
6
Socket description
1
7
2
8
1
2
3
4
5
Two fixing holes for panel mounting.
Connection by screw clamp terminals.
Eight or fourteen female contacts for the relay pins.
Two fixing holes for metal maintaining clamp.
Locating slot for mounting on DIN rail with fixing clip.
3
4
9
5
10
Presentation :
page 28212/2
2
Characteristics :
page 28212/3
References :
page 28212/5
Dimensions, schemes :
page 28212/6
28212-EN
version: 1.1
Electromechanical Zelio Relay
Characteristics
RXM Optimum miniature plug-in relays
General characteristics
Conforming to standards
e, ROHS, IEC/EN 61810-1 (iss.2)
Product certifications
None
Ambient air temperature
around the device
Storage
°C
- 40… + 85
Operation
°C
- 40… + 55
Vibration resistance
conforming to
IEC/EN60068-2-6
Operating
3 gn (10...50 Hz)
Not operating
6 gn (10...50 Hz)
Degree of protection conforming to IEC/EN 60529
IP 40
Shock resistance
conforming to
IEC/EN 60068-2-27
Opening
10 gn
Closing
5 gn
Protection category
RT I
Mounting position
Any
1
2
Insulation characteristics
Rated insulation voltage (Ui)
V
250 (IEC)
Rated impulse withstand voltage (Uimp)
kV
3.6 (1.2/50 μs)
Dielectric strength
(rms voltage)
Between coil and contact
aV
2000
Between poles
aV
2000
Between contacts
aV
1000
3
Contact characteristics
RXM 2LBppp
RXM 4LBppp
Number and type of contacts
Relay type
2 C/O
4 C/O
Contact materials
Silver Alloy
Silver Alloy
Conventional thermal current For ambient temperature y55 °C A
(Ith)
5
3
Rated operational current
Conforming to IEC
in utilisation categories AC-1 and
DC-1
N/O
5
3
N/C
2.5
1.5
Minimum switchable current
Switching voltage
Maximum
Minimum
Maximum
c/a 250
17
5 / 250 VAC
A
5 / 28 VDC
3 / 28 VDC
a
VA
1250
750
c
W
140
84
mW
170
170
3 / 250 VAC
No-load
18 000
Under load
1200
Mechanical durability
In millions of operating cycles
10
Electrical durability
In millions of operating cycles
Resistive load
0.1
Inductive load
See curves below
Utilisation coefficient
Durability (Number of operating cycles)
10
5
A
0
B
0,1 0,5
1 1,5 3
5
8
Contact current (A)
10
10
10
7
6
A
B
For 4 poles relay
8,0
Contact current (A)
Durability (Number of operating cycles)
7
For 2 poles relay
Contact current (A)
For 4 poles relay
6
7
Maximum switching capacity
For 2 poles relay
10
6
20 %
Electrical durability of contacts
10
5
V
Minimum
Maximum operating rate
In operating cycles/hour
10
A
Rated load (resistive)
Switching capacity
mA
V
4
B
5,0
A
3,0
1,0
D
C
8,0
5,0
3,0
A
1,0
0,5
0,5
0,1
0,1
C
8
B
D
5
0
0,1
0,5
1 1,5 3
5
8
Contact current (A)
A Inductive load
B Resistive load
0 5 10
50
100
200
500
Contact voltage (V)
0 5 10
50
100
200
500
Contact voltage (V)
A Inductive load a
B Resistive load a
C Inductive load c
D Resistive load c
10
Durability (inductive load) = durability (resistive load) x reduction coefficient.
28212-EN
version: 1.1
9
3
Electromechanical Zelio Relay
Characteristics (continued)
RXM Optimum miniature plug-in relays
Coil characteristics
1
Average consumption
Drop-out voltage threshold
Operating time
(response time)
2
a
VA
1.2
c
W
0,9
a
≥ 0.15 Uc
c
≥ 0.1 Uc
Between coil energisation
a
and making of the On-delay c
contact
ms
20
ms
20
Between coil de-energisation a
and making of the Off-delay c
contact
ms
20
ms
20
Control circuit voltage Uc
V
Relay control voltage codes
DC supply
3
4
36
48
110
120
CD
ED
FD
–
230
–
–
–
Ω
160
630
1500
2600
11000
Operating voltage limits
Min.
V
9.6
19.2
28.8
38.4
88
–
–
Max.
V
13.2
26.4
39.6
52.8
121
–
–
–
B7
–
–
–
F7
P7
Average resistance at 20 °C ± 15%
Ω
–
160
–
–
–
4500
15000
Operating voltage limits
Min.
V
–
19.2
–
–
–
96
184
Max.
V
–
26.4
–
–
–
132
253
Socket characteristics
Socket Type
RXZ E1M2C
RXZ E1M4C
Relay Type
RXM 2ppppp
RXM 2ppppp, RXM 4ppppp
Contact terminal arrangement
Mixed
Wire connection method
Screw clamp
Width
5
24
BD
Average resistance at 20 °C ± 10%
Relay control voltage codes
AC supply
12
JD
mm
22.5
Product certifications
None
Conformity to standards
e, ROHS, IEC 61984
29
Electrical Ratings
Conventional Thermal Current (Ith)
A
7
Nominal Voltage Rating
V
250 (IEC)
Dielectric Strength
6
Output to Adjacent Output Terminals
Vrms 2 500
Output to Input Terminals
Vrms 2 500
General Characteristics
Temperature range
Operating
°C
Storage
°C
Degree of protection
Conforming to IEC/EN 60529
Connection
Solid cable without 1 conductor
cable end
7
2 conductors
- 40…+ 55
- 55…+ 85
IP 20
mm2
0.5…1.5
AWG 20…16
mm2
0.5…1.5
AWG 20…16
Flexible cable with 1 conductor
cable end
2 conductors
8
9
mm2
0.25…1
AWG 22…17
mm2
0.25…1
AWG 22…17
Screw Size
mm
M3
Maximum tightening torque
Nm
0.8 (M3 Screw)
Mounting
35 mm DIN Rail / Panel
DIN Rail locking method
Red Plastic Clip
Terminal Marking
IEC, NEMA
Relay fixing plastic clip compatible
No
Relay fixing metal clip compatible
Yes
Yes
Protection modules
No
No
Clip-In legend
No
No
No
10
4
28212-EN
version: 1.1
References
Electromechanical Zelio Relay
RXM Optimum miniature plug-in relays
References
Miniature relays without lockable test-button, with LED
1
(sold in lots of 10)
Control
circuit
voltage
Number and type of contacts - Thermal current (Ith)
2 C/O - 5 A
Unit
reference
4 C/O - 3 A
Weight
V
c 12
RXM pLBppp
Unit
reference
Weight
kg
RXM 2LB2JD
0.033
kg
RXM 4LB2JD
0.035
c 24
RXM 2LB2BD
0.032
RXM 4LB2BD
0.034
c 36
RXM 2LB2CD
0.034
RXM 4LB2CD
0.036
c 48
RXM 2LB2ED
0.033
RXM 4LB2ED
0.035
c 110
RXM 2LB2FD
0.031
RXM 4LB2FD
0.033
a 24
RXM 2LB2B7
0.033
RXM 4LB2B7
0.035
a 120
RXM 2LB2F7
0.032
RXM 4LB2F7
0.033
a 230
RXM 2LB2P7
0.031
RXM 4LB2P7
0.032
Miniature relays without lockable test-button, without LED
2
3
(sold in lots of 10)
Control
circuit
voltage
Number and type of contacts - Thermal current (Ith)
2 C/O - 5 A
Unit
reference
4 C/O - 3 A
Weight
V
c 12
RXZ E1MpC
Unit
reference
kg
RXM 2LB1JD
0.032
Weight
kg
RXM 4LB1JD
4
0.034
c 24
RXM 2LB1BD
0.032
RXM 4LB1BD
0.033
c 48
RXM 2LB1ED
0.033
RXM 4LB1ED
0.034
a 24
RXM 2LB1B7
0.033
RXM 4LB1B7
0.034
a 120
RXM 2LB1F7
0.031
RXM 4LB1F7
0.033
a 230
RXM 2LB1P7
0.030
RXM 4LB1P7
0.032
Sockets
5
(sold in lots of 10)
Contact terminal
arrangement
Mixed
Connection
Relay
type
Unit
reference
Weight
kg
Screw clamp
RXM2
RXZ E1M2C
0.034
Screw clamp
RXM2
RXM4
RXZ E1M4C
0.053
Accessories
6
(sold in lots of 10)
Description
Metal maintaining clamp
For use with
Unit
reference
Weight
kg
RXZ E1M2C
RXZ 420
0.001
RXZ E1M4C
RXZ 430
0.001
nota: If protection module needed, please used the RZE2p sockets with the associated
protection module RXM0. You can find all the details in the RXMpAB range.
7
RXZ 420
8
RXZ 430
9
10
28212-EN
version: 1.1
5
Electromechanical Zelio Relay
Dimensions
RXM Optimum miniature plug-in relays
Dimensions
Miniature relays
RXM pppppppppp
RXM 2ppppp
Common view
RXM 4ppppp
Pin side view
2
4,5 4,5 4,5
27
6,5 6 4 4
1
21
40
6
2,5
21
4,5
2,5
2,5
13,5
2,5
13,5
Sockets
RXZ E1M2C
RXZ E1M4C
2-42 x 5
4
8
2-42 x 5
5
9
14
13
15 ± 0,1
5
30 ± 0,2
22 ± 0,1
3
2
1
7
6
5
59 ± 0,1
8
59 ± 0,1
75 ± 0,2
4
1
75 ± 0,2
3
30 ± 0,2
12
11 10 9
4
14 13
22 ± 0,1
29 ± 0,1
6
7
8
9
10
6
28212-EN
version: 1.1
Electromechanical Zelio Relay
Schemes
RXM Optimum miniature plug-in relays
Schemes
Miniature relays
1
A2
41
A1
44
34
32
42
31
22
24
21
14
12
A2
A1
11
44
RXM 4ppppp
41
42
14
11
12
RXM 2ppppp
1
4
1
2
3
4
12
5
42
8
12
5
22
6
32
7
42
8
14
9
44
12
14
9
24
10
34
11
44
12
11
13
41
14
11
13
21
31
41
14
A1
A2
A1
2
3
A2
Symbols shown in blue correspond to Nema marking.
4
5
6
7
8
9
10
28212-EN
version: 1.1
7