ETC G6D-1A

Power PCB Relay
G6D
Reduced board space ideal for highdensity mounting (45% smaller than
the surface area of G6B)
■ Slim package: measures 6.5 W x 17.5 L
x 12.5 H mm (0.26 x 0.69 x 0.49 in)
■ Switches loads up to 5 A, 250 VAC/
30 VDC
■
Fully sealed construction allows
automatic soldering and cleaning
■ Long service life: up to 300,000 operations with a 2 A, 250 VAC/30 VDC load
■
Rated for D150 pilot duty by UL, CSA
■ Optional mounting socket simplifies
relay installation and servicing of
finished equipment
■
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6D-1A-DC12).
Type
Standard
Contact form
SPST-NO
Terminal
PCB
Construction
Fully sealed
Part number
G6D-1A
■ ACCESSORIES
Connecting Socket
Description
PCB mount socket for G6D relay
Part number
P6D-04P
Specifications
■ CONTACT DATA
Load
Rated load
Contact material
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
Resistive load (p.f. = 1)
5 A at 250 VAC, 30 VDC
Ag alloy
5A
250 VAC, 30 VDC
5A
1,250 VA, 150 W
10 mA at 5 VDC
Inductive load (p.f. = 0.40, L/R = 7 ms)
2 A at 250 VAC, 30 VDC
500 VA, 60 W
G6D
G6D
■ COIL DATA
Rated
voltage
(VDC)
Rated
current
(mA)
Coil
resistance
(Ω)
Pick-up
voltage
5
12
24
40
16.7
8.3
125
720
2,880
70% max.
Dropout
voltage
Maximum
voltage
Power
consumption
(mW)
10% min.
130%
at 70°C (158°F)
Approx. 200
% of rated voltage
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.
2. Operating characteristics are measured at a coil temperature of 23°C (73°F).
3. The pick-up voltage is 75% or less of rated voltage if the relay is mounted upside down.
■ CHARACTERISTICS
Contact resistance
Operate time
Release time
Bounce time
Operating
frequency
Insulation resistance
Dielectric strength
Operate
Mechanical
Electrical
Surge withstand voltage
Vibration
Mechanical durability
Malfunction durability
Shock
Mechanical durability
Malfunction durability
Ambient temperature
Operating
Humidity
Life expectancy
Mechanical
Electrical
Weight
100 mΩ max.
10 ms max. (mean value: approx. 4.30 ms)
10 ms max. (mean value: approx. 5.50 ms)
Mean value: approx. 1.20 ms
18,000 operations/hour
1,800 operations/hour (under rated load)
1,000 MΩ min. (at 500 VDC)
3,000 VAC, 50/60 Hz for 1 minute between coil and contacts
750 VAC, 50/60 Hz for 1 minute between contacts of the same polarity
6,000 V, 1.20 x 50 µs between coil and contacts
10 to 55 Hz, 1.50 mm (0.06 in) double amplitude for 2 hours
10 to 55 Hz, 1.50 mm (0.06 in) double amplitude for 5 minutes
1,000 m/s2 (approx. 100 G)
100 m/s2 (approx. 10 G)
-25° to 70°C (-13° to 158°F)
45% to 85% RH
20 million operations min. (at operating frequency of 18,000 operations/hour)
See “Characteristic Data”
Approx. 3 g (0.10 oz)
Note: Data shown are of initial value.
■ CHARACTERISTIC DATA
Ambient temperature vs.
maximum voltage
Maximum voltage (%)
Switching current (A)
Switching voltage (V)
2
Life expectancy
Life expectancy (x103 operations)
Maximum switching capacity
Switching current (A)
Ambient temperature (°C)
G6D
G6D
Dimensions
Unit: mm (inch)
■ RELAYS
G6D-1A
Terminal arrangement/
Internal connections
(Bottom view)
Mounting holes
(Bottom view)
Tolerance: ± 0.1 (0.04)
■ SOCKET
P6D-04P
Mounting holes
(Bottom view)
Tolerance: ± 0.1 (0.04)
3
G6D
G6D
■ APPROVALS
UL (File No. E41515)/CSA (File No. LR31928)
Type
G6D-1A
Contact form
SPST-NO
Coil ratings
5 to 24 VDC
Contact ratings
5 A, 250 VAC (Resistive)
5 A, 30 VDC (Resistive)
1/10 HP, 120 VAC
D150 Pilot Duty
Note: 1. The rated values approved by each of the safety standards (e.g., UL, CSA, TUV) may be different from the performance
characteristics individually defined in this catalog.
2. In the interest of product improvement, specifications are subject to change.
Precautions
■ SPACING BETWEEN RELAYS
■ SOCKET MOUNTING
More than two relays can be closely mounted right side up as
shown in the illustration below.
When mounting the relay, insert it into the socket as vertically
as possible so that the relay terminals contact securely with the
contact pins on the socket.
The P6D-04P socket is flux-resistant. Do not wash the socket
with water.
Remove the relay from the socket before soldering the socket to
a PC board.
Mounting height
More than two relays can be closely mounted upside down as
shown in the illustration below.
Note: The space between each relay required for heat radiation
may vary with operating conditions.
NOTE: DIMENSIONS ARE SHOWN IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
Schaumburg, IL 60173
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. GC RLY7
4
01/00
Specifications subject to change without notice.
Printed in the U.S.A.