NI NIPXI

850 MHz Intel Celeron Real-Time
Embedded Controllers for PXI
NI PXI-8183 RT NEW!
• 2-slot real-time controller
• Intel Celeron processor
(850 MHz single core)
• 256 MB (1 x 256 MB DIMM)
RAM (standard)
• Execution target for NI LabVIEW
Real-Time or LabWindows™/CVI
Real-Time applications
• Reliable and deterministic operation
• Ethernet control of PXI
• Watchdog timer
• 21 kHz single PID loop rate, maximum
Development System
Requirements (Windows)
• LabVIEW
• LabVIEW Real-Time Module
Or
• LabWindows/CVI
• LabWindows/CVI Real-Time Module
Deployment Software (included)
• LabVIEW Real-Time embedded software
PXI System Configuration
• Complete PXI system configuration at
ni.com/pxiadvisor
Overview
National Instruments RT Series PXI embedded controllers deliver a
flexible, rugged platform for your deterministic, real-time measurement
and control applications. This 2-slot embedded controller features an
850 MHz Intel Celeron processor and offers an ideal low-cost platform
for deploying PXI-based systems in real-time applications. You develop
your LabVIEW application with the NI LabVIEW Real-Time Module on
Windows and download the program to your PXI-8183 RT controller via
Ethernet. The embedded code executes on a real-time OS; thus, you can
use the powerful and flexible development tools of LabVIEW to build
reliable, real-time solutions.
LabVIEW Real-Time applications running on PXI systems achieve
microsecond loop rates with only 3 to 4 ns of system jitter. These
real-time measurement and control systems capitalize on the latest
processors combined with the advanced timing, triggering, and I/O
synchronization benefits of PXI. Furthermore, NI measurement services
software extends the timing capabilities of PXI to deliver tight
integration with LabVIEW Real-Time applications through operations
such as hardware-timed software loops.
Built-in LabVIEW libraries help you create applications with data
acquisition, dynamic signal acquisition, motion control, image
acquisition, reconfigurable I/O, and instrumentation. Communicate
with peripheral devices through CAN, GPIB, Ethernet, or serial protocols.
Use NI-VISA to integrate third-party PXI/CompactPCI modules in
your application.
In addition, the PXI-8183 RT controller includes an external SMB
connection for use as a trigger input, output, or watchdog timer. Use the
external SMB to pass trigger and timing signals into and out of the PXI
trigger bus in your system.
CPU
Intel Celeron Processor
(850 MHz Single Core)
RAM, standard
RAM, maximum
Storage, hard drive (minimum)
Storage, solid state
Extended temperature and 24/7 operation option
10/100BASE-TX Fast Ethernet
Serial port (RS232)
Parallel port
USB ports (v1.1)
Watchdog/trigger SMB
256 MB (1 x 256 MB)
512 MB (1 x 512 MB)
40 GB PATA
Optional1
–
✔
✔
✔
2
✔
1 Optional
Connect to Any I/O
The modularity of PXI and open development environment of LabVIEW
make it easy to integrate a variety of I/O within your application. Create
a custom real-time embedded solution using a PXI-8183 RT embedded
controller with any number and combination of PXI/CompactPCI
plug-in modules.
512 or 128 MB solid-state drive can replace the hard drive.
Table 1. PXI-8183 RT Features
850 MHz Intel Celeron Real-Time Embedded Controllers for PXI
Create Reliable Stand-Alone Systems
To ensure reliable operation, embedded LabVIEW Real-Time applications
continue to run even if the host PC is interrupted or rebooted. Because
the PXI-8183 RT embedded controller runs in a separate chassis with a
dedicated power supply, the operator can shut down the host computer
entirely without disrupting the real-time program.
For stand-alone operation, you can embed code in the system so
that it starts automatically when the system boots, requiring no human
interaction. Use the LabVIEW Professional Development System and
LabVIEW Real-Time Module to compile your LabVIEW application into
an executable and download it to your PXI-8183 RT controller.
Benchmark
Processing
Analog input and output
Analog input and output
Analog input and output
Analog input and output
PID
PID
PID
PID
Channels DAQ I/O Mode
1
1
16
16
Polling
Interrupts
Polling
Interrupts
Loop Rates (kHz)
PXI-8183 RT
21.7
9.7
5.5
3.4
Table 2. Maximum loop rates for LabVIEW Real-Time PXI systems are shown. All
benchmarks use the LabVIEW 8.5 Real-Time Module with NI-DAQmx 8.7. These
benchmarks do not test network performance and run on a headless target without a
direct Ethernet connection for maximum performance. Visit ni.com or contact
National Instruments for additional benchmarks.
Dual-Boot Option
You can configure NI PXI embedded controllers to boot into Windows
or the real-time OS. NI Measurement & Automation Explorer (MAX)
includes features for installing and configuring PXI embedded controllers
as LabVIEW Real-Time targets. The controllers use a hardware switch or
BIOS setting to boot into the desired OS.
The result is a PXI embedded controller that can run embedded
LabVIEW Real-Time or Windows applications. When the controller is
in real-time mode, you need another Windows computer to develop and
debug the LabVIEW Real-Time code for the PXI controller. To enable a
Windows PXI embedded controller to dual-boot with the real-time OS,
you must purchase the LabVIEW Real-Time embedded deployment
software for the controller.
Ordering Information
To order a complete PXI system based on a LabVIEW Real-Time
embedded controller, visit ni.com/pxiadvisor.
Controller
NI PXI-8183 RT ......................................................................780343-33
Memory Upgrades
Standard
256 MB (1 x 256 MB DIMM)
Recommended upgraded memory configurations:
512 MB (1 x 512 MB DIMM must be purchased)
512 MB SDRAM ..................................................................778469-512
Solid-State Storage Options
128 MB solid-state HDD ....................................................779175-128
512 MB solid-state HDD ....................................................779175-512
Accessories
Parallel port adapter cable (6 in.)..........................................777169-01
NI MKD-1117 (rack-mount 1U LCD monitor,
keyboard, mouse drawer) .................................................779872-01
NI PXI-8232, combo gigabit Ethernet and GPIB, NI-488.2....778658-01
NI PXI-8252 IEEE 1394 interface module..............................778925-01
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/pxi.
BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.)
2
850 MHz Intel Celeron Real-Time Embedded Controllers for PXI
Specifications subject to change without notice.
Features
Processor............................................. 850 MHz Intel Celeron
System memory (RAM) ....................... 256 MB, 7.5 ns SDRAM (standard)
512 MB, 7.5 ns SDRAM (maximum)
Ethernet............................................... 10/100BASE-TX, RJ45 connector
Hard drive............................................ 40 GB minimum, internal 2.5 in.,
9.5 mm Fast Ultra
ATA100 Interface
Serial ................................................... 1 (RS232)
Parallel ................................................ IEEE 1284, Type C Connector
USB .................................................... 2 x USB 1.1
Power Requirements
Current
Voltage (V)
+3.3
+5
+12
-12
Typical
3.0
4.5
0.01
0.0
Maximum
4.0
6.0
0.04
0.0
Random vibration
Operating ........................................ 5 to 500 Hz, 0.3 grms
(with solid-state hard drive)
Nonoperating.................................. 5 to 500 Hz, 2.4 grms
(tested in accordance with
IEC-60068-2-64; nonoperating
test profile exceeds the
requirements of MIL-PRF-28800F,
Class 3)
Safety and Compliance
Safety
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA 61010-1
Note: For UL and other safety certifications, refer to the product label or
visit ni.com/certification, search by model number or product line, and
click the appropriate link in the Certification column.
Physical
Electromagnetic Compatibility
Board dimensions ............................... 2-slot 3U PXI Express module
Slot requirements ............................... 1 system slot plus 1 controller
expansion slot (to the left of the
system slot)
Compatibility ....................................... Fully compatible with
PXI specification
Weight................................................. 0.82 kg (1.8 lb) typical
This product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control,
and laboratory use:
• EN 61326 EMC requirements; Minimum Immunity
• EN 55011 Emissions; Group 1, Class A
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Operating Environment
Note: For EMC compliance, operate this device according to
product documentation.
Ambient temperature range1 .............. 5 to 50 °C2, 3 (tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2)
Relative humidity range...................... 10 to 90%, noncondensing
(tested in accordance with
IEC-60068-2-56)
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
1 For
chassis not available in the online catalog at ni.com, please contact National
Instruments for supported operating temperatures.
25
to 50 °C for NI PXI-1036 Revision D and later, and NI PXI-1036DC Revision C and later.
35
to 40 °C for NI PXI-1036 revisions B and C and NI PXI-1036DC Revision B.
Storage Environment
Ambient temperature range ............... -40 to 65 °C (tested in
accordance with IEC-60068-2-1
and IEC-60068-2-2)
Relative humidity range...................... 5 to 95% noncondensing
(tested in accordance with
IEC-60068-2-56)
CE Compliance
• 2006/95/EC; Low-Voltage Directive (safety)
• 2004/108/EC; Electromagnetic Compatibility Directive (EMC)
Note: Refer to the Declaration of Conformity (DoC) for this product for
any additional regulatory compliance information. To obtain the DoC for
this product, visit ni.com/certification, search by model number or
product line, and click the appropriate link in the Certification column.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers: At the end of their life cycle, all products must be
sent to a WEEE recycling center. For more information about WEEE
recycling centers and National Instruments WEEE initiatives,
visit ni.com/environment/weee.htm.
Shock and Vibration
Operating shock .................................. 30 g peak, half-sine, 11 ms pulse
(tested in accordance with
IEC-60068-2-27; test profile
developed in accordance
with MIL-PRF-28800F)
BUY ONLINE a t ni.com o r CALL 800 813 3693 (U.S.)
3
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional Services
Our NI Professional Services team is composed of NI applications
and systems engineers and a worldwide National I n s t ruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range
from start-up assistance to
turnkey system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
ni.com • 800 813 3693
National Instruments • [email protected]
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
*351592A-01*
351592A-01
2008-9477-501-101-D
©2008 National Instruments Corporation. All rights reserved. CVI, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks of
National Instruments. The mark LabWindows is used under a license from Microsoft Corporation. Windows is a registered trademark of Microsoft Corporation in the United States and
other countries. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity
independent from NI and has no agency, partnership, or joint-venture relationship with NI.