CompactRIO High-Performance Real-Time Controllers NI cRIO-9012, NI cRIO-9014 NEW! • Small and rugged embedded real-time controllers • Execution target for NI LabVIEW Real-Time applications • Reliable and deterministic operation for stand-alone control, monitoring, and logging • 400 MHz Freescale MPC5200 real-time processor • -40 to 70 °C operating temperature range Product cRIO-9012 cRIO-9014 Operating System • LabVIEW Real-Time (VxWorks) Driver Software • NI-RIO for reconfigurable embedded systems DRAM Memory (MB) Internal Nonvolatile Storage (MB) 10/100BaseT/TX Ethernet Port RS232 Serial Port USB Port 64 128 128 2000 LEDs DIP Switches Power Supply Input Range Power Consumption Backup Power Input Remote Panel Web Server FTP Server 4 4 5 5 9 to 35 VDC 9 to 35 VDC 6 W max 6 W max Overview and Applications Embedded Software The National Instruments cRIO-901x controllers feature an industrial 400 MHz Freescale MPC5200 real-time processor for deterministic and reliable real-time applications. Both embedded controllers are designed for extreme ruggedness, reliability, and low power consumption with dual 9 to 35 VDC supply inputs that deliver isolated power to the CompactRIO chassis/modules and a -40 to 70 °C operating temperature range. The cRIO-901x controllers accept 9 to 35 VDC power supply inputs on power-up and 6 to 35 VDC power supply inputs during operation, so they can function for long periods of time in remote applications using a battery or solar power. With the 10/100 Mb/s Ethernet and serial ports, you can communicate via TCP/IP, UDP, Modbus/TCP, and serial protocols. The cRIO-901x controllers also feature built-in Web (HTTP) and file (FTP) servers. For additional storage capability, cRIO-901x controllers have a full-speed USB host port to which you can connect external USB-based storage media (flash drives and hard drives) for embedded logging applications requiring additional storage. Also, there is a fault-tolerant file system embedded in cRIO-901x controllers that provides increased reliability for data logging. CompactRIO real-time controllers connect to any 4 or 8-slot cRIO-910x reconfigurable chassis. The embedded FPGA in the chassis controls each I/O module and passes data to the controller through a local PCI bus using built-in communications functions. The cRIO-901x controllers run the National Instruments LabVIEW Real-Time Module on the Wind River VxWorks real-time operating system (RTOS) for extreme reliability and determinism. You can now use the leading VxWorks RTOS technology to quickly design, prototype, and deploy a customizable COTS embedded system using NI LabVIEW graphical programming tools. Ordering Information NI cRIO-9012 ........................................................................779563-01 NI cRIO-9014 ........................................................................ 779564-01 Accessories NI 9978 (4-pos screw-terminal power supply plugs, quantity 5)..........................................................................196938-01 NI 9979 (strain relief kit for 4-pos power connector) ..........196939-01 BUY NOW! For complete product specifications, pricing, and accessory information, call 800 813 3693 (U.S.) or go to ni.com/compactrio. CompactRIO High-Performance Real-Time Controllers Power Requirements Specifications Caution: You must use a National Electric Code (NEC) UL Listed Class 2 power supply with cRIO-901x controllers. Minimum Software Support Information CompactRIO Real-Time Controller Minimum Version of LabVIEW Real-Time Module Minimum Version of NI-RIO Driver 8.2 8.2.1 2.1 2.1.3 cRIO-9012 cRIO-9014 Specifications subject to change without notice. The following specifications are typical for the range -40 to 70 °C unless otherwise noted. Network Network interface ................................... 10BaseT and 100BaseTX Ethernet Compatibility ....................................... IEEE 802.3 Communication rates.......................... 10 Mb/s, 100 Mb/s, autonegotiated Maximum cabling distance................. 100 m/segment SMB Connector Output Characteristics Logic high............................................ Logic low............................................. Driver type........................................... Sink/source current............................. 3-state output leakage current ........... 3.3 V 0V CMOS ±50 mA ±5 µA 20 W 9 to 35 V 6 to 35 V Note: The cRIO-901x controllers are guaranteed to power up when 9 V is applied to V and C. After power-up, it can operate on as little as 6 V. Physical Characteristics If you need to clean the controller, wipe it with a dry towel. Screw-terminal wiring ........................ 12 to 24 AWG copper conductor wire with 10 mm (0.39 in.) of insulation stripped from the end Torque for screw terminals.................... 0.5 to 0.6 N · m (4.4 to 5.3 lb · in.) Weight................................................. Approx. 488 g (17.2 oz) Measurement Category I is for measurements performed on circuits not directly connected to the electrical distribution system referred to as MAINS voltage. MAINS is a hazardous live electrical supply system that powers equipment. This category is for measurements of voltages from specially protected secondary circuits. Such voltage measurements include signal levels, special equipment, limited-energy parts of equipment, circuits powered by regulated low-voltage sources, and electronics. -500 mV 990 mV 2.31 V 5.5 V 2.5 pF 1 kΩ to 3.3 V Caution: Do not connect to signals or use for measurements within measurement categories II, III, or IV. Maximum data rate ............................ 12 Mb/s Maximum current................................ 500 mA cRIO-9012 cRIO-9014 6W Connect only voltages that are within these limits. V-to-C .................................................. 35 V max, Measurement Category I USB Port CompactRIO Real-Time Controller 48 W secondary, 18 to 24 VDC Safety Voltages Input Characteristics Minimum input level........................... Maximum input low level ................... Minimum input high level................... Maximum input level .......................... Input capacitance................................ Resistive strapping ............................. Recommended power supply.............. Power consumption Controller only ................................ Controller supplying power to eight CompactRIO modules........ Power supply On power-up ................................... After power-up ............................... Safety Standards Nonvolatile Storage DRAM 128 MB 2 GB 64 MB 128 MB Memory Use the following formula to determine the minimum life span in years of the nonvolatile storage of your cRIO-901x controller: Minimum life span in years = [Amount of memory in controller (MB) x 100,000 / 365 days] / [file size (MB) x write rate (per day)] This product is designed to meet the requirements of the following standards of safety for electrical equipment for measurement, control, and laboratory use: • IEC 61010-1, EN 61010-1 • UL 61010-1, CSA 61010-1 Note: For UL and other safety certifications, refer to the product label or visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) 2 CompactRIO High-Performance Real-Time Controllers Electromagnetic Compatibility Environmental This product is designed to meet the requirements of the following standards of EMC for electrical equipment for measurement, control, and laboratory use: The cRIO-901x controllers are intended for indoor use only. For outdoor use, mount the CompactRIO system in a suitably rated enclosure. • EN 61326 EMC requirements; Industrial Immunity • EN 55011 Emissions; Group 1, Class A • CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A Note: For EMC compliance, operate this device according to product documentation. CE Compliance This product meets the essential requirements of applicable European Directives, as amended for CE marking, as follows: • 73/23/EEC; Low-Voltage Directive (safety) • 89/336/EEC; Electromagnetic Compatibility Directive (EMC) Note: Refer to the Declaration of Conformity (DoC) for this product for any additional regulatory compliance information. To obtain the DoC for this product, visit ni.com/certification, search by model number or product line, and click the appropriate link in the Certification column. Waste Electrical and Electronic Equipment (WEEE) EU Customers: At the end of their life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee.htm. Hazardous Locations U.S. (UL) ................................................... Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, AEx nA II T4 Canada (C-UL).......................................... Class I, Division 2, Groups A, B, C, D, T4; Class I, Zone 2, Ex nA II T4 Europe (DEMKO) ................................. EEx nA II T4 Operating temperature ............................ -40 to 70 °C (meets IEC 60068-2-1, IEC 60068-2-2) Note: To meet this operating temperature range, follow the guidelines in the installation instructions for your CompactRIO system. Storage temperature................................ -40 to 85 °C (meets IEC 60068-2-1, IEC 60068-2-2) Ingress protection ............................... IP 40 Operating humidity ............................. 10 to 90% RH, noncondensing (meets IEC 60068-2-56) Storage humidity................................. 5 to 95% RH, noncondensing (meets IEC 60068-2-56) Maximum altitude............................... 2,000 m Pollution degree.................................. 2 (meets IEC 60664) Shock and Vibration To meet these specifications, you must panel mount the CompactRIO system, affix ferrules to the ends of the terminal wires, and install a tie wrap on the USB cable for strain relief. You can use the tie wrap to attach the USB cable to the Ethernet cable. Operating vibration, random............... 5 grms, 10 to 500 Hz (meets IEC 60068-2-64) Operating shock .................................. 30 g, 11 ms half sine 50 g, 3 ms half sine, 18 shocks at 6 orientations (meets IEC 60068-2-27) Operating vibration, sinusoidal........... 5 g, 10 to 500 Hz (meets IEC 60068-2-6) BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.) 3 NI Services and Support NI has the services and support to meet your needs around the globe and through the application life cycle – from planning and development through deployment and ongoing maintenance. We offer services and service levels to meet customer requirements in research, design, validation, and manufacturing. Visit ni.com/services. Training and Certification NI training is the fastest, most certain route to productivity with our products. NI training can shorten your learning curve, save development time, and reduce maintenance costs over the application life cycle. We schedule instructor-led courses in cities worldwide, or we can hold a course at your facility. We also offer a professional certification program that identifies individuals who have high levels of skill and knowledge on using NI products. Visit ni.com/training. Professional Services Our Professional Services Team is composed of NI applications engineers, NI Consulting Services, and a worldwide National Instruments Alliance Partner program of more than 600 independent consultants and integrators. Services range from start-up assistance to turnkey system integration. Visit ni.com/alliance. OEM Support We offer design-in consulting and product integration assistance if you want to use our products for OEM applications. For information about special pricing and services for OEM customers, visit ni.com/oem. ni.com • 800 813 3693 National Instruments • [email protected] Local Sales and Technical Support In offices worldwide, our staff is local to the country, giving you access to engineers who speak your language. NI delivers industry-leading technical support through online knowledge bases, our applications engineers, and access to 14,000 measurement and automation professionals within NI Developer Exchange forums. Find immediate answers to your questions at ni.com/support. We also offer service programs that provide automatic upgrades to your application development environment and higher levels of technical support. Visit ni.com/ssp. Hardware Services NI Factory Installation Services NI Factory Installation Services (FIS) is the fastest and easiest way to use your PXI or PXI/SCXI combination systems right out of the box. Trained NI technicians install the software and hardware and configure the system to your specifications. NI extends the standard warranty by one year on hardware components (controllers, chassis, modules) purchased with FIS. To use FIS, simply configure your system online with ni.com/pxiadvisor. Calibration Services NI recognizes the need to maintain properly calibrated devices for high-accuracy measurements. We provide manual calibration procedures, services to recalibrate your products, and automated calibration software specifically designed for use by metrology laboratories. Visit ni.com/calibration. Repair and Extended Warranty NI provides complete repair services for our products. Express repair and advance replacement services are also available. We offer extended warranties to help you meet project life-cycle requirements. Visit ni.com/services. *351489A-01* 351489A-01 © 2007 National Instruments Corporation. All rights reserved. CompactRIO, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, and SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies. A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI. 2007-8739-161-101-D