NI NICRIO-9012

CompactRIO High-Performance Real-Time Controllers
NI cRIO-9012, NI cRIO-9014 NEW!
• Small and rugged embedded
real-time controllers
• Execution target for NI LabVIEW
Real-Time applications
• Reliable and deterministic operation
for stand-alone control, monitoring,
and logging
• 400 MHz Freescale MPC5200
real-time processor
• -40 to 70 °C operating
temperature range
Product
cRIO-9012
cRIO-9014
Operating System
• LabVIEW Real-Time (VxWorks)
Driver Software
• NI-RIO for reconfigurable
embedded systems
DRAM
Memory
(MB)
Internal
Nonvolatile
Storage (MB)
10/100BaseT/TX
Ethernet Port
RS232
Serial
Port
USB
Port
64
128
128
2000
LEDs
DIP
Switches
Power Supply
Input Range
Power
Consumption
Backup
Power
Input
Remote Panel
Web Server
FTP
Server
4
4
5
5
9 to 35 VDC
9 to 35 VDC
6 W max
6 W max
Overview and Applications
Embedded Software
The National Instruments cRIO-901x controllers feature an industrial
400 MHz Freescale MPC5200 real-time processor for deterministic
and reliable real-time applications. Both embedded controllers
are designed for extreme ruggedness, reliability, and low power
consumption with dual 9 to 35 VDC supply inputs that deliver isolated
power to the CompactRIO chassis/modules and a -40 to 70 °C operating
temperature range. The cRIO-901x controllers accept 9 to 35 VDC power
supply inputs on power-up and 6 to 35 VDC power supply inputs during
operation, so they can function for long periods of time in remote
applications using a battery or solar power.
With the 10/100 Mb/s Ethernet and serial ports, you can
communicate via TCP/IP, UDP, Modbus/TCP, and serial protocols. The
cRIO-901x controllers also feature built-in Web (HTTP) and file (FTP)
servers. For additional storage capability, cRIO-901x controllers have a
full-speed USB host port to which you can connect external USB-based
storage media (flash drives and hard drives) for embedded logging
applications requiring additional storage. Also, there is a fault-tolerant
file system embedded in cRIO-901x controllers that provides increased
reliability for data logging.
CompactRIO real-time controllers connect to any 4 or 8-slot
cRIO-910x reconfigurable chassis. The embedded FPGA in the chassis
controls each I/O module and passes data to the controller through
a local PCI bus using built-in communications functions.
The cRIO-901x controllers run the National Instruments
LabVIEW Real-Time Module on the Wind River VxWorks real-time
operating system (RTOS) for extreme reliability and determinism.
You can now use the leading VxWorks RTOS technology to quickly
design, prototype, and deploy a customizable COTS embedded
system using NI LabVIEW graphical programming tools.
Ordering Information
NI cRIO-9012 ........................................................................779563-01
NI cRIO-9014 ........................................................................ 779564-01
Accessories
NI 9978 (4-pos screw-terminal power supply plugs,
quantity 5)..........................................................................196938-01
NI 9979 (strain relief kit for 4-pos power connector) ..........196939-01
BUY NOW!
For complete product specifications, pricing, and accessory
information, call 800 813 3693 (U.S.) or go to ni.com/compactrio.
CompactRIO High-Performance Real-Time Controllers
Power Requirements
Specifications
Caution: You must use a National Electric Code (NEC) UL Listed Class 2
power supply with cRIO-901x controllers.
Minimum Software Support Information
CompactRIO
Real-Time Controller
Minimum Version of LabVIEW
Real-Time Module
Minimum Version
of NI-RIO Driver
8.2
8.2.1
2.1
2.1.3
cRIO-9012
cRIO-9014
Specifications subject to change without notice. The following
specifications are typical for the range -40 to 70 °C unless
otherwise noted.
Network
Network interface ................................... 10BaseT and 100BaseTX Ethernet
Compatibility ....................................... IEEE 802.3
Communication rates.......................... 10 Mb/s, 100 Mb/s,
autonegotiated
Maximum cabling distance................. 100 m/segment
SMB Connector
Output Characteristics
Logic high............................................
Logic low.............................................
Driver type...........................................
Sink/source current.............................
3-state output leakage current ...........
3.3 V
0V
CMOS
±50 mA
±5 µA
20 W
9 to 35 V
6 to 35 V
Note: The cRIO-901x controllers are guaranteed to power up when 9 V
is applied to V and C. After power-up, it can operate on as little as 6 V.
Physical Characteristics
If you need to clean the controller, wipe it with a dry towel.
Screw-terminal wiring ........................ 12 to 24 AWG copper conductor
wire with 10 mm (0.39 in.) of
insulation stripped from the end
Torque for screw terminals.................... 0.5 to 0.6 N · m (4.4 to 5.3 lb · in.)
Weight................................................. Approx. 488 g (17.2 oz)
Measurement Category I is for measurements performed on circuits not
directly connected to the electrical distribution system referred to as
MAINS voltage. MAINS is a hazardous live electrical supply system
that powers equipment. This category is for measurements of voltages
from specially protected secondary circuits. Such voltage measurements
include signal levels, special equipment, limited-energy parts of
equipment, circuits powered by regulated low-voltage sources,
and electronics.
-500 mV
990 mV
2.31 V
5.5 V
2.5 pF
1 kΩ to 3.3 V
Caution: Do not connect to signals or use for measurements within
measurement categories II, III, or IV.
Maximum data rate ............................ 12 Mb/s
Maximum current................................ 500 mA
cRIO-9012
cRIO-9014
6W
Connect only voltages that are within these limits.
V-to-C .................................................. 35 V max,
Measurement Category I
USB Port
CompactRIO
Real-Time Controller
48 W secondary, 18 to 24 VDC
Safety Voltages
Input Characteristics
Minimum input level...........................
Maximum input low level ...................
Minimum input high level...................
Maximum input level ..........................
Input capacitance................................
Resistive strapping .............................
Recommended power supply..............
Power consumption
Controller only ................................
Controller supplying power to
eight CompactRIO modules........
Power supply
On power-up ...................................
After power-up ...............................
Safety Standards
Nonvolatile Storage
DRAM
128 MB
2 GB
64 MB
128 MB
Memory
Use the following formula to determine the minimum life span in years
of the nonvolatile storage of your cRIO-901x controller:
Minimum life span in years = [Amount of memory in controller (MB) x
100,000 / 365 days] / [file size (MB) x write rate (per day)]
This product is designed to meet the requirements of the following
standards of safety for electrical equipment for measurement, control,
and laboratory use:
• IEC 61010-1, EN 61010-1
• UL 61010-1, CSA 61010-1
Note: For UL and other safety certifications, refer to the product label or
visit ni.com/certification, search by model number or product line, and
click the appropriate link in the Certification column.
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
2
CompactRIO High-Performance Real-Time Controllers
Electromagnetic Compatibility
Environmental
This product is designed to meet the requirements of the following
standards of EMC for electrical equipment for measurement, control,
and laboratory use:
The cRIO-901x controllers are intended for indoor use only. For outdoor
use, mount the CompactRIO system in a suitably rated enclosure.
• EN 61326 EMC requirements; Industrial Immunity
• EN 55011 Emissions; Group 1, Class A
• CE, C-Tick, ICES, and FCC Part 15 Emissions; Class A
Note: For EMC compliance, operate this device according to
product documentation.
CE Compliance
This product meets the essential requirements of applicable European
Directives, as amended for CE marking, as follows:
• 73/23/EEC; Low-Voltage Directive (safety)
• 89/336/EEC; Electromagnetic Compatibility Directive (EMC)
Note: Refer to the Declaration of Conformity (DoC) for this product for
any additional regulatory compliance information. To obtain the DoC for
this product, visit ni.com/certification, search by model number or
product line, and click the appropriate link in the Certification column.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers: At the end of their life cycle, all products must be sent
to a WEEE recycling center. For more information about WEEE recycling
centers and National Instruments WEEE initiatives, visit
ni.com/environment/weee.htm.
Hazardous Locations
U.S. (UL) ................................................... Class I, Division 2, Groups A, B, C,
D, T4; Class I, Zone 2, AEx nA II T4
Canada (C-UL).......................................... Class I, Division 2, Groups A, B, C,
D, T4; Class I, Zone 2, Ex nA II T4
Europe (DEMKO) ................................. EEx nA II T4
Operating temperature ............................ -40 to 70 °C (meets IEC 60068-2-1,
IEC 60068-2-2)
Note: To meet this operating temperature range, follow the guidelines in
the installation instructions for your CompactRIO system.
Storage temperature................................ -40 to 85 °C (meets IEC 60068-2-1,
IEC 60068-2-2)
Ingress protection ............................... IP 40
Operating humidity ............................. 10 to 90% RH, noncondensing
(meets IEC 60068-2-56)
Storage humidity................................. 5 to 95% RH, noncondensing
(meets IEC 60068-2-56)
Maximum altitude............................... 2,000 m
Pollution degree.................................. 2 (meets IEC 60664)
Shock and Vibration
To meet these specifications, you must panel mount the CompactRIO
system, affix ferrules to the ends of the terminal wires, and install a tie
wrap on the USB cable for strain relief. You can use the tie wrap to attach
the USB cable to the Ethernet cable.
Operating vibration, random............... 5 grms, 10 to 500 Hz
(meets IEC 60068-2-64)
Operating shock .................................. 30 g, 11 ms half sine 50 g,
3 ms half sine, 18 shocks at
6 orientations
(meets IEC 60068-2-27)
Operating vibration, sinusoidal........... 5 g, 10 to 500 Hz
(meets IEC 60068-2-6)
BUY ONLINE at ni.com or CALL 800 813 3693 (U.S.)
3
NI Services and Support
NI has the services and support to meet
your needs around the globe and through
the application life cycle – from planning
and development through deployment
and ongoing maintenance. We offer
services and service levels to meet
customer requirements in research,
design, validation, and manufacturing.
Visit ni.com/services.
Training and Certification
NI training is the fastest, most certain route to productivity with our
products. NI training can shorten your learning curve, save development
time, and reduce maintenance costs over the application life cycle. We
schedule instructor-led courses in cities worldwide, or we can hold a
course at your facility. We also offer a professional certification program
that identifies individuals who have high levels of skill and knowledge on
using NI products. Visit ni.com/training.
Professional Services
Our Professional Services Team is composed of NI applications engineers,
NI Consulting Services, and a worldwide National Instruments Alliance
Partner program of more than 600 independent consultants and
integrators. Services range from
start-up assistance to turnkey
system integration.
Visit ni.com/alliance.
OEM Support
We offer design-in consulting and product integration assistance if you
want to use our products for OEM applications. For information about
special pricing and services for OEM customers, visit ni.com/oem.
ni.com • 800 813 3693
National Instruments • [email protected]
Local Sales and Technical Support
In offices worldwide, our staff is local to the country, giving you access
to engineers who speak your language. NI delivers industry-leading
technical support through online knowledge bases, our applications
engineers, and access to 14,000 measurement and automation
professionals within NI Developer Exchange forums. Find immediate
answers to your questions at ni.com/support.
We also offer service programs that provide automatic upgrades to
your application development environment and higher levels of technical
support. Visit ni.com/ssp.
Hardware Services
NI Factory Installation Services
NI Factory Installation Services (FIS) is the fastest and easiest way to
use your PXI or PXI/SCXI combination systems right out of the box.
Trained NI technicians install the software and hardware and configure
the system to your specifications. NI extends the standard warranty by
one year on hardware components (controllers, chassis, modules)
purchased with FIS. To use FIS, simply configure your system online
with ni.com/pxiadvisor.
Calibration Services
NI recognizes the need to maintain properly calibrated devices for
high-accuracy measurements. We provide manual calibration
procedures, services to recalibrate your products, and automated
calibration software specifically designed for use by metrology
laboratories. Visit ni.com/calibration.
Repair and Extended Warranty
NI provides complete repair services for our products. Express repair
and advance replacement services are also available. We offer
extended warranties to help you meet project life-cycle requirements.
Visit ni.com/services.
*351489A-01*
351489A-01
© 2007 National Instruments Corporation. All rights reserved. CompactRIO, LabVIEW, National Instruments, National Instruments Alliance Partner, NI, ni.com, and
SCXI are trademarks of National Instruments. Other product and company names listed are trademarks or trade names of their respective companies.
A National Instruments Alliance Partner is a business entity independent from NI and has no agency, partnership, or joint-venture relationship with NI.
2007-8739-161-101-D