AIMTEC AM4TW-2412D-RVZ

Series AM4TW-RVZ
4 Watt | DC-DC Converter
FEATURES:
Models
Single output
Model
AM4TW-2403S-RVZ
AM4TW-2405S-RVZ
AM4TW-2412S-RVZ
AM4TW-2415S-RVZ
AM4TW-4803S-RVZ
AM4TW-4805S-RVZ
AM4TW-4812S-RVZ
AM4TW-4815S-RVZ
Models
Dual output
Model
AM4TW-2405D-RVZ
AM4TW-2412D-RVZ
AM4TW-2415D-RVZ
AM4TW-4805D-RVZ
AM4TW-4812D-RVZ
AM4TW-4815D-RVZ
•
•
•
•
Output Voltage
(V)
Output Current
max (mA)
Input Voltage
(V)
Output Voltage
(V)
Output Current
max (mA)
9-36
9-36
9-36
9-36
18-72
18-72
18-72
18-72
Parameters
Voltage Range
Filter
Start up time
Peak Input Voltage time
Absolute Max Rating
Isolation Specifications
Parameters
Output Specifications
Parameters
Voltage Balance
Voltage accuracy
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
www.aimtec.com
F 051e R13.B
Operating temperature -40oC to + 85oC
Input / Output isolation 1500 VDC
Pin compatible with multiple manufacturers
Continuous short circuit protection
•
•
•
•
Input Voltage
(V)
Input Specifications
Tested I/O voltage
Resistance
Capacitance
Wide Input Range (4:1)
24 Pin DIP Package
Metal package
High efficiency up to 75%
9-36
9-36
9-36
18-72
18-72
18-72
3.3
5
12
15
3.3
5
12
15
±5
±12
±15
±5
±12
±15
1000
800
333
266
1000
800
333
266
±400
±166
±133
±400
±166
±133
Nominal
Typical
24 Vin
20
15
-0.7-40
24
48
Conditions
At 20MHz Bandwidth
±0.5
±0.5
±0.02
60
Maximum
Continuous
Auto Recovery
Tel: +1 514 620 2722
1 of 3
Efficiency
(%)
66
71
74
74
66
72
73
74
Efficiency
(%)
70
72
75
70
72
73
Units
VDC
Ms
Ms
VDC
1500
Typical
±1
±1
±470
±100
±68
±470
±100
±68
Rated
> 1000
60
Balanced Load
Capacitive load,
max (μF)
π (Pi) Network
Typical
3 sec
1000
1000
320
220
1000
1000
320
220
Maximum
9-36
18-72
Conditions
Capacitive load,
max (μF)
Units
VDC
MOhm
pF
Units
%
%
%
%
%/oC
mV p-p
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4TW-RVZ
4 Watt | DC-DC Converter
General Specifications
Parameters
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions(L x W x H)
MTBF
Conditions
100% load
Full Load (see derating chart)
Typical
100-400
Maximum
-40 to +85
-40 to +125
Free air convection
100
Units
KHz
o
C
o
C
o
C
95
%
Nickel coated copper
15
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.8 x 0.4 inches
31.75 x 20.32 x 10.16 mm
>2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Pin
2
3
9
11
14
16
22
23
Single
-V Input
-V Input
No pin
N.C.
+V Output
-V Output
+V Input
+V Input
www.aimtec.com
F 051e R13.B
1500 VDC
Dual
-V Input
-V Input
Common
-V Output
+V Output
Common
+V Input
+V Input
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM4TW-RVZ
4 Watt | DC-DC Converter
Dimensions
22.86
(0.90)
0.50
(0.02)
20.32
(0.80)
2
3
9
11
15.24
(0.60)
31.75
(1.25)
Bottom View
23 22
16
14
5.08
(0.20)
2.54
(0.10)
Built-in Stand-offs to
ease PCB cleaning
3.05
(0.12)
10.16
(0.40)
Printed Face
Derating
Free Air Convection
85 º C
Output Power %
100
80
60
Safe Operating Area
40
20
0
-40
0
25
50
75
85
100
Ambient Temperature º C
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only