AIMTEC AM6TW

Series AM6TW-VZ
6 Watt | DC-DC Converter
FEATURES:








Wide Input Range (4:1)
24 Pin DIP Package
Metal package
High efficiency up to 79%
Operating temperature -40oC to + 85oC
Input / Output isolation 1500 or 3500VDC
Pin compatible with multiple manufacturers
Continuous short circuit protection
Models
Single output
Input Voltage
(V)
Output Voltage
(V)
AM6TW-2412S-VZ
AM6TW-2415S-VZ
AM6TW-4812S-VZ
AM6TW-4815S-VZ
9-36
9-36
18-72
18-72
12
15
12
15
AM6TW-2412SH35-VZ
AM6TW-2415SH35-VZ
AM6TW-4812SH35-VZ
AM6TW-4815SH35-VZ
9-36
9-36
18-72
18-72
12
15
12
15
Input Voltage
(V)
Output Voltage
(V)
9-36
9-36
18-72
18-72
9-36
9-36
18-72
18-72
±12
±15
±12
±15
±12
±15
±12
±15
Model
Output Current
max (mA)
Capacitive load,
max (μF)
Efficiency
(%)
470
470
470
470
470
470
470
470
75
77
77
77
75
77
77
77
Capacitive load,
max (μF)
Efficiency
(%)
±220
±220
±220
±220
±220
±220
±220
±220
79
79
75
77
79
79
75
77
500
400
500
400
500
400
500
400
Models
Dual output
Model
AM6TW-2412D-VZ
AM6TW-2415D-VZ
AM6TW-4812D-VZ
AM6TW-4815D-VZ
AM6TW-2412DH35-VZ
AM6TW-2415DH35-VZ
AM6TW-4812DH35-VZ
AM6TW-4815DH35-VZ
Output Current
max (mA)
±250
±200
±250
±200
±250
±200
±250
±200
Input Specifications
Parameters
Voltage Range
Nominal
Typical
24
48
9-36
18-72
24 Vin
48 Vin
20
15
-0.7-40
-0.7-80
Units
VDC
 (Pi) Network
Filter
Start up time
Peak Input Voltage time
Absolute Max Rating
Maximum
Ms
Ms
VDC
Isolation Specifications
Parameters
Tested I/O voltage
Resistance
Capacitance
www.aimtec.com
F 051e R13.B
Conditions
Typical
3 sec
> 1000
60
Tel: +1 514 620 2722
1 of 3
Rated
Units
1500 (3500 H35
Model)
VDC
MOhm
pF
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6TW-VZ
6 Watt | DC-DC Converter
Output Specifications
Parameters
Voltage Balance
Voltage accuracy
Short circuit protection
Short circuit restart
Line voltage regulation
Load voltage regulation
Temperature coefficient
Ripple & Noise
Conditions
Typical
Balanced Load
±1
±1
Maximum
Units
%
%
Continuous
Auto Recovery
±0.5
±0.5
±0.02
60
At 20MHz Bandwidth
%
%
%/oC
mV p-p
General Specifications
Parameters
Conditions
Typical
Switching frequency
Operating temperature
Storage temperature
Max Case temperature
Cooling
Humidity
Case material
Weight
Dimensions(L x W x H)
MTBF
100% load
Full Load (see derating chart)
100-400
Maximum
Units
100
KHz
o
C
o
C
o
C
-40 to +85
-40 to +125
Free air convection
95
%
Nickel coated copper
15
g
Tolerance ±0.5 mm or ±0.02 inches
1.25 x 0.8 x 0.4 inches
31.75 x 20.32 x 10.16 mm
>2,200,000 hrs (MIL-HDBK -217F, Ground Benign, t=+25oC)
Safety Specifications
Parameters
Standards
Designed to meet IEC 60950-1
NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at
rated output load unless otherwise specified.
Pin Out Specifications
Pin
1
2
3
9
10
11
12/13
14
15
16
22
23
24
1500VDC
Dual
Single
Dual
+V Input
N.C.
N.C.
No pin
-V Output
+V Output
-V Input
+V Output
-V Output
No pin
N.C.
N.C.
+V Input
+V Input
-V Output
Common
No pin
Common
+V Output
-V Input
+V Output
Common
No pin
Common
-V Output
+V Input
No pin
-V Input
-V Input
No pin
No pin
N.C.
No pin
+V Output
No pin
-V Output
+V Input
+V Input
No pin
No pin
-V Input
-V Input
Common
No pin
-V Output
No pin
+V Output
No pin
Common
+V Input
+V Input
No pin
www.aimtec.com
F 051e R13.B
3500VDC
Single
Tel: +1 514 620 2722
2 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only
Series AM6TW-VZ
6 Watt | DC-DC Converter
Dimensions
Derating
NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled
by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the
date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%,
nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components
and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This
product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate
specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com.
www.aimtec.com
F 051e R13.B
Tel: +1 514 620 2722
3 of 3
Toll free: + 1 888 9 AIMTEC
(924 6832)
North America only