Series AM30K-NZ 30 Watt | DC-DC Converter FEATURES: • • • • RoHS compliant Remote On/Off control High Efficiency up to 90% Input Under voltage protection • • • • Trim adjustment Power modules for PCB mounting Operating temperature range: -40 to +85ºC Standard package Models Single output Model Input Voltage (V) Output Voltage (V) 9 – 18 9 – 18 9 – 18 9 – 18 9 – 18 18 – 36 18 – 36 18 – 36 18 – 36 18 – 36 36 – 75 36 – 75 36 – 75 36 – 75 36 – 75 3.3 5 12 15 24 3.3 5 12 15 24 3.3 5 12 15 24 AM30K-1203S-NZ AM30K-1205S-NZ AM30K-1212S-NZ AM30K-1215S-NZ AM30K-1224S-NZ AM30K-2403S-NZ AM30K-2405S-NZ AM30K-2412S-NZ AM30K-2415S-NZ AM30K-2424S-NZ AM30K-4803S-NZ AM30K-4805S-NZ AM30K-4812S-NZ AM30K-4815S-NZ AM30K-4824S-NZ Output Current max (A) 6 6 2.5 2 1.25 6 6 2.5 2 1.25 6 6 2.5 2 1.25 Maximum capacitive load (µF) 19500 10200 3240 1100 900 19500 10200 3240 1100 900 19500 10200 3240 1100 900 Efficiency (%) 85 87 88 88 88 86 88 89 89 88 87 89 90 90 90 NOTE: All specifications in this datasheet are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. Input Specifications Parameters Voltage range Filter Start up time Absolute Maximum Rating Peak Input Voltage time Remote On/Off Control Under Voltage protection Isolation Specifications Parameters Tested I/O voltage Resistance Capacitance www.aimtec.com F 051e R8.G Nominal Typical 12 24 48 9-18 18-36 36-75 π(Pi) Network 25 Maximum Units VDC ms 20 40 VDC 80 100 ms 3.5 to 12VDC or open circuit 0 to 1.2VDC or short circuit between pin 2 and 3 8 16 VDC 33 12 Vin 24 Vin 48 Vin On Off 9-18 Vin OFF 18-36 Vin OFF 36-75 Vin OFF Conditions Typical 60 sec At 500Vdc 100KHz / 1V >1000 1000 Tel: +1 514 620 2722 1 of 3 Rated 1500 Units VDC MOhm pF Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-NZ 30 Watt | DC-DC Converter Output Specifications Parameters Conditions Voltage accuracy Line voltage regulation Load voltage regulation Short Circuit protection Short Circuit restart Over current protection Temperature coefficient Ripple & Noise Transient Response Recovery Time Transient response overshoot Voltage adjustment range Input Voltage Range 20MHZ Bandwidth 25% load step change Parameters Conditions Switching frequency Operating temperature Storage temperature Case temperature Cooling Humidity Case material Weight Dimensions (L X W X H) MTBF % %/oC mV p-p μs % of Vout % Maximum -40 to +85 -55 to +105 Copper, Nickel Plated 45 2.00 x 1.60 x 0.42 inches >1 000 000 hrs Tolerance ±0.5mm % % of Vin % ±5 Free air convection Units 95 KHz o C o C o C 95 % g 50.80 x 40.60 x 10.60 mm Dimensions 50.80 (2.00) 2 6 45.72 (1.80) 2.54 (0.10) Dimensions mm (inch) Case Tolerance ±0.50 (±0.02) Pin Pitch Tolerance ±0.35 (±0.014) 4.10 (0.16) 11.80 (0.47) 5 3 2.54 (0.10) Printed Face 4 Bottom View 10.16 (0.40) 1 5.10 10.16 (0.20) (0.40) 7.62 10.16 5.08 (0.30) (0.40) (0.20) 40.60 (1.60) Single +V Input -V Input On/Off Control +V Output -V Output Trim 300 Units 160 Typical 100% load With derating above +71°C Pin Out Specifications 1 2 3 4 5 6 Maximum ±1 ±0.2 ±0.5 Continuous Auto Recovery >120 0.02 100 200 ±2 ±10 LL-HL 10% to 100% Load General Specifications Pin Typical Ø 1.50 (0.06) www.aimtec.com F 051e R8.G Tel: +1 514 620 2722 2 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only Series AM30K-NZ Trimming 30 Watt | DC-DC Converter Derating Free Air Convection 71ºC Output Power (%) 100 80 Safe Operating Area 60 40 20 0 - 40 - 20 0 20 40 60 80 85 100 Ambient Temperature º C Recommended EMI Filtering (if required by end application) Note: should your application not require filtering, no additional circuits are required. LCM (3.8mH) V+ Vo+ Load Input + AM30K-NZ Input V- Vo- NOTE: 1. Datasheets are updated as needed and as such, specifications are subject to change without notice. Once printed or downloaded, datasheets are no longer controlled by Aimtec; refer to www.aimtec.com for the most current product specifications. 2. Product labels shown, including safety agency certifications on labels, may vary based on the date manufactured. 3. Mechanical drawings and specifications are for reference only. 4. All specifications are measured at an ambient temperature of 25°C, humidity<75%, nominal input voltage and at rated output load unless otherwise specified. 5. Aimtec may not have conducted destructive testing or chemical analysis on all internal components and chemicals at the time of publishing this document. CAS numbers and other limited information are considered proprietary and may not be available for release. 6. This product is not designed for use in critical life support systems, equipment used in hazardous environments, nuclear control systems or other such applications which necessitate specific safety and regulatory standards other the ones listed in this datasheet. 7. Warranty is in accordance with Aimtec’s standard Terms of Sale available at www.aimtec.com. www.aimtec.com F 051e R8.G Tel: +1 514 620 2722 3 of 3 Toll free: + 1 888 9 AIMTEC (924 6832) North America only